semiconductor test chiller – LNEYA Industrial Chillers Manufacturer Supplier https://www.lneya.com Air Chiller and Water Chiller Fri, 07 Mar 2025 03:27:29 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.2 https://www.lneya.com/wp-content/uploads/2024/05/logo-lneya-150x150.jpg semiconductor test chiller – LNEYA Industrial Chillers Manufacturer Supplier https://www.lneya.com 32 32 Semiconductor diffusion furnace configuration temperature control equipment https://www.lneya.com/news/industry-news/semiconductor-diffusion-furnace-temperature-control-chiller.html https://www.lneya.com/news/industry-news/semiconductor-diffusion-furnace-temperature-control-chiller.html#respond Wed, 10 Apr 2024 03:14:41 +0000 https://www.lneya.com/?p=7805 Semiconductor diffusion furnace configuration temperature control equipment

Gas phase diffusion requires precise control of the concentration, temperature, and time of the diffusion gas to ensure the accuracy and uniformity of doping. Diffusion furnaces are usually equipped with temperature control systems, gas flow control systems, and diffusion control systems to achieve precise control of the diffusion process.

The diffusion furnace equipment usually consists of four main parts: heating chamber, atmosphere control system, temperature control system, and control system. Temperature control system: The temperature control system is used to precisely control the temperature of the heating chamber. Usually, methods such as thermocouples or radiation heaters are used to measure and regulate temperature. Control system: Diffusion furnace equipment is usually equipped with a control system to automatically control various parameters of the diffusion process, such as temperature, time, flow rate, etc. The control system can choose a human-machine interface, making operation more convenient and intuitive.

Diffusion furnaces are widely used in semiconductor processes, including the manufacturing of transistors, diodes, and solar cells. In addition, diffusion furnaces are also applied in fields such as glass industry and ceramic industry.

loading…

已经是到最后一篇内容了!

REQUEST A QUOTE

Submit your product intentions and requirements.

*
*
Submiting
successfully!
error!
error!
error!
]]>
https://www.lneya.com/news/industry-news/semiconductor-diffusion-furnace-temperature-control-chiller.html/feed 0
Precautions for using the wafer testing temperature control system https://www.lneya.com/news/industry-news/precautions-for-using-the-wafer-testing-temperature-control-system.html https://www.lneya.com/news/industry-news/precautions-for-using-the-wafer-testing-temperature-control-system.html#respond Tue, 19 Mar 2024 02:47:04 +0000 https://www.lneya.com/?p=7348 Precautions for using the wafer testing temperature control system

The wafer testing temperature control system can provide high and low temperature environments for experimental use. However, as an instrument, its operation also needs to follow certain precautions. This article will introduce in detail the operating precautions of the wafer testing temperature control system to ensure the accuracy and safety of the experiment.

The wafer testing temperature control system mainly consists of a refrigeration system, a heating system, a control system and a temperature sensor. It can achieve accurate control of high and low temperature environments by adjusting the parameters of the heating system and refrigeration system.

loading…

已经是到最后一篇内容了!

Before using the wafer to test the temperature control system, we need to conduct a series of checks. Check whether the power connection of the device is normal and whether the power plug is tight. Secondly, check whether the pipeline connections of the equipment are tight and whether there are leaks. In addition, the internal cleanliness of the equipment should be checked to ensure the accuracy of the experimental results.

When operating the wafer testing temperature control system, we need to pay attention to the following tips. Avoid moving or tilting the equipment while it is in operation to avoid unnecessary injury. Secondly, make sure that the experimental samples are placed securely and do not place them on the edge or sliding parts of the equipment to avoid falling and damaging the equipment or causing personal injury.

When setting the temperature, adjust the temperature step by step and always pay attention to the difference between the device’s display temperature and the set temperature. If the difference is too large, the parameters of the heating system and refrigeration system should be adjusted in time. At the same time, it is necessary to keep the equipment clean and clean the condenser, evaporator and other components regularly to ensure the heat dissipation and cooling effect of the equipment.

Long-term use of the wafer test temperature control system may result in equipment performance degradation or failure. Therefore, we must regularly inspect and maintain the equipment to detect and solve problems in a timely manner. At the same time, the filter, oil and other accessories of the equipment should be replaced regularly according to the equipment instructions to ensure the normal operation of the equipment.

In short, the operation of the wafer testing temperature control system requires attention to many aspects. During use, we must strictly abide by the operating procedures of the equipment and always pay attention to the operating status of the equipment and changes in experimental results. At the same time, you also need to pay attention to tips and equipment maintenance precautions to ensure the accuracy and safety of the experiment.

Submit for consultation

*
*
正在提交!
提交成功!
提交失败!
邮箱错误!
电话错误!

]]>
https://www.lneya.com/news/industry-news/precautions-for-using-the-wafer-testing-temperature-control-system.html/feed 0
Wafer thin film deposition temperature control equipment chiller usage environment https://www.lneya.com/news/industry-news/wafer-thin-film-deposition-temperature-control-equipment-chiller-usage-environment.html https://www.lneya.com/news/industry-news/wafer-thin-film-deposition-temperature-control-equipment-chiller-usage-environment.html#respond Tue, 19 Mar 2024 02:47:04 +0000 https://www.lneya.com/?p=7360 Wafer thin film deposition temperature control equipment chiller usage environment

The wafer thin film deposition temperature control equipment chiller is an equipment used for cooling and heating temperature control testing in the component semiconductor manufacturing industry. So what should you pay attention to when using the environment?

1.Power distribution requirements for chiller unit of wafer thin film deposition temperature control equipment:

  • Main power supply voltage: Within the rated voltage requirements, when the main power supply voltage fluctuation exceeds the specified range, the component high and low temperature testing machine chiller is not allowed to be started, otherwise it will be regarded as improper operation, and the damage caused thereby is not within the scope of our company’s maintenance. The water flow switch, water pump, cooling tower motor and other interlocking circuits of the water system can be correctly connected to the unit control circuit when necessary.
  • The chiller unit of the wafer thin film deposition temperature control equipment is equipped with various measures and control circuits such as current overload protection, high and low pressure protection at the compressor exhaust end, motor coil overheating protection, anti-icing protection, cooling water flow chain protection, etc. The control circuit of the chiller group of LNEYA’s wafer thin film deposition temperature control equipment has been installed and debugged in the factory. Do not make any unauthorized changes. If you need to make any changes, please contact the technical department.

2.The following matters should be noted during installation:

  • When lifting and installing the wafer thin film deposition temperature control equipment chiller, be careful not to damage the unit, and arrange the surrounding space reasonably to facilitate the maintenance of the wafer thin film deposition temperature control equipment chiller.

  • According to the requirements for piping system design and construction and installation, the frozen water and cooling water system should be reasonably designed and installed to give full play to the chiller performance of the wafer thin film deposition temperature control equipment. It should be placed horizontally and installed in a ventilated position. For unit piping, please refer to the LNEYA product manual for recommended installation and construction.

When the environment around the water source and radiator tower is harsh, the chilled water and cooling water circuits must be installed with Y-type filters and cleaned regularly. An automatic exhaust valve must be installed at the top of the closed chilled water system, and a

Submit for consultation

*
*
正在提交!
提交成功!
提交失败!
邮箱错误!
电话错误!
]]>
https://www.lneya.com/news/industry-news/wafer-thin-film-deposition-temperature-control-equipment-chiller-usage-environment.html/feed 0
How to purchase a power management chip temperature test system? https://www.lneya.com/news/industry-news/how-to-purchase-a-power-management-chip-temperature-test-system.html https://www.lneya.com/news/industry-news/how-to-purchase-a-power-management-chip-temperature-test-system.html#respond Tue, 19 Mar 2024 02:47:04 +0000 https://www.lneya.com/?p=7367 How to purchase a power management chip temperature test system?

The power management chip temperature test system is an important equipment used to test the performance and reliability of semiconductor chips in different temperature environments. When purchasing this type of test equipment, you need to consider the following points:

  • Temperature range: According to the test requirements, determine the temperature range required for testing. The power management chip temperature test system should be able to provide stable temperature control within a certain range to ensure the accuracy and repeatability of test results.
  • Test sample size: Consider the size and shape of the semiconductor chip to be tested to ensure that the test sample can be installed correctly into the testing machine and will not be affected by mechanical stress or overheating.
  • Temperature stability: The temperature stability of the power management chip temperature test system has a great impact on its test results. A testing machine that can maintain a stable temperature within the required temperature range should be selected to ensure the reliability of the test results.
  • Heating and cooling speed: Heating and cooling speed will affect test efficiency, especially for tests that require rapid temperature changes. Choosing a testing machine with rapid heating and cooling capabilities can shorten testing time and improve work efficiency.
  • Temperature uniformity: The temperature at various locations inside the testing machine should be as uniform as possible to ensure that all test samples are tested under the same temperature conditions. This will help obtain accurate test results and avoid poor repeatability of test results due to uneven temperatures.
  • Control system: Choose the power management chip temperature test system of Guanya Refrigeration Control System to ensure accurate temperature control and real-time monitoring of temperature changes. In addition, an easy-to-operate user interface is also one of the factors that need to be considered when purchasing, so that operators can quickly get started and perform tests.
  • Reliability: The power management chip temperature test system should have high reliability and stability, be able to work continuously for a long time and maintain accurate temperature control. When purchasing, you should consider choosing a brand and equipment that has undergone strict quality control to ensure its performance and reliability.
  • After-sales service: Choose a supplier that provides comprehensive after-sales service to ensure that you can receive timely solutions and technical support when encountering problems during use. In addition, suppliers should provide equipment maintenance and regular calibration services to ensure the accuracy and reliability of the equipment.
  • Cost-effectiveness: When purchasing a power management chip temperature test system, cost-effectiveness needs to be considered. Choose equipment that fits your budget while ensuring it meets your testing needs and offers high performance and reliability.

In short, when purchasing a power management chip temperature test system, you need to consider the above points comprehensively to ensure that the purchased equipment can meet the testing needs and has high performance and reliability. At the same time, it is also very important to choose a supplier that provides after-sales service.

Submit for consultation

*
*
正在提交!
提交成功!
提交失败!
邮箱错误!
电话错误!

]]>
https://www.lneya.com/news/industry-news/how-to-purchase-a-power-management-chip-temperature-test-system.html/feed 0
LTS -20℃~80℃ https://www.lneya.com/component-test-temp-control-systems/lts-20-80.html https://www.lneya.com/component-test-temp-control-systems/lts-20-80.html#comments Wed, 17 May 2023 07:57:33 +0000 https://www.lneya.com/special-chiller/lts-20-80.html
LTS -20℃~80℃

LTS -20℃~80℃ Fluoride cooling and heating system

Temperature control during semiconductor manufacturing
  • Flow control12L/min~45L/min
  • Internal circulating liquid4L~10L
  • Expansion tank10L~20L
  • Place of OriginChina

Product data download

Parameters Detailed

ModelLTS-202LTS-203LTS-204LTS-206LTS-208
LTS-202WLTS-203WLTS-204WLTS-206WLTS-208W
Temperature range -20℃~35℃
Temperature control accuracy±0.1℃  at  -20℃~0℃
Flow control 7~25L/min12~45L/min
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume4L5L6L8L10L
Expansion tank volume10L10L15L15L20L
System pressure displayThe pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
ControllerSPLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature controlHeat transfer medium outlet temperature control mode
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreementEthernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipmentEquipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation systemThe whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
CompressorEmerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pumpMagnetic circulation pump
EvaporatorPlate heat exchanger
CondenserMicro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessoriesDanfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panelLNEYA customized 7-inch color touch screen, temperature curve display\EXCEL data export
SecurityWith self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface sizeZG1/2ZG1/2ZG3/4ZG3/4ZG3/4

Product Description

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Click online message to inquire about product details
Send us a message about LTS series
Send us a message about LTS series
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/component-test-temp-control-systems/lts-20-80.html/feed 1
LTS -40℃~80℃ https://www.lneya.com/component-test-temp-control-systems/lts-40-80.html https://www.lneya.com/component-test-temp-control-systems/lts-40-80.html#respond Wed, 17 May 2023 07:57:28 +0000 https://www.lneya.com/special-chiller/lts-40-80.html
LTS -40℃~80℃

LTS -40℃~35℃

Temperature control during semiconductor manufacturing
  • Flow control12L/min~45L/min
  • Temperature accuracy±0.1℃ @40℃~-10℃
  • Internal circulating liquid4L~10L
  • Expansion tank10L~20L
  • Place of OriginChina

Product data download

Parameters Detailed

Model
LTS-402
LTS-403
LTS-404
LTS-406
LTS-408
LTS-402W
LTS-403W
LTS-404W
LTS-406W
LTS-408W
Temperature range
  -40℃~35℃
Temperature control accuracy
±0.1℃  -40℃~-10℃
Flow control 
7~25L/min
12~45L/min
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume
4L
5L
6L
8L
10L
Expansion tank volume
10L
10L
15L
15L
20L
System pressure display
The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controller
PLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature control
Heat transfer medium outlet temperature control mode
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreement
Ethernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipment
Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation system
The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressor
Emerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pump
Magnetic circulation pump
Evaporator
Plate heat exchanger
Condenser
Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessories
Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panel
Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security
With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface size
ZG1/2
ZG1/2
ZG3/4
ZG3/4
ZG3/4

 

Product Description

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Click online message to inquire about product details
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/component-test-temp-control-systems/lts-40-80.html/feed 0
LTS -60℃~80℃ https://www.lneya.com/component-test-temp-control-systems/lts-60-80.html https://www.lneya.com/component-test-temp-control-systems/lts-60-80.html#respond Wed, 17 May 2023 07:57:23 +0000 https://www.lneya.com/special-chiller/lts-60-80.html
LTS -60℃~80℃

LTS -60℃~80℃ Fluoride cooling heating system

Temperature control during semiconductor manufacturing
  • Flow control12L/min~45L/min
  • Temperature accuracy±0.1℃ @-60℃~-30℃
  • Internal circulating liquid4L~10L
  • Expansion tank10L~20L
  • Place of OriginChina

Product data download

Parameters Detailed

Model LTS-602 LTS-603 LTS-604 LTS-606 LTS-608
LTS-602W LTS-603W LTS-604W LTS-606W LTS-608W
Temperature range   -60℃~-20℃
Temperature control accuracy ±0.1℃  -60℃~-30℃
Flow control  7~25L/min 12~45L/min
  The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume 4L 5L 6L 8L 10L
Expansion tank volume 10L 10L 15L 15L 20L
System pressure display The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controller PLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature control Heat transfer medium outlet temperature control mode
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreement Ethernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipment Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation system The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressor Emerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pump Magnetic circulation pump
Evaporator Plate heat exchanger
Condenser Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessories Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panel Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface size ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4

Product Description

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Click online message to inquire about product details
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/component-test-temp-control-systems/lts-60-80.html/feed 0
LTS -80℃~80℃ https://www.lneya.com/component-test-temp-control-systems/lts-80-80.html https://www.lneya.com/component-test-temp-control-systems/lts-80-80.html#respond Wed, 17 May 2023 07:57:19 +0000 https://www.lneya.com/special-chiller/lts-80-80.html
LTS -80℃~80℃

LTS -80℃~80℃ Fluoride cooling heating system

Temperature control during semiconductor manufacturing
  • Flow control12L/min~45L/min
  • Temperature accuracy±0.1℃ @-60℃~-30℃
  • Internal circulating liquid4L~10L
  • Expansion tank10L~20L
  • Place of OriginChina

Product data download

Product Parameters

Model LTS-802 LTS-803 LTS-804 LTS-806 LTS-808
  LTS-802W LTS-803W LTS-804W LTS-806W LTS-808W
Temperature range   -80℃~-20℃
Temperature control accuracy ±0.1℃  -80℃~-50℃
Flow control  7~25L/min 12~45L/min
  The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume 4L 5L 6L 8L 10L
Expansion tank volume 10L 10L 15L 15L 20L
System pressure display The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
  The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controller Siemens PLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature control Heat transfer medium outlet temperature control mode
  External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreement Ethernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipment Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation system The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressor Emerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pump German brand magnetic circulation pump
Evaporator Adopt Danfoss/Gaoli plate heat exchanger
Condenser Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessories Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panel Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface size G1/2 G1/2 G3/4 G3/4 G3/4

Product Description

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Click online message to inquire about product details
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/component-test-temp-control-systems/lts-80-80.html/feed 0
TES -45℃~250℃ https://www.lneya.com/component-test-temp-control-systems/semiconductor-cooling-heating/chip-test-dedicated-tes-equipment.html https://www.lneya.com/component-test-temp-control-systems/semiconductor-cooling-heating/chip-test-dedicated-tes-equipment.html#respond Wed, 17 May 2023 07:56:00 +0000 https://www.lneya.com/special-chiller/chip-test-dedicated-tes-equipment.html
TES -45℃~250℃
TES -45℃~250℃
TES -45℃~250℃
TES -45℃~250℃
TES -45℃~250℃

TES -45℃~250℃

cooling heating system temperature control for Semiconductor test
  • Heating Power3kW~25kW
  • Cooling capacity0.3kW~25kW
  • Power range6kW~36kW
  • Medium accuracy±0.3℃
  • Flow pressure25L/min~150L/min 2.5bar
  • RefrigerantR404A/R507C

Product data download

Parameters

Temperature control range:-45°C ~ 250°C ;Power range:2.5kW~25kW;Temperature control accuracy:±0.3°C


Chip-Specific High and Low Temperature Test Boxes In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing at temperatures (-85 °C to +200 °C) and other environments. Test the simulation. Once put into practical use, these semiconductor devices and electronic products can be exposed to extreme environmental conditions to meet demanding military and telecommunications reliability standards.

  LNEYA represents the international advanced liquid temperature control technology, actively explores and studies component testing systems, mainly used for temperature test simulation in semiconductor testing, with wide temperature orientation and high temperature rise and fall, temperature range -92°C ~ 250°C, suitable for various Test Requirements. LNEYA is committed to solving the problem of temperature control lag in electronic components. Ultra high temperature cooling technology can be cooled directly from 300°C.

Model TES-4525 TES-4555 TES-45A10 TES-45A15 TES-45A25
TES-4525W TES-4555W TES-45A10W TES-45A25W TES-45A25W
Temp. Range   -45℃~250℃ -45℃~250℃ -45℃~250℃ -45℃~250℃ -45℃~250℃
Heating Power 3kW 5.5kW 10kW 15kW 25kW
Refrigerating output 250℃ 3kW 5.5kW 10kW 15kW 25kW
100℃ 2.5kW 5.5kW 10kW 15kW 25kW
20℃ 2.5kW 5.5kW 10kW 15kW 25kW
0℃ 2.5kW 5kW 10kW 15kW 25kW
-20℃ 1kW 2.9kW 6kW 11kW 16kW
-40℃ 0.3kW 0.9kW 2kW 3.8kW 5.3kW
Temp. control accuracy of heat conduction medium ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
System pressure display The pressure of the refrigeration system is realized by the pointer type pressure gauge (high-pressure and low-pressure).
The circulation system pressure is displayed on the touch screen by pressure sensor detection.
controller Siemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm
Temp. control Temperature Control Mode for outlet of Heat conduction medium;
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control)
Programmable5  procedures can be developed, and each program can be composed of 40 steps
Communicating protocol Ethernet Interface TCP/IP Protocol
Internal temp. feedback of equipment Equipment heat-conducting medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (configuration of water-cooling equipment)
External access temp. feedback PT100 or 4~20mA or communication given
String-level control The temperature difference between the outlet temperature and the external temperature sensor can be set and controlled;
Temp. difference control function The temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system).
Closed-cycle system The whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature.
Heating Power The maximum heating output power of the system (according to each model);
The heater has triple protection and independent temperature limiter to ensure the safety of heating system;
The power is more than 10kW and the voltage regulator is adopted, and the heating power output control is controlled by 4-20mA linear control.
Cooling capacity It refers to the ability to carry away heat at different temperatures (in the ideal state). The actual working conditions need to be considered for environmental heat dissipation. Please enlarge it properly and do well the thermal insulation measures.
Circulation pump flow, pressure max Adopt LNEYA magnetic drive pump
25L/min2.5bar 50L/min2.5bar 50L/min2.5bar 110L/min2.5bar 150L/min2.5bar
Compression engine Tekokang,France Emerson Emerson / Danvers Emerson / Danvers Emerson / Danvers
Evaporimeter With DANFOSS/High pressure Plate Heat Exchanger
Refrigeration Accessory Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves)
Operation panel LNEYA custom 7-inch color touch screen, temperature curve display\ EXCEL data export
Safe guarding With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
Cryogen R-404A / R507C
Interface size ZG1/2 ZG3/4 ZG3/4 ZG1 DN32 PN10 RF
Shape size (Air-cooled type)cm 45*70*160 55*70*175 65*85*185 80*120*185 100*150*185
Air-cooled type It adopts copper tube aluminum fin condensation method, upper air outlet type, and the condensation fan adopts German EBM axial flow fan.
Water-cooled type W Type W is water cooled
Water-cooled Condenser Casing heat exchanger (Paris / Shen’s)
Cooling water quantity at 25℃ 1.1m3/h 1.5m3/h 2.6m3/h 3.6m3/h 7m3/h
Source 380V50HZ 6kW max 220V 9kW max 16kW max 23kW max 36kW max
Source Customizable 460V 60HZN 220V 60HZ three-phase
Shell material Cold rolled sheet spray (Standard Colour 7035)
Isolation explosion proof Customizable isolation explosion proof (EXdIIBT4);
Installation License No. of Wuxi Guanzi Explosion-proof Product: PCEC-2017-B025
Barotropic explosion protection A custom positive pressure explosion-proof (EXPXdmbIICT4) positive pressure system must be a water-cooled device;
Installation License No. of Wuxi Guanzi Explosion-proof Product: PCEC-2017-B025

Product Description

TES
Temperature control range:-45°C ~ 250°C ;Power range:2.5kW~25kW;Temperature control accuracy:±0.3°C
Chip-Specific High and Low Temperature Test Boxes In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing at temperatures (-85 °C to +200 °C) and other environments. Test the simulation. Once put into practical use, these semiconductor devices and electronic products can be exposed to extreme environmental conditions to meet demanding military and telecommunications reliability standards.


Click online message to inquire about product details
Send us a message about TES series
Send us a message about TES series
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/component-test-temp-control-systems/semiconductor-cooling-heating/chip-test-dedicated-tes-equipment.html/feed 0
TES -85℃~200℃ https://www.lneya.com/component-test-temp-control-systems/semiconductor-cooling-heating/chip-test-dedicated-tes-85-equipment.html https://www.lneya.com/component-test-temp-control-systems/semiconductor-cooling-heating/chip-test-dedicated-tes-85-equipment.html#respond Wed, 17 May 2023 07:55:56 +0000 https://www.lneya.com/special-chiller/chip-test-dedicated-tes-85-equipment.html
TES  -85℃~200℃
TES  -85℃~200℃
TES  -85℃~200℃
TES  -85℃~200℃
TES  -85℃~200℃

TES -85℃~200℃

cooling heating system temperature control Semiconductor test chiller
  • Heating Power2.5kW~25kW
  • Cooling capacity0.25kW~25kW
  • Power range6.5kW~50kW
  • Medium accuracy±0.3℃
  • Flow pressure20L/min~150L/min 2.5bar
  • RefrigerantR404A/R508B

Product data download

Temperature control range:-85°C ~ 200°C ;Power range:6.5kW~50kW;Temperature control accuracy:±0.3°C


Chip-Specific High and Low Temperature Test Boxes In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing at temperatures (-85 °C to +200 °C) and other environments. Test the simulation. Once put into practical use, these semiconductor devices and electronic products can be exposed to extreme environmental conditions to meet demanding military and telecommunications reliability standards.

  LNEYA represents the international advanced liquid temperature control technology, actively explores and studies component testing systems, mainly used for temperature test simulation in semiconductor testing, with wide temperature orientation and high temperature rise and fall, temperature range -92°C ~ 250°C, suitable for various Test Requirements. LNEYA is committed to solving the problem of temperature control lag in electronic components. Ultra high temperature cooling technology can be cooled directly from 300°C.

Parameters

Model TES-8525W TES-8555W TES-85A10W TES-85A15W TES-85A25W
Temp. Range  -85℃~200℃ -85℃~200℃ -85℃~200℃ -85℃~200℃ -85℃~200℃
Heating Power 2.5kW 5.5kW 10kW 15kW 25kW
Refrigerating Output 200℃ 2.5kW 5.5kW 10kW 15kW 25kW
100℃ 2.5kW 5.5kW 10kW 15kW 25kW
20℃ 2.5kW 5.5kW 10kW 15kW 25kW
0℃ 2.5kW 5.5kW 10kW 15kW 25kW
-40℃ 1.5kW 3.3kW 6.5kW 11kW 20kW
-60℃ 0.85kW 1.8kW 3.4kW 6.5kW 10kW
-80℃ 0.25kW 0.45kW 1.5kW 2.5kW 4kW
Temp. Control Accuracy of Heat Conduction Medium ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
System Pressure Display Pressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure);
Pressure of circulatory system is detected by pressure sensor and displayed on touch screen.
Controller Siemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm.
Temp. Control Temperature Control Mode for outlet of Heat conduction medium;
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control)
Programmable 5 procedures can be developed, and each program can be composed of 40 steps
Communicating Protocol Ethernet Interface TCP/IP Protocol
Internal Temperature Feedback Outlet temperature, inlet temperature, condensing temperature, ambient temperature, suction temperature of compressor, cooling water temperature (water cooling equipment configuration) of equipment heat conduction medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature.
External Access Temp Feedback PT100 or 4~20mA or communication given.
Cascade control time The temperature difference between the outlet temperature and the external temperature sensor can be set and controlled;
Temp. difference control function The temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system).
Closed-cycle system The whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature.
Heating Power The maximum heating output power of the system (According to each model);
The heater has triple protection and independent temperature limiter to ensure the safety of heating system;
The power is more than 10kW and the voltage regulator is adopted, and the heating power output control is controlled by 4-20mA linear control.
Refrigerating Capacity Refers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures.
Circulating pump flow (max) Magnetic drive pump
20L/min2.5bar 50L/min2.5bar 50L/min2.5bar 110L/min2.5bar 150L/min2.5bar
Compression Engine Tecumseh Emerson Scroll flexible compressor
Evaporimeter Plate heat exchanger
Refrigeration Accessory Danfoss / Emerson accessories (dry filters, oil separators, high and low pressure protectors, mirrors)
Expansion Valve Danfoss thermal expansion valve+Emerson electronic expansion valve
Operation Panel LNEYA custom 7-inch color touch screen, temperature curve display\ EXCEL data export
Safe Guarding With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
Cryogen R404A R508B
Interface size ZG1/2 ZG3/4 ZG3/4 ZG1 DN32 PN10 RF
External dimension (water cooling) 55*70*175 65*85*185 80*120*185 100*150*185 200*145*205
Water-cooled W Type W is water cooled
Water-cooled Condenser Casing heat exchanger (Paris / Shen’s)
Cooling Water At 20 ℃ 2000L/H 2400L/H 3500L/H 5200L/H 12m³/H
1.5bar~4bar 1.5bar~4bar 1.5bar~4bar 1.5bar~4bar 1.5bar~4bar
Power 380V50HZ 7.5kW max 13kW max 22kW max 32kW max 54kW max
Optional AC 380V 50HZ Three-phase five-wire system
Customizable 460V 60HZ、220V 60HZ Three-phase
Shell Material Cold rolled sheet spray (Standard Colour 7035)
Isolation Explosion Proof Customizable isolation explosion-proof(EXdIIBT4)
LNEYA Explosive proof product installation license number:PCEC-2017-B025
Barotropic Explosion Protection Customizable barotropic explosion-proof (EXPXdmbIICT4) barotropic systems must be water-cooled equipment;
LNEYA Explosive product installation license number: PCEC-2017-B025

Product Description


Temperature control range:-85°C ~ 200°C ;Power range:2.5kW~25kW;Temperature control accuracy:±0.3°C

Chip-Specific High and Low Temperature Test Boxes In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing at temperatures (-85°C to +200°C) and other environments. Test the simulation. Once put into practical use, these semiconductor devices and electronic products can be exposed to extreme environmental conditions to meet demanding military and telecommunications reliability standards.

TES


Click online message to inquire about product details
Send us a message about TES series
Send us a message about TES series
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/component-test-temp-control-systems/semiconductor-cooling-heating/chip-test-dedicated-tes-85-equipment.html/feed 0