LTS series – Industrial Chillers Manufacturer Supplier – LNEYA https://www.lneya.com Air Cooling Chiller and Water Cooling Chiller Type Fri, 23 Feb 2024 02:15:06 +0000 en-US hourly 1 https://wordpress.org/?v=6.4.3 https://www.lneya.com/wp-content/uploads/2023/05/Lneya-logo-e1683777581854-150x137.png LTS series – Industrial Chillers Manufacturer Supplier – LNEYA https://www.lneya.com 32 32 LTS -20℃~80℃ https://www.lneya.com/special-chiller/lts-20-80.html https://www.lneya.com/special-chiller/lts-20-80.html#respond Wed, 17 May 2023 07:57:33 +0000 https://www.lneya.com/special-chiller/lts-20-80.html
LTS -20℃~80℃

LTS -20℃~80℃ Fluoride cooling and heating system

Temperature control during semiconductor manufacturing
  • Flow control12L/min~45L/min
  • Internal circulating liquid4L~10L
  • Expansion tank10L~20L
  • Place of OriginChina

Product data download

Parameters Detailed

ModelLTS-202LTS-203LTS-204LTS-206LTS-208
LTS-202WLTS-203WLTS-204WLTS-206WLTS-208W
Temperature range -20℃~35℃
Temperature control accuracy±0.1℃  at  -20℃~0℃
Flow control 7~25L/min12~45L/min
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume4L5L6L8L10L
Expansion tank volume10L10L15L15L20L
System pressure displayThe pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
ControllerSPLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature controlHeat transfer medium outlet temperature control mode
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreementEthernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipmentEquipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation systemThe whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
CompressorEmerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pumpMagnetic circulation pump
EvaporatorPlate heat exchanger
CondenserMicro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessoriesDanfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panelLNEYA customized 7-inch color touch screen, temperature curve display\EXCEL data export
SecurityWith self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface sizeZG1/2ZG1/2ZG3/4ZG3/4ZG3/4

Product Description

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Click online message to inquire about product details
Send us a message about LTS series
Send us a message about LTS series
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/lts-20-80.html/feed 0
LTS -40℃~80℃ https://www.lneya.com/special-chiller/lts-40-80.html https://www.lneya.com/special-chiller/lts-40-80.html#respond Wed, 17 May 2023 07:57:28 +0000 https://www.lneya.com/special-chiller/lts-40-80.html
LTS -40℃~80℃

LTS -40℃~35℃

Temperature control during semiconductor manufacturing
  • Flow control12L/min~45L/min
  • Temperature accuracy±0.1℃ @40℃~-10℃
  • Internal circulating liquid4L~10L
  • Expansion tank10L~20L
  • Place of OriginChina

Product data download

Parameters Detailed

Model
LTS-402
LTS-403
LTS-404
LTS-406
LTS-408
LTS-402W
LTS-403W
LTS-404W
LTS-406W
LTS-408W
Temperature range
  -40℃~35℃
Temperature control accuracy
±0.1℃  -40℃~-10℃
Flow control 
7~25L/min
12~45L/min
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume
4L
5L
6L
8L
10L
Expansion tank volume
10L
10L
15L
15L
20L
System pressure display
The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controller
PLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature control
Heat transfer medium outlet temperature control mode
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreement
Ethernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipment
Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation system
The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressor
Emerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pump
Magnetic circulation pump
Evaporator
Plate heat exchanger
Condenser
Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessories
Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panel
Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security
With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface size
ZG1/2
ZG1/2
ZG3/4
ZG3/4
ZG3/4

 

Product Description

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Click online message to inquire about product details
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/lts-40-80.html/feed 0
LTS -60℃~80℃ https://www.lneya.com/special-chiller/lts-60-80.html https://www.lneya.com/special-chiller/lts-60-80.html#respond Wed, 17 May 2023 07:57:23 +0000 https://www.lneya.com/special-chiller/lts-60-80.html
LTS -60℃~80℃

LTS -60℃~80℃ Fluoride cooling heating system

Temperature control during semiconductor manufacturing
  • Flow control12L/min~45L/min
  • Temperature accuracy±0.1℃ @-60℃~-30℃
  • Internal circulating liquid4L~10L
  • Expansion tank10L~20L
  • Place of OriginChina

Product data download

Parameters Detailed

Model LTS-602 LTS-603 LTS-604 LTS-606 LTS-608
LTS-602W LTS-603W LTS-604W LTS-606W LTS-608W
Temperature range   -60℃~-20℃
Temperature control accuracy ±0.1℃  -60℃~-30℃
Flow control  7~25L/min 12~45L/min
  The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume 4L 5L 6L 8L 10L
Expansion tank volume 10L 10L 15L 15L 20L
System pressure display The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controller PLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature control Heat transfer medium outlet temperature control mode
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreement Ethernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipment Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation system The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressor Emerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pump Magnetic circulation pump
Evaporator Plate heat exchanger
Condenser Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessories Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panel Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface size ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4

Product Description

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Click online message to inquire about product details
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/lts-60-80.html/feed 0
LTS -80℃~80℃ https://www.lneya.com/special-chiller/lts-80-80.html https://www.lneya.com/special-chiller/lts-80-80.html#respond Wed, 17 May 2023 07:57:19 +0000 https://www.lneya.com/special-chiller/lts-80-80.html
LTS -80℃~80℃

LTS -80℃~80℃ Fluoride cooling heating system

Temperature control during semiconductor manufacturing
  • Flow control12L/min~45L/min
  • Temperature accuracy±0.1℃ @-60℃~-30℃
  • Internal circulating liquid4L~10L
  • Expansion tank10L~20L
  • Place of OriginChina

Product data download

Product Parameters

Model LTS-802 LTS-803 LTS-804 LTS-806 LTS-808
  LTS-802W LTS-803W LTS-804W LTS-806W LTS-808W
Temperature range   -80℃~-20℃
Temperature control accuracy ±0.1℃  -80℃~-50℃
Flow control  7~25L/min 12~45L/min
  The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume 4L 5L 6L 8L 10L
Expansion tank volume 10L 10L 15L 15L 20L
System pressure display The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
  The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controller Siemens PLC, fuzzy PID control algorithm, with cascade control algorithm
Temperature control Heat transfer medium outlet temperature control mode
  External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Letter of agreement Ethernet interface TCP/IP protocol
RS485 interface modbus RTU protocol
Internal temperature feedback of equipment Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Closed circulation system The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressor Emerson Copeland/Danfoss Scroll Flexible Compressor
Circulating pump German brand magnetic circulation pump
Evaporator Adopt Danfoss/Gaoli plate heat exchanger
Condenser Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Refrigeration accessories Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Operation panel Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Security With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
In and out interface size G1/2 G1/2 G3/4 G3/4 G3/4

Product Description

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
3. Optimize temperature sampling and response speed, specially design control algorithm, can respond quickly to stable temperature control.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Click online message to inquire about product details
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

]]>
https://www.lneya.com/special-chiller/lts-80-80.html/feed 0