Organic waste gas recovery unit refrigeration oil requirements description
The organic waste gas recovery device is slightly different for different gases. The LNEYA organic waste gas recovery device and the vocs gas condensation recovery device are operated by the principles of condensation and adsorption. The refrigeration oil is also important, then the refrigeration oil has What is the requirement?
The cloud point of the frozen oil of the organic waste gas recovery device refers to the temperature at which the paraffin is precipitated in the frozen oil and the lubricating oil becomes turbid when the temperature is lowered to a certain value. The cloud point of the refrigeration oil used in the device should be lower than the evaporation temperature of the refrigerant, otherwise it will cause the throttle valve to block or affect the heat transfer performance.
The temperature at which the frozen oil is cooled under experimental conditions to stop flowing is referred to as the freezing point. The freezing point of the frozen oil used in the organic waste gas recovery device should be as low as possible (such as R22 compressor, the refrigeration oil should be below -55 °C), otherwise it will affect the flow of the refrigerant and increase the flow resistance, resulting in poor heat transfer. as a result of.

An important parameter in the characteristics of the oil viscosity of the refrigerating oil. Different refrigerants should be used to select different refrigerating oils. If the viscosity of the frozen oil is too large, the mechanical friction power, friction heat and starting torque will increase. On the other hand, if the viscosity is too small, the desired oil film cannot be formed between the moving parts, so that the desired lubrication and cooling effect cannot be achieved.
The flash point of a frozen oil is the temperature at which the lubricating oil is heated to the point where it is ignited when it comes into contact with the flame. The flash point of the frozen oil used in the organic waste gas recovery device must be 15 to 30 ° C higher than the exhaust gas temperature to avoid burning and coking of the lubricating oil. Organic waste gas recovery devices such as chemical stability and oxidation resistance, moisture and mechanical impurities, and insulation properties.
As far as the current environmental protection trend is concerned, if the company has organic waste gas, it is recommended to buy an organic waste gas recovery device for gas treatment as soon as possible to avoid troubles.
Related recommendations
-
Small coup to deal with ice blockage of high and low temperature liquid circulating chillers
806In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams. In the pip...
View details -
How to remove ultra-low temperature refrigerator shell and tube condenser scale?
1102Low-temperature refrigerator ultra-low temperature condenser scale removal In general, we have three methods, namely mechanical descaling, chemical pickling and descaling, and electronic magnetic water separator descaling. Low-temperature refriger...
View details -
The Application of Industrial Chillers
927The chiller machine is needed in a lot of industries, basically chemical, medical, pharmaceutical industries are involved, then what industry can Wuxi Lneya chiller meet in the end? It is known that we are one of the top chiller manufacturers. Th...
View details -
Selection of ultra-low temperature chiller supporting the glass reactor
982In order to achieve an economical ultra-low temperature environment for glass reactors, many customers will not choose multi-stage compressor refrigeration equipment with more than two stages, but use liquid nitrogen. The cost of liquid nitrogen...
View details