Analisi delle parti del refrigeratore a bassa temperatura
Il refrigeratore a bassa temperatura is a cooling water equipment which is widely used. So, when using it, you should first understand the principle of the cryogenic water chiller and its accessories, so as to run the cryogenic water chiller more efficiently.
Il refrigeratore a bassa temperatura is a kind of water-cooled cooling equipment, which can provide certain constant temperature, constant current and constant pressure refrigeration equipment. It uses the water tank in the machine to inject appropriate amount of water, cooling water through the refrigeration system, and then pumps the cooling water into the equipment that needs to be cooled. The chilled water takes the heat away from the temperature rising water and reaches the water tank to achieve a cooling effect.
Generally speaking, the refrigeratore a bassa temperatura is a relatively economical equipment. Generally, refrigerant circulating system, electrical control system and water circulating system complement each other. It is composed of condenser, compressor, thermal expansion valve, evaporator, liquid storage, drying filter, refrigerant and so on.
In the use of the refrigeratore a bassa temperatura, the condenser can play a role of heat output. Once the high-pressure gas discharged from compressor operation enters the condenser, it can absorb its heat, and can also transfer other heat in the pipeline to the surrounding media.
Compressor is very important in the refrigeratore a bassa temperatura, which belongs to the core part. It can convert electrical energy into mechanical energy. Compression refrigerant is closely related to the operation of other parts.
In the refrigeratore a bassa temperatura, the thermal expansion valve regulates the flow rate and is also a throttle valve in refrigeration equipment. It can make the liquid refrigerant of high pressure and normal temperature reduce pressure through the throttle of the thermal expansion valve, and turn into low temperature and low pressure steam to enter the evaporator to gasify and absorb heat, so as to achieve the purpose of cooling.
Of course, the evaporator is also a heat exchanger which uses refrigerant evaporation to achieve the absorption of heat by the refrigeratore a bassa temperatura. In addition, in a relatively small refrigeratore a bassa temperatura, drying filters are also necessary to prevent some other substances from entering the refrigeration system!
So, before you use the refrigeratore a bassa temperatura, you should have a good look at it. After all, there are many knowledge points. You can see more about it.
Raccomandazioni correlate
-
You Should Know Something About Ultra Low Temperature Freezer
797Ultra low temperature freezer is an indispensable cryogenic storage equipment in the field of life sciences and biopharmaceuticals. It can be used to store cells, tissues, test samples, vaccines, active enzymes, strains, plasmids, viruses, bacteri...
Visualizza i dettagli -
A cosa bisogna prestare attenzione quando si installa un sistema di raffreddamento della pila di ricarica CC?
919prestare attenzione quando si installa un sistema di raffreddamento della pila di ricarica in c.c.
Visualizza i dettagli -
Festeggiare il Capodanno e dare il benvenuto al nuovo anno
1278When the bells echo in the clear night sky,When the calendar turns to a new page,We are about to usher in a new year.Thanks for this year's harvestLet us have precious experience on our growthThere is always a reward for sweatThis yearWe sh...
Visualizza i dettagli -
Detailed explanation of closed circulation cooling system debugging attention
1158The preparation of the closed circulation cooling system before commissioning is an important part of the debugging process, which may affect the progress of the whole debugging process. Generally, attention should be paid to the leakage detection...
Visualizza i dettagli