How to deal with the equipment failure alarm of the recirculation chiller
What to do if there is a failure and alarm
during the use of the recirculating chiller equipment? In order to ensure
production, such problems need to be resolved quickly.
We must first understand the causes of
failures and alarms, and adopt different solutions for different causes. Common
recirculation chiller equipment failures and alarms include reverse phase
alarm, contactor jam alarm, over-temperature protection alarm, abnormal
pressure alarm, overload alarm, etc. No matter what kind of fault alarm, it can
be known according to the alarm light and alarm signal information.
1. Recirculation chiller equipment reverse
phase alarm
When a reverse phase alarm occurs in the recirculation chiller
equipment, the circulating pump cannot be started. There are two reasons for
the reverse phase alarm of the high and low temperature cold water circulation
device. One is that the phase sequence of the three-phase power line is
connected incorrectly, and the other is that the reverse protector fails. If
the phase sequence of the three-phase power cord is connected incorrectly, just
adjust the phase sequence directly. If the reverse phase protector fails, it
needs to be replaced.
2. Contactor stuck alarm
Recirculation chiller equipment contactor
stuck alarm, the over-temperature indicator will also be on, generally there
are three reasons: one is the heating AC contactor stuck, the other is the
computer board heating has been outputting, there is a problem, and the third
is the over-temperature The protection switch operates incorrectly. When the
contactor is stuck and alarms, the continuous heating of the heat transfer oil
will cause danger, so deal with it in time.
3. Alarm for lack of media
In order to protect the heating pipe and circulating pump of the
recirculating chiller equipment, the system will stop heating when there is a
shortage of media. When there is a lack of media, check whether there is a lack
of media (water or oil). If the water temperature meter shows that there is a
lack of media, you can adjust the pressure value of the pressure switch to a
lower value.
4. Overload alarm
When the recirculation chiller equipment has an overload alarm,
check whether the circulating pump is overloaded. If the pump is overloaded,
you can increase the overload current ampere.
When the recirculation chiller equipment
fails and alarms, as long as it is dealt with in time, there will be no safety
issues. LNEYA is a manufacturer of recirculating chiller equipment, equipped
with an after-sales service system. For minor problems such as fault alarms,
you can consult us sales@lneya.com for a faster and safer solution.
Raccomandazioni correlate
-
Quali sono i refrigeranti per il congelatore a bassissima temperatura a 120 gradi?
1305I refrigeranti dei diversi produttori di congelatori a bassissima temperatura sono diversi. I refrigeranti comunemente utilizzati nelle apparecchiature di refrigerazione LNEYA sono R404, R22, ecc. Qual è la differenza tra i due refrigeranti a bassissima temperatura (120 gradi)?
Visualizza i dettagli -
The reason why the cooling water circulator needs the main water circulation
1170The supplement of the water cycle is directed to a water-cooled cooling water circulator, and the air-cooled cooling water circulator does not have this problem. The water-cooled cooling water circulator needs cooling water during normal operation...
Visualizza i dettagli -
Configuration form of circulating heating unit for laboratory
909The standard model of the circulating heating unit for LNEYA laboratory is: SUNDI, the temperature range is from room temperature to minus 120 degrees Celsius, and the capacity can be divided into 5L, 10L, 20L, 30L, 40L, 50L, 80L, 100L, larger cap...
Visualizza i dettagli -
The safety of heat transfer oil in water-cooled chillers
995In order to achieve better operating efficiency, water-cooled chillers need to choose branded heat transfer oil, but you need to pay attention to safe placement, a little carelessness will cause adverse effects. Although the heat transfer oil of t...
Visualizza i dettagli