How to Carry On Industrial Low Temperature Chillerstest Of Choosing The Better Company?
No matter what chillers are used, we need to constantly learn about the relevant knowledge of the industrial-low temperature chillers.
Which company’s low – temperature chiller is better? Let me tell you, in order to help you to use the industrial low temperature chillers, you have to know these related knowledge of test.
Temperature detection of inlet and outlet
When the industrial low temperature chiller is being used, the thermometer of the inlet and outlet of the system is checked through the control system of the unit half an hour after starting up, which can read the inlet temperature and outlet temperature of the industrial low-temperature chiller. Ensure that the temperature difference between inlet and outlet water is not too large, once it is too large, the water flow may be shown to be small, which may cause the normal operation of the industrial low-temperature chiller.
Water pressure detection of inlet and outlet pipes
It is necessary to test the outlet and inlet water pressure values of industrial low-temperature chillers, and then check the instructions to see how much water flow is under normal conditions to judge whether the refrigeration system is normal. Which company’s low – temperature chiller is better? Let me tell you. We can judge which section of the pipe resistance value is larger, and make the corresponding rectification plan from the line.
Detection of suction temperature of copper tube of compressor
When using industrial low – temperature chillers, after running for half an hour, If the suction temperature of the compressor is detected below 0 degrees, it indicates that the water flow in the heat exchanger does not reach a fixed value. It is easy to cause the drop of evaporation force, which may lead to the refrigerant still absorbing heat in the process of evaporator flowing to the compressor, resulting in the suction temperature of the compressor being lower than 0 degrees.
Current detection during pump operation
During operation, the industrial low – temperature chiller can compare the current in the water pump with the rated current of the chiller. In this way, it can judge whether the current is large or small and detect the operation status of the water system at any time.
These are the methods of testing which company’s industrial low -temperature chiller is better. I hope you can quickly find problems in the chiller when you check it.
Raccomandazioni correlate
-
Ways to make ultra-low temperature circulating chillers more energy-efficient
759In modern times, environmental protectionand energy saving is the development theme, so is the industrial chiller. Then,how to improve your industrial chiller to be more energy conservation? First, to prevent and reduce the pipescaling of ult...
Visualizza i dettagli -
Quali sono le caratteristiche della pressione dei refrigeratori d'acqua industriali?
1121Industrial water chillers are one of themost popular equipment in the machinery and equipment industry. For thisreason, the editor of LNEYA specially compiled relevant pressure instructionsto help everyone better understand industrial water chi...
Visualizza i dettagli -
We are LNEYA, a manufacturer of chillers
1240LNEYA chiller manufacturer is committed tothe R&D, production and sales of refrigeration and heating temperaturecontrol systems, ultra-low temperature freezers, new energy automobilecomponent testing systems, and heating cycle systems. The ...
Visualizza i dettagli -
Perché le macchine per la forgiatura devono essere dotate di un'unità di controllo della temperatura di raffreddamento e riscaldamento?
765Il controllo della temperatura del pezzo e dello stampo è fondamentale durante il processo di lavorazione delle macchine per la forgiatura e lo stampaggio, soprattutto durante le operazioni di lavorazione a caldo. L'applicazione di sistemi di raffreddamento, riscaldamento e controllo della temperatura in...
Visualizza i dettagli