For ultra-deep cold processing equipment, failure to pay attention to the use of the equipment may cause equipment failure.
Before using the water-cooled ultra-cry cryogenic treatment, it should be checked whether all the valves between the equipments are open, whether all the water tanks are filled with water, whether the fans are reversed, and whether the circulating water pump is running in the correct direction. Open the super deep crying treatment main power supply (the standard power supply is 3-phase five-wire system 380V 50HZ), specifically the water-cooled ultra-deep cold treatment front nameplate. Wuxi Guanya LNEYA reminds everyone that the power supply for ultra-deep cooling must be stable to avoid burning the unit or compressor and pump motor.
First open the ultra-deep cooling treatment cooling switch, then turn on the chilled water pump switch. Since the compressor has a delayed start function, the compressor will automatically run after the delay. At this time, pay close attention to the front control panel to observe the temperature change, as appropriate according to the cooling demand. Perform temperature adjustment. Water-cooled ultra-cry cryogenic treatment During normal operation, the unit operation data should be recorded periodically to facilitate the identification of problems based on data as soon as the unit fails. The ultra-cryogenic treatment itself is provided with multiple protection devices. Once there is a fault, it will start to protect and automatically stop. After the fault is removed, press the reset to operate normally.
When the super-cryogenic treatment is not used, the unit, water pump, insulated water tank and water in the pipeline should be drained, and the equipment should be covered and protected to avoid dust and other debris. Regarding the maintenance of ultra-deep cold treatment, this cannot be ignored. It is necessary to clean the condenser and evaporator after running for half a year. It is recommended to carry out maintenance of the whole machine after one year of operation, and keep it clean and clean regularly.
The instruction manual of the ultra-cryogenic treatment equipment and regular inspection and maintenance are all parts that the user needs to know in order to make the equipment run more efficiently.

Raccomandazioni correlate
-
Sistema di raffreddamento e riscaldamento del bollitore di dissoluzione per cristallizzazione da 200L
822Per le esigenze di 200L cristallizzazione dissoluzione bollitore raffreddamento e riscaldamento applicazioni di sistema, questo tipo di attrezzature è di solito utilizzato nella cristallizzazione, dissoluzione e altri processi nei settori dell'industria chimica, farmaceutica,...
Visualizza i dettagli -
Applicazione e principio di funzionamento del refrigeratore ad acqua
913Applicazione e principio di funzionamento del refrigeratore raffreddato ad acquaIl refrigeratore raffreddato ad acqua è un tipo di frigorifero industriale a bassa temperatura LNEYA di Wuxi Guanya. Un singolo compressore può raggiungere i -152 gradi Celsius di raffreddamento e refrigerazione. Potenza dell'apparecchiatura,...
Visualizza i dettagli -
Beginning with Refrigeration, Heating and Temperature Control System Product Diversification Develo
995Wuxi Guanya Refrigeration technology co., ltd was founded in 2006. It set up a refrigeration and heating equipment studio. In 2007, it launched the first generation refrigeration and heating cycle, registered the trademark "LNEYA". In 2008, it lau...
Visualizza i dettagli -
What is the reason for non condensable gas in the condenser of ultra-low temperature cooling water c
1430When the ultra-low temperature cooling water chiller is running, it is necessary to pay attention to the gas state generated by the condenser under a certain temperature and pressure. The existence of these gases affects the operation of the ultra...
Visualizza i dettagli