Maintenance knowledge of high and low temperature constant temperature circulation device
The high and low temperature constant temperature circulation device is one of the more common equipments in the temperature control system. A good equipment is inseparable from daily maintenance. So how much do you know about maintenance?
High and low temperature constant temperature circulation device The entire liquid circulation is closed, with an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, but are mechanically connected, regardless of whether the temperature of the liquid circulation is high temperature or low temperature expansion in the container The medium is below 60 degrees.
High and low temperature constant temperature circulation device, no water vapor absorption at low temperature, no oil mist at high temperature, heat transfer oil can have a wide working temperature; mechanical and electronic valves are not used in the whole circulation system. When opening or closing the test object from the box, the article shall not be in contact with the door sealing strip. If the compressor is cooled by air cooling, the condenser fan shall be regularly inspected and the condenser shall be decontaminated and dedusted.

Due to the different cleanliness levels of the high and low temperature constant temperature circulation device, many small particles such as dust will be condensed on the evaporator under the forced air circulation, so we must clean the evaporator regularly. The humidifier fouling easily causes the humidifier to dry and may burn the humidifier, so the water circuit and the humidifier must be cleaned regularly. At the end of each experiment, it is recommended to clean the test chamber with clean water to keep the equipment clean. After the cabinet is cleaned, the cabinet should be dried to keep the cabinet dry. After the completion of each test, the temperature is set near the ambient temperature, and the power is turned off after about 30 minutes of work, and the wall of the working chamber is wiped clean.
LNEYA high and low temperature constant temperature circulation equipment professional manufacturer, producing various types of high and low temperature one machine, can also design and manufacture various non-standard products according to customer needs.
Related recommendations
-
Battery test cooling device Chiller common configuration instructions
1308Under normal use, the battery test cooling device Chiller needs to be discovered in time when any part of the abnormality occurs. This requires a clear understanding of the basic configuration of the battery test cooling device Chiller. The batter...
View details -
Application of refrigeration and heating temperature control system in chemical synthesis
906chemical synthesis cooling heating system temperature control unit
View details -
Organic waste gas recovery unit refrigeration oil requirements description
1364The organic waste gas recovery device is slightly different for different gases. The LNEYA organic waste gas recovery device and the vocs gas condensation recovery device are operated by the principles of condensation and adsorption. The refrigera...
View details -
Temperature conditions of new energy vehicle batteries
895When automobile manufacturers continue to improve battery life to overcome the driver's mileage anxiety, the energy density of the large batteries installed is also gradually increasing, which means that the temperature monitoring function of the...
View details