Ricerca nell'intera stazione

Why do forging machines need to be equipped with cooling heating temperature control unit?

3.Mold Heating: In some cases, such as cold forging or warm forging, the mold may need to be preheated to a certain temperature to improve the fluidity of the metal and the friction conditions between the mold and the workpiece. Mold heating is usually achieved through electric heating elements (such as resistance wires, induction coils) or external heat sources (such as hot oil, hot air).

4.Local Heat Treatment: For certain forgings, local heat treatment (such as quenching and tempering) is required after forming to obtain the required mechanical properties. At this time, special local heating equipment (such as induction heater) and cooling devices (such as water spray, spray or immersion cooling) may be required.

5.Temperature Control System: The entire cooling and heating process is usually monitored and regulated by a temperature control system. The system includes temperature sensors, controllers, and driving devices for cooling/heating equipment. Sensors monitor the actual temperature of the mold or workpiece, and the controller automatically adjusts parameters such as cooling water volume, water pressure, and cooling medium temperature based on the set temperature curve and feedback signal, ensuring the accuracy and stability of temperature control.

  • SUNDI-320/420W/430W"      /&gt;<figcaption><span>Capacità di raffreddamento0,3kW~3kWPotenza di riscaldamento2kW~3kWGamma di potenza2,9kW~5kW</span></figcaption></figure></a></div><div class= SUNDI-320/420W/430W

    Capacità di raffreddamento 0,3kW~3kW Potenza di riscaldamento 2kW~3kW Gamma di potenza 2,9kW~5kW

    More
  • SUNDI -10℃~150℃"      /&gt;<figcaption><span>Capacità di raffreddamento1,5kW~15kWPotenza di riscaldamento2,5kW~15kWGamma di potenza3,6kW~20kW</span></figcaption></figure></a></div><div class= SUNDI -10℃~150℃

    Capacità di raffreddamento 1,5kW~15kW Potenza di riscaldamento 2,5kW~15kW Gamma di potenza 3,6kW~20kW

    More
  • SUNDI -25℃~200℃"      /&gt;<figcaption><span>Capacità di raffreddamento1kW~200kWPotenza di riscaldamento2,5kW~200kWGamma di potenza4kW~260kW</span></figcaption></figure></a></div><div class= SUNDI -25℃~200℃

    Capacità di raffreddamento 1kW~200kW Potenza di riscaldamento 2.5kW~200kW Gamma di potenza 4kW~260kW

    More
  • SUNDI -25℃~300℃"      /&gt;<figcaption><span>Capacità di raffreddamento1kW~200kWPotenza di riscaldamento2,5kW~200kWGamma di potenza4kW~260kW</span></figcaption></figure></a></div><div class= SUNDI -25℃~300℃

    Capacità di raffreddamento 1kW~200kW Potenza di riscaldamento 2.5kW~200kW Gamma di potenza 4kW~260kW

    More
  • SUNDI -45℃~250℃"      /&gt;<figcaption><span>Capacità di raffreddamento0,45kW~200kWPotenza di riscaldamento3,5kW~200kWGamma di potenza6,5kW~280kW</span></figcaption></figure></a></div><div class= SUNDI -45℃~250℃

    Capacità di raffreddamento 0,45kW~200kW Potenza di riscaldamento 3,5kW~200kW Gamma di potenza 6,5kW~280kW

    More
  • SUNDI -60℃~250℃"      /&gt;<figcaption><span>Capacità di raffreddamento0,25kW~60kWPotenza di riscaldamento2,5kW~60kWGamma di potenza5kW~95kW</span></figcaption></figure></a></div><div class= SUNDI -60℃~250℃

    Capacità di raffreddamento 0,25kW~60kW Potenza di riscaldamento 2,5kW~60kW Gamma di potenza 5kW~95kW

    More

caricamento...

已经是到最后一篇内容了!

REQUEST A QUOTE

Invia per la consultazione

Vi risponderemo entro 24 ore

*
*
正在提交!
提交成功!
提交失败!
邮箱错误!
电话错误!
Il precedente: Il prossimo:
Espandere di più!