SUNDI series – Industrial Chillers Manufacturer Supplier – LNEYA https://www.lneya.com Air Cooling Chiller and Water Cooling Chiller Type Thu, 25 Apr 2024 03:22:29 +0000 en-US hourly 1 https://wordpress.org/?v=6.4.3 https://www.lneya.com/wp-content/uploads/2023/05/Lneya-logo-e1683777581854-150x137.png SUNDI series – Industrial Chillers Manufacturer Supplier – LNEYA https://www.lneya.com 32 32 SUNDI-320/420W/430W https://www.lneya.com/special-chiller/chiller-refrigeration-system-sundi-320-420w-430w.html https://www.lneya.com/special-chiller/chiller-refrigeration-system-sundi-320-420w-430w.html#comments Wed, 17 May 2023 07:53:09 +0000 https://www.lneya.com/special-chiller/chiller-refrigeration-system-sundi-320-420w-430w.html
SUNDI-320/420W/430W
SUNDI-320/420W/430W
SUNDI-320/420W/430W
SUNDI-320/420W/430W
SUNDI-320/420W/430W

SUNDI-320/420W/430W

Temperature control of reactor and material
  • Cooling capacity0.3kW~3kW
  • Heating Power2kW~3kW
  • Power range2.9kW~5kW
  • Medium accuracy±0.5℃
  • Material accuracy±1℃
  • RefrigerantR404A/R507C
  • Weight55KG~85KG

Product data download

Dynamic Cooling Heating System

Fully enclosed system, single medium completes refrigeration and heating

Control temperature

Temperature Accuracy

Configuration Details

Model SUNDI-320 SUNDI-420W SUNDI-430W
Temp. range -30℃~180℃ -40℃~180℃ -40℃~200℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100
Temp. feedback The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power 2KW 2KW 3KW
Cooling capacity 180℃ 1.5kW 1.8kW 3kW
50℃ 1.5kW 1.8kW 3kW
0℃ 1.5kW 1.8kW 3kW
-5℃ 0.9kW 1.2kW 2kW
-20℃ 0.6kW 1kW 1.5kW
-35℃   0.3kW 0.5kW
Circulation pump Max10L/min
0.8bar
Max10L/min
0.8bar
Max20L/min
2bar
Compressor Secop/French Tecumseh Secop/French TecumsehSecop/French Tecumseh  
Expansion valve Electronic expansion valve
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C,
Connection size ZG1/2 ZG1/2 ZG1/2
Water-cooled type W(cooling water@20℃)   800L/H
1.5bar~4bar
8000L/H
1.5bar~4bar
Dimension(mm) 350*560*750 400*700*1300 470*700*1300
Positive ex-proof size(mm)   700*750*1215 700*750*1215
Weight 55kg 60kg 85kg
Power AC 220V 50HZ 2.9kW(max) AC 220V 50HZ 3.3kW(max) AC380V 50HZ  5kW(max)
Case material Cold rolled sheet spray molding (standard color 7035)
Optional   positive pressure ex-proof system add PEX at the end
Optional Optional Ethernet interface, configure the computer operating software
Optional Optional outside touch screen display controller(separated),the communication line distance is 10 meter.
Optional Power Optional power 100V 50HZ single-phase,110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ three-phase,440V~460V 60HZ three-phase
Optional The sundi series can be selected within the heating power of 25kW. The temperature control accuracy of the medium is ±0.1°C, and the temperature control accuracy of the material is ±0.1°C.

Product Description

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.


Click online message to inquire about product details
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

recommend products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/chiller-refrigeration-system-sundi-320-420w-430w.html/feed 2
SUNDI -10℃~150℃ https://www.lneya.com/special-chiller/glycol-chiller-system-sundi-10-200.html https://www.lneya.com/special-chiller/glycol-chiller-system-sundi-10-200.html#respond Wed, 17 May 2023 07:53:01 +0000 https://www.lneya.com/special-chiller/glycol-chiller-system-sundi-10-200.html
SUNDI -10℃~150℃
SUNDI -10℃~150℃
SUNDI -10℃~150℃
SUNDI -10℃~150℃
SUNDI -10℃~150℃

SUNDI -10℃~150℃

Temperature control of reactor and material
  • Cooling capacity1.5kW~15kW
  • Heating Power2.5kW~15kW
  • Power range3.6kW~20kW
  • Medium accuracy±0.5℃
  • Material accuracy±1℃
  • RefrigerantR404A/R507C
  • Weight115KG~300KG

Product data download

Product Description

Configuration Details

Model SUNDI-125
SUNDI-125W
SUNDI-135
SUNDI-135W
SUNDI-155
SUNDI-155W
SUNDI-175
SUNDI-175W
SUNDI-1A10
SUNDI-1A10W
SUNDI-1A15
SUNDI-1A15W
Temp. range -10℃~+150℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 2.5 3.5 5.5 7.5 10 15
Cooling capacity kW at 200℃ 2.5 3.5 5.5 7.5 10 15
  20℃ 2.5 3.5 5.5 7.5 10 15
  -5℃ 1.5 2.1 3.3 4.2 6 9
Circulation pump max
L/min bar
20 35 35 50 50 75
    1 1 1 1.2 1.2 1.2
Compressor Mitsubishi Mitsubishi Emerson copeland vortex flexible Emerson copeland vortex flexible Emerson copeland vortex flexible Emerson copeland vortex flexible
Expansion valve Electronic expansion valve
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1
Water-cooled type W(cooling water@20℃) 600L/H
1.5bar~4bar
800L/H
1.5bar~4bar
1000L/H
1.5bar~4bar
1200L/H
1.5bar~4bar
1600L/H
1.5bar~4bar
2000L/H
1.5bar~4bar
Dimension(water type)mm 400*700*1300 450*700*1600 450*700*1600 550*700*1750 550*700*1750 700*850*1850
Weight kg 115 165 185 235 280 300
Power AC 220V 50HZ 4kW max AC 380V 50HZ 5.6kW max

AC 380V 50HZ

8kW max

AC 380V 50HZ 10.5kW max AC 380V 50HZ 13.8kW max AC 380V 50HZ 20kW max

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Click online message to inquire about product details
Send us a message about the product
Send us a message about the product
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/glycol-chiller-system-sundi-10-200.html/feed 0
SUNDI -25℃~200℃ https://www.lneya.com/special-chiller/industrial-chiller-systems-sundi-25-200-300.html https://www.lneya.com/special-chiller/industrial-chiller-systems-sundi-25-200-300.html#comments Wed, 17 May 2023 07:52:54 +0000 https://www.lneya.com/special-chiller/industrial-chiller-systems-sundi-25-200-300.html
SUNDI  -25℃~200℃
SUNDI  -25℃~200℃
SUNDI  -25℃~200℃
SUNDI  -25℃~200℃

SUNDI -25℃~200℃

Cooling Heating System of reactor and material
  • Cooling capacity1kW~200kW
  • Heating Power2.5kW~200kW
  • Power range4kW~260kW
  • Medium accuracy±0.5℃~±1℃
  • Material accuracy±1℃~±1.5℃
  • RefrigerantR404A
  • Weight115KG~2150KG

Product data download

  • manual.pdf

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI-225
SUNDI-225W
SUNDI-235
SUNDI-235W
SUNDI-255
SUNDI-255W
SUNDI-275
SUNDI-275W
SUNDI-2A10
SUNDI-2A10W
SUNDI-2A15
SUNDI-2A15W
SUNDI-2A25
SUNDI-2A25W
SUNDI-2A38W SUNDI-2A60W SUNDI-2A95W SUNDI-2A130W SUNDI-2A200W
Temp. range -25℃~+200℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃   ±1℃
Material temp. accuracy ±1℃ ±1.5℃  
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling capacity kW at 200℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  50℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  -5℃ 2 3 4.5 6.6 8 12 19 30 46 70 80 125
  -20℃ 1 1.8 2.8 3.8 4.6 7 12 16 22 32 43 65
Circulation pump max
L/min bar
20 35 35 50 50 110 150 200 250 400 400 600
    1 1.2 1.2 1.2 1.2 1.5 1.5 1.5 2.5 2.5 2.5 2.5
Compressor Mitsubishi Emerson copeland vortex flexible Dorin seni-closed compressor
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A,optional: R448A/R125
Connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 Z G1 DN32 PN10 DN40 PN10 DN50 PN10 DN65 PN10 DN65 PN10 DN80 PN10
Water-cooled type W(cooling water@20℃) 600L/H
1.5bar~4bar
800L/H
1.5bar~4bar
1000L/H
1.5bar~4bar
1200L/H
1.5bar~4bar
1600L/H
1.5bar~4bar
2200L/H
1.5bar~4bar
6m³/H
1.5bar~4bar
10m³/H
1.5bar~4bar
14m³/H
1.5bar~4bar
20m³/H
1.5bar~4bar
28m³/H
1.5bar~4bar
36m³/H
1.5bar~4bar
Dimension(water type)cm 40*70*130 45*70*160 45*700*160 55*700*175 65*85*185 70*85*185 80*120*185 150*100*185 200*145*205 200*145*205 250*145*225 300*160*225
Weight kg 115 165 185 230 280 300 550 750 1000 1250 1580 2150
Power 380V 50HZ 4kW 5.6kW 8kW 11kW 14kW 21kW 35kW 54kW 81kW 126kW 165kW 260kW

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Send us a message about the product
Send us a message about the product
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/industrial-chiller-systems-sundi-25-200-300.html/feed 1
SUNDI -25℃~300℃ https://www.lneya.com/special-chiller/industrial-chiller-system-sundi25300.html https://www.lneya.com/special-chiller/industrial-chiller-system-sundi25300.html#respond Wed, 17 May 2023 07:52:46 +0000 https://www.lneya.com/special-chiller/industrial-chiller-system-sundi25300.html
SUNDI -25℃~300℃
SUNDI -25℃~300℃
SUNDI -25℃~300℃
SUNDI -25℃~300℃
SUNDI -25℃~300℃

SUNDI -25℃~300℃

Temperature control of reactor and material
  • Cooling capacity1kW~200kW
  • Heating Power2.5kW~200kW
  • Power range4kW~260kW
  • Medium accuracy±0.5℃~±1℃
  • Material accuracy±1℃~±1.5℃
  • RefrigerantR404A/R507C
  • Weight130KG~2250KG

Product data download

Click online message to inquire about product details
Send us a message about the thermostat
Send us a message about the thermostat
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI
-225V
SUNDI
-225WV
SUNDI
-235V
SUNDI
-235WV
SUNDI
-255V
SUNDI
-255WV
SUNDI
-275V
SUNDI
-275WV
SUNDI
-2A10V
SUNDI
-2A10WV
SUNDI
-2A15V
SUNDI
-2A15WV
SUNDI
-2A25V
SUNDI
-2A25WV
SUNDI
-2A38WV
SUNDI
-2A60WV
SUNDI
-2A95WV
SUNDI
-2A130WV
SUNDI
-2A200WV
Temp. range -25℃~+300℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication
Portocol
MODBUS RTU Protocol, RS485 interface
Material temp.
feedback
PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp.
acccuracy
±0.5℃
Material temp.
accuracy
±1℃
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling
capacity
kW at
300℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
50℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
-5℃ 2 3 4.5 6.6 8 12 19 30 46 70 80 125
-20℃ 1 1.8 2.8 3.8 4.6 7 12 16 22 32 43 65
Circulation
pump max
L/min bar
20 35 35 50 60 110 150 150 250 400 400 600
1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5
Pump magnetic drive pump
Compressor Mitsubishi Emerson copeland vortex flexible Dorin seni-closed compressor
Expansion valve Electronic expansion valve
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid
low level protection, high temperature protection and temperature fault protection.
Closed circulation
system
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,
pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 DN32 DN40 DN50 DN65 DN65 DN80
Water-cooled
type W(@20℃)
600
L/H
800
L/H
1200
L/H
1600
L/H
2400
L/H
3000
L/H
6
m³/H
10
m³/H
12
m³/H
18
m³/H
24
m³/H
36
m³/H
Dimension
(water type)cm
40
*70
*130
45
*70
*160
55
*70
*175
55
*70
*175
70
*85
*185
80
*120
*185
80
*120
*185
100
*150
*185
200
*145
*205
200
*145
*205
250
*145
*225
300
*160
*225
Weight kg 130 180 195 260 320 390 620 820 1100 1350 1680 2250
Power 380V 50HZ 4kW 6kW 8kW 11kW 14kW 21kW 34kW 52kW 79kW 123kW 165kW 260kW

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Displays Various Information:

1. Displays all the kind of process control temperatures.
2. Shows the liquid level of the heat conducting medium in the expansion vessel.
3. Shows indication for refrigeration system working.
4. Shows indication for heater working.
5. Shows indication for circulation pump working.
6. Displays the temp. control ( materials temp. control pattern, heat conducting medium temp. control ).
7. The temp. upper limit, lower limit control can be set.
8. The temp. difference between jacket & reactor material can be set.
9. Shows the alarm to add the liquid when it is empty.
10. The refrigeration compressor can be set to operate manuallyor automatically.

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/industrial-chiller-system-sundi25300.html/feed 0
SUNDI -45℃~250℃ https://www.lneya.com/special-chiller/industrial-air-chillers-sundi-45-250.html https://www.lneya.com/special-chiller/industrial-air-chillers-sundi-45-250.html#comments Wed, 17 May 2023 07:52:39 +0000 https://www.lneya.com/special-chiller/industrial-air-chillers-sundi-45-250.html
SUNDI -45℃~250℃
SUNDI -45℃~250℃
SUNDI -45℃~250℃
SUNDI -45℃~250℃
SUNDI -45℃~250℃

SUNDI -45℃~250℃

Dynamic temprature control system
  • Heating Power3.5kW~200kW
  • Cooling capacity0.45kW~200kW
  • Power range6.5kW~280kW
  • Medium accuracy±0.5℃~±1℃
  • Material accuracy±1℃~±1.5℃
  • RefrigerantR404A/R507C
  • Weight180KG~2250KG

Product data download

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI-535
SUNDI-535W
SUNDI-555
SUNDI-555W
SUNDI-575
SUNDI-575W
SUNDI-5A10
SUNDI-5A10W
SUNDI-5A15
SUNDI-5A15W
SUNDI-4A25
SUNDI-4A25W
SUNDI-4A38W SUNDI-4A60W SUNDI-4A95W SUNDI-4A130W SUNDI-4A200W
Temp. range -45℃~+250℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling capacity kW at 250℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  100℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  20℃ 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  0℃ 3 5 7 10 15 25 38 60 95 130 200
  -20℃ 1.5 2.9 4.2 6 11 16 26 34 50 70 120
  -40℃ 0.45 0.9 1.5 2 3.8 4.7 9 12 18 24 43
Circulation pump max
L/min bar
35 35 50 60 110 150 200 250 400 400 600
    1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5
Pump Magnetic drive pump Magnetic drive pump
Compressor Emerson, Danfoss, Italy Dorin,French Tecumseh.
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1 DN32 PN10 DN50 PN10 DN50 PN10 DN65 PN10 DN65 PN10 DN65 PN10
Water-cooled type W(cooling water@20℃) 1200L/H
1.5bar~4bar
1500L/H
1.5bar~4bar
1800L/H
1.5bar~4bar
2600L/H
1.5bar~4bar
3200L/H
1.5bar~4bar
7m³/H
1.5bar~4bar
10m³/H
1.5bar~4bar
15m³/H
1.5bar~4bar
20m³/H
1.5bar~4bar
32m³/H
1.5bar~4bar
42m³/H
1.5bar~4bar
Dimension cm 45*70*160 55*70*175 55*70*175 65*85*185 70*85*185 80*120*185 150*100*185 200*145*205 200-145-205 250-145-225 300*160*225
Weight kg 180 195 260 320 390 620 820 1100 1350 1680 2250
Power 380V 50HZ 6.2kW 9kW 11.5kW 16kW 23kW 37kW 55kW 85kW 130kW 178kW 280kW

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Displays Various Information:

1. Displays all the kind of process control temperatures.
2. Shows the liquid level of the heat conducting medium in the expansion vessel.
3. Shows indication for refrigeration system working.
4. Shows indication for heater working.
5. Shows indication for circulation pump working.
6. Displays the temp. control ( materials temp. control pattern, heat conducting medium temp. control ).
7. The temp. upper limit, lower limit control can be set.
8. The temp. difference between jacket & reactor material can be set.
9. Shows the alarm to add the liquid when it is empty.
10. The refrigeration compressor can be set to operate manuallyor automatically.

Click online message to inquire about product details
Send us a message about the product
Send us a message about the product
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/industrial-air-chillers-sundi-45-250.html/feed 1
SUNDI -45℃~300℃ https://www.lneya.com/special-chiller/sundi-45-300.html https://www.lneya.com/special-chiller/sundi-45-300.html#respond Wed, 17 May 2023 07:52:32 +0000 https://www.lneya.com/special-chiller/sundi-45-300.html
SUNDI -45℃~300℃
SUNDI -45℃~300℃
SUNDI -45℃~300℃
SUNDI -45℃~300℃
SUNDI -45℃~300℃

SUNDI -45℃~300℃ (the system add pressure 3bar)

Temperature control of reactor and material
  • Cooling capacity0.9kW~25kW
  • Heating Power5.5kW~25kW
  • Power range9.5kW~38kW
  • Medium accuracy±0.5℃
  • Material accuracy±1℃
  • RefrigerantR404A/R507C
  • Weight245KG~420KG

Product data download

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI-555WV SUNDI-575WV SUNDI-5A10WV SUNDI-5A15WV SUNDI-5A25WV
Temp. range -45℃~+300℃  (the system add pressure 3bar)
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power 5.5 7.5 10 15 25
Cooling
capacity
kW at
250℃ 5.5 7.5 10 15 25
100℃ 5.5 7.5 10 15 25
20℃ 5.5 7.5 10 15 25
0℃ 5 7 10 15 25
-20℃ 2.9 4.2 6 11 16
-40℃ 0.9 1.5 2 3.8 4.7
Circulation pump max
L/min bar
35 50 60 110 150
1.2 1.2 1.5 1.5 2.5
Pump LNEYA magnetic drive pump
Compressor DANFOSS/ Emerson copeland vortex flexible
Expansion valve Electronic expansion valve.
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C
Connection size ZG3/4 ZG1 ZG1 ZG1 DN32 PN10
Water-cooled type
W(@20℃)
1500L/H
1.5bar~4bar
1800L/H
1.5bar~4bar
2600L/H
1.5bar~4bar
3200L/H
1.5bar~5bar
7m³/H
1.5bar~4bar
Dimension cm 55
*70
*175
55
*70
*175
65
*85
*190
65
*85
*190
80
*120
*185
Weight kg 245 285 320 360 420
Power 380V 50HZ 9kW max 11.5kW max 16kW max 23kW max 37kW max
Optional The sundi series can be selected within the heating power of 25kW. The temperature control accuracy of the medium is ±0.1°C, and the temperature control accuracy of the material is ±0.1°C.

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Displays Various Information:

1. Displays all the kind of process control temperatures.
2. Shows the liquid level of the heat conducting medium in the expansion vessel.
3. Shows indication for refrigeration system working.
4. Shows indication for heater working.
5. Shows indication for circulation pump working.
6. Displays the temp. control ( materials temp. control pattern, heat conducting medium temp. control ).
7. The temp. upper limit, lower limit control can be set.
8. The temp. difference between jacket & reactor material can be set.
9. Shows the alarm to add the liquid when it is empty.
10. The refrigeration compressor can be set to operate manuallyor automatically.

Click online message to inquire about product details
Send us a message about the product
Send us a message about the product
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/sundi-45-300.html/feed 0
SUNDI -60℃~250℃ https://www.lneya.com/special-chiller/lab-water-chiller-sundi-60-250.html https://www.lneya.com/special-chiller/lab-water-chiller-sundi-60-250.html#respond Wed, 17 May 2023 07:52:24 +0000 https://www.lneya.com/special-chiller/lab-water-chiller-sundi-60-250.html
SUNDI -60℃~250℃
SUNDI -60℃~250℃
SUNDI -60℃~250℃
SUNDI -60℃~250℃
SUNDI -60℃~250℃

SUNDI -60℃~250℃ (Water-cooled chiller&Air-cooled chiller)

rotary evaporator chiller can be cooling & heating
  • Cooling capacity0.25kW~60kW
  • Heating Power2.5kW~60kW
  • Power range5kW~95kW
  • Medium accuracy±0.5℃~±1℃
  • Material accuracy±1℃
  • RefrigerantR404A/R23
  • Weight205KG~1580KG

Product data download

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI-625
SUNDI-625W
SUNDI-635
SUNDI-635W
SUNDI-655
SUNDI-655W
SUNDI-675
SUNDI-675W
SUNDI-6A10
SUNDI-6A10W
SUNDI-6A15W SUNDI-6A25W SUNDI-6A38W SUNDI-6A60W
Temp. range  -60℃~+250℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Reaction material temp. acccuracy ±1℃
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60
Cooling capacity kW at 250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
-20℃ 2 3 4.8 6 8.2 12 25 38 56
-40℃ 0.95 1.45 2.3 3.1 4.8 7.8 18 23 31
-55℃ 0.25 0.5 0.75 0.9 1.5 2.8 6 8 11
Circulation pump max
L/min bar
20 35 35 50 60 110 150 200 250
1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5
pump Magnetic drive pump
Compressor Tecumseh closed compressor Dorin semi-closed compressor
Expansion valve Electronic expansion valve
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R23
Connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 DN32 PN10 DN40 PN10 DN50 PN10
Water-cooled type W(cooling water@20℃) 900L/H
1.5bar~4bar
1200L/H
1.5bar~4bar
1800L/H
1.5bar~4bar
2100L/H
1.5bar~4bar
3000L/H
1.5bar~4bar
4000L/H
1.5bar~4bar
8.5m³/H
1.5bar~4bar
14m³/H
1.5bar~4bar
20m³/H
1.5bar~4bar
Dimension cm 55*70*175 55*70*175 55*70*175 65*85*185 65*85*185 80*120*185 150*100*185 200*145*205 200*145*205
Weight kg 205 225 300 340 380 380 980 1350 1580
Power 380V 50HZ 5kW max 7.5kW 11kW 14kW 19kW 26.5kW 49kW 73kW 103kW

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Displays Various Information:

1. Displays all the kind of process control temperatures.
2. Shows the liquid level of the heat conducting medium in the expansion vessel.
3. Shows indication for refrigeration system working.
4. Shows indication for heater working.
5. Shows indication for circulation pump working.
6. Displays the temp. control ( materials temp. control pattern, heat conducting medium temp. control ).
7. The temp. upper limit, lower limit control can be set.
8. The temp. difference between jacket & reactor material can be set.
9. Shows the alarm to add the liquid when it is empty.
10. The refrigeration compressor can be set to operate manuallyor automatically.

Click online message to inquire about product details
Send us a message about SUNDI -60℃
Send us a message about SUNDI -60℃
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/lab-water-chiller-sundi-60-250.html/feed 0
SUNDI -70℃~250℃ https://www.lneya.com/special-chiller/laboratory-chiller-sundi-70-250.html https://www.lneya.com/special-chiller/laboratory-chiller-sundi-70-250.html#respond Wed, 17 May 2023 07:52:10 +0000 https://www.lneya.com/special-chiller/laboratory-chiller-sundi-70-250.html
SUNDI -70℃~250℃
SUNDI -70℃~250℃
SUNDI -70℃~250℃
SUNDI -70℃~250℃
SUNDI -70℃~250℃

SUNDI -70℃~250℃

Water-cooled chiller&Air-cooled chiller
  • Cooling capacity0.4kW~15kW
  • Heating Power2.5kW~15kW
  • Power range5.2kW~28kW
  • Medium accuracy±0.5℃
  • Material accuracy±1℃
  • RefrigerantR404A/R23
  • Weight190KG~420KG

Product data download

Click online message to inquire about product details
Send us a message about the product
Send us a message about the product
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI-725W SUNDI-735
SUNDI-735W
SUNDI-755
SUNDI-755W
SUNDI-775
SUNDI-775W
SUNDI-7A10W SUNDI-7A15W
Temp. range -70℃~+250℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 Or 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 2.5 3.5 5.5 7.5 10 15
Cooling capacity kW at 250℃ 2.5 3.5 5.5 7.5 10 15
100℃ 2.5 3.5 5.5 7.5 10 15
20℃ 2.5 3.5 5.5 7.5 10 15
-60℃ 0.4 0.55 0.75 0.9 1.2 2.8
Circulation pump max
L/min bar
20 35 35 50 60 110
    1.2 1.2 1.2 1.2 1.5 1.5
Pump LNEYA magnetic drive pump
Compressor Tecumseh Dorin
Expansion valve Electronic expansion valve
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R23
Connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1
Water-cooled type W(cooling water@20℃) 900L/H
1.5bar~4bar
1200L/H
1.5bar~4bar
1800L/H
1.5bar~4bar
2300L/H
1.5bar~4bar
3200L/H
1.5bar~4bar
4500L/H
1.5bar~4bar
Dimension cm 55*70*175 55*70*175 65*85*185 65*85*185 70*85*185 80*120*185
Weight kg 190 275 320 370 370 420
Power 380V 50HZ 220V 5.8kW 8kW 11kW 14kW 19kW 28kW

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Displays Various Information:

1. Displays all the kind of process control temperatures.
2. Shows the liquid level of the heat conducting medium in the expansion vessel.
3. Shows indication for refrigeration system working.
4. Shows indication for heater working.
5. Shows indication for circulation pump working.
6. Displays the temp. control ( materials temp. control pattern, heat conducting medium temp. control ).
7. The temp. upper limit, lower limit control can be set.
8. The temp. difference between jacket & reactor material can be set.
9. Shows the alarm to add the liquid when it is empty.
10. The refrigeration compressor can be set to operate manuallyor automatically.

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/laboratory-chiller-sundi-70-250.html/feed 0
SUNDI -80℃~250℃ https://www.lneya.com/special-chiller/industrial-water-chiller-system-sundi-80-250.html https://www.lneya.com/special-chiller/industrial-water-chiller-system-sundi-80-250.html#respond Wed, 17 May 2023 07:52:03 +0000 https://www.lneya.com/special-chiller/industrial-water-chiller-system-sundi-80-250.html
SUNDI -80℃~250℃
SUNDI -80℃~250℃
SUNDI -80℃~250℃
SUNDI -80℃~250℃
SUNDI -80℃~250℃

SUNDI -80℃~250℃

Heater Cooler Unit
  • Heating Power3kW~80kW
  • Cooling capacity0.3kW~80kW
  • Power range7.5kW~150kW
  • Medium accuracy±0.5℃~±1℃
  • Material accuracy±1℃
  • RefrigerantR404A/R508B
  • Weight240KG~2850KG

Product data download

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI-825W SUNDI-835W SUNDI-855W SUNDI-875W SUNDI-8A10W SUNDI-8A15W SUNDI-8A25W SUNDI-8A38W SUNDI-8A60W SUNDI-8A80W
Temp. range -80℃~+250℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 80
Cooling capacity kW at 250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
0℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
-40℃ 1.8 2.6 3.3 5.8 6.4 11 20 31 48 65
-60℃ 1 1.4 1.6 3 3.5 5.8 10 16 23 32
-75℃ 0.3 0.42 0.7 1.3 1.5 2.4 5 8 11 16
Circulation pump max
L/min bar
20 35 35 50 60 110 150 200 400 400
1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5
Pump Magnetic drive pump
Compressor Emerson Valley Wheel Vortex Flexible Compressor/Carlisle
Expansion valve Electronic expansion valve
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R23/R14
Connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 DN32 PN10 DN40 PN10 DN65 PN10 DN65 PN10
Water-cooled type W(cooling water@20℃) 1800L/H
1.5bar~4bar
2000L/H
1.5bar~4bar
2400L/H
1.5bar~4bar
3500L/H
1.5bar~4bar
3600L/H
1.5bar~4bar
5200L/H
1.5bar~4bar
10m³/H
1.5bar~4bar
18m³/H
1.5bar~4bar
28m³/H
1.5bar~4bar
30m³/H
1.5bar~4bar
Dimension cm 55*70*175 55*70*175 65*85*185 70*85*185 70*80*185 80*120*185 150*100*185 200*145*205 245*170*225 300*160*225
Weight kg 240 285 345 500 600 950 1300 1550 2200 2850
Power 380V 50HZ 7.5kW 9kW 12kW 17kW 22kW 32kW 54kW 82kW 130kW 177kW

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Click online message to inquire about product details
Send us a message about the product
Send us a message about the product
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

    loading…

    已经是到最后一篇内容了!

    ]]>
    https://www.lneya.com/special-chiller/industrial-water-chiller-system-sundi-80-250.html/feed 0
    SUNDI -90℃~250℃ https://www.lneya.com/special-chiller/temperature-control-system-sundi-90-250.html https://www.lneya.com/special-chiller/temperature-control-system-sundi-90-250.html#respond Wed, 17 May 2023 07:51:56 +0000 https://www.lneya.com/special-chiller/temperature-control-system-sundi-90-250.html
    SUNDI -90℃~250℃
    SUNDI -90℃~250℃
    SUNDI -90℃~250℃
    SUNDI -90℃~250℃
    SUNDI -90℃~250℃

    SUNDI -90℃~250℃(the system add pressure 3bar)

    Temperature control of reactor and material
    • Heating Power3kW~80kW
    • Cooling capacity0.2kW~80kW
    • Power range8kW~170kW
    • Medium accuracy±0.5℃~±1℃
    • Material accuracy±1℃
    • RefrigerantR404A/R508B
    • Weight260KG~3150KG

    Product data download

    Product Description

    ● Working temperatures from -120°C to +350°C
    ● Previously unachievable performance
    ●Intelligent temperature control
    ● Maximum process stability and reproducibility
    ● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
    ● High cooling power from 0.5 to 1200kW
    ● Large temperature range without fluid change
    ● Closed system, extend thermal fluid lifetime
    ● 7-inch, 10-inch color TFT touch screen display
    ● Comprehensive warning and safety functions
    ● Rapid cooling down from high temperature (from 300 °C)
    ● Use magnetic drive pump, solve the circulation pump leakage

    Configuration Details

    Model SUNDI-925W SUNDI-935W SUNDI-955W SUNDI-975W SUNDI-9A10W SUNDI-9A15W SUNDI-9A25W SUNDI-9A38W SUNDI-9A60W SUNDI-9A80W
    Temp. range -90℃~+250℃(the system add pressure 3bar)
    Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
    Temp. control Process temp. control and jacket temp. control model
    Temp. difference Set or control the temperature difference between jacket oil and raw material process
    Program Editor 10 programs, each program can edit 40 steps.
    Communication Portocol MODBUS RTU Protocol,RS485 interface
    Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
    Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
    Medium temp. acccuracy ±0.5℃ ±1℃
    Material temp. accuracy ±1℃
    Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 80
    Cooling capacity kW at 250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
    0℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
    -40℃ 2 2.8 5 6 8 12 20 31 48 64
    -60℃ 1.1 1.9 2.8 3.2 4.2 6 10 16 24 32
    -80℃ 0.35 0.5 0.8 1.2 1.6 2.1 3.5 6 11 15
    -85℃ 0.2 0.3 0.5 0.7 0.85 1.3 1.9 3.5 6 8
    Circulation pump max
    L/min bar
    20 35 35 50 60 110 150 200 400 400
    2 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5
    Pump LNEYA magnetic drive pump German magnetic drive pump
    Compressor Tecumseh closed compressor Dorin semi-closed compressor
    Expansion valve Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
    Evaporator DANFOSS/KAORI Plate heat exchanger
    Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
    Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
    Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
    Refrigerant R404A/R23/R14 mixture,optional: R125/R23/R14 mixture
    Connection size G3/4 G3/4 G3/4 G1 G1 DN32 PN10 DN32 PN10 DN40 PN10 DN50 PN10 DN50 PN10
    Water-cooled type W(cooling water@20℃) 1100L/H
    1.5bar~4bar
    1900L/H
    1.5bar~4bar
    2400L/H
    1.5bar~4bar
    3200L/H
    1.5bar~4bar
    4000L/H
    1.5bar~4bar
    8m³/H
    1.5bar~4bar
    12m³/H
    1.5bar~4bar
    20m³/H
    1.5bar~4bar
    30m³/H
    1.5bar~4bar
    40m³/H
    1.5bar~4bar
    Dimension cm 55*100*175 45*85*130 55*100*175 55*100*175 70*100*175 100*150*185 205*145*205 205*145*205 245*145*225 300*160*225
    Weight kg 260 295 365 570 680 950 1400 1750 2400 3150
    Power 380V 50HZ 8kW 11kW 16kW 21kW 27kW 38kW 54kW 79kW 120kW 170kW

    Working Principle

    Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

    Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

    Displays Various Information:

    1. Displays all the kind of process control temperatures.
    2. Shows the liquid level of the heat conducting medium in the expansion vessel.
    3. Shows indication for refrigeration system working.
    4. Shows indication for heater working.
    5. Shows indication for circulation pump working.
    6. Displays the temp. control ( materials temp. control pattern, heat conducting medium temp. control ).
    7. The temp. upper limit, lower limit control can be set.
    8. The temp. difference between jacket & reactor material can be set.
    9. Shows the alarm to add the liquid when it is empty.
    10. The refrigeration compressor can be set to operate manuallyor automatically.

    Click online message to inquire about product details
    Send us a message about the product
    Send us a message about the product
    *
    *
    正在提交中….
    提交成功!
    提交失败!请稍后再试
    邮箱错误!
    电话错误!

    You may also be interested in these products

    loading…

    已经是到最后一篇内容了!

    ]]>
    https://www.lneya.com/special-chiller/temperature-control-system-sundi-90-250.html/feed 0