Six-channel chiller

KRY 0℃~100℃ six-channel chiller

Cooling capacity 25kW~60kW
Circulation Pump MAX
2~25L/min 0.2~2.5bar
Temperature accuracy ±0.3℃
Power AC380V/ AC460V

KRY 0~100 six-channel chiller adopts water cooled type. The temperature of this six channels is uniform, but the flow rate and pressure are controlled independently. If your industry need to control temperature, flow rate and pressure simultaneously, LNEYA support customization for you. Its temperature control accuracy is around 0.3℃. The flow control accuracy of each channel is around 0.2L/min. The pressure control of each channel is 0.2bar~2.5bar. The centrifugal pump KRY 0~100 six-channel chiller uses can be optionally equipped with magnetic drive pump.

Six-channel chiller parameters

0°C

lowest

100°C

Highest

±0.3°C

Temperature control accuracy


Model KRY-A25W/6S KRY-A38W/6S KRY-A60W/6S
Temp Range 0℃~+100℃
Flow control accuracy/Group 2~25 L/min 2~25 L/min 2~25 L/min
Flow rate accuracy/group ±0.2L/min
Number of fuid output groups 6 groups 6 groups 6 groups
Pressure control/group 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar
Flow pressure description The unit can control the flow individually or separately. Need to control different solutions at the same time (customized)
Heating capacity 15kW 25kW 38kW
Cooling capacity 100℃ 25kW 38kW 60kW
20℃ 25kW 38kW 60kW
5℃ 18kW 27kW 42kW
Water-cooled type W @20℃ 6000L/H
DN32
9000L/H
DN40
15000L/H
DN50
Power 380V50HZ 38kW 55kW 82kW
Dimension cm 200*145*205 200*145*205 200*145*205

Temperature feedback

Temperature feedback PT100 (inlet temperature, outlet temperature)


Compressor

Highly, Mitsubishi, Panasonic and other compressors


Communication protocol

MODBUS RTU protocol RS485 interface



KRY -40℃~100℃
battery chillers

KRYZ -40℃~100℃
antifreeze cooler

KRY -40℃~100℃ Multi-channel
liquid cooling chiller

You can trust lneya chiller units

Global service

30,000 +customers.
20+ countries.

Certification patents

CE ,SGS, ISO certification.

After-sales service

24/7 solutions.1 year warranty

Professional team

15+ years experience.

Quality control

Quality test.

FAQ About Six-Channel Chiller

In present, there are two methods for controlling flow rate and pressure in the market. One is to adjust the main path and bypass through a proportional valve, and the other is to control the variable frequency pump through a frequency converter. The proportional valve adjustment is generally applied in the normal temperature section and high-temperature section. This method is suitable for cases where the required response time is long, the flow control accuracy is not high (around 0.3L/min). If high-precision control, short response time and low-temperature resistance are required, the general proportional valve spool can not meet the requirements. The cost of imported high-precision proportional valves is high, and they are prone to leakage at low temperatures. The adjustment method of controlling the variable frequency pump through a frequency converter avoids the defects of the proportional valve.

When purchasing a multi-channel chiller, it is necessary to evaluate various technical indicators, safety performance and subsequent service guarantees based on the specific application requirements and conditions.

*
*