Four Key Points of Water Cooled Chiller Installation
The installation of water-cooled chiller can be carried out from four aspects: first, the installation of chiller, then the installation of water pipe, water pipe cleaning and equipment insulation. Do not underestimate the installation of this part, which will directly affect the safe and stable operation of the water-cooled chiller. Here are four key installation points.

1. Installation of water-cooled chiller (mainly foundation anti vibration device)
We all know that a flat and spacious place must be selected for equipment installation, and the chiller is no exception. Many users will do a good job of foundation pouring and embed four horizontal sizing blocks before installing the chiller. Generally, the water chiller has four anchors. An adjusting base plate with two adjusting screw holes can be prepared for the anchors to adjust the levelness of the whole water chiller, and the extra gap after adjustment can be filled with concrete mortar. After the mortar is dry, the adjusting bolt can be removed, the positioning bolt can be left, and the fixing measures shall be taken for the chiller.
2. Installation of water pipe of water-cooled chiller
It is mainly the external water pipes of the evaporator and condenser. If it is a double return water pipe, it is arranged on the same side. If it is a single return or three return waterway, it is arranged on both sides. The inlet and outlet of the condenser and evaporator of the water-cooled chiller are from the bottom to the top. Remarks: water will be transported from the cooling water tower to the chiller and from the chiller to the cooled equipment through the water pump, so the water pipe installation must be carried out according to the installation diagram provided by the chiller manufacturer.
3. Water pipe cleaning of water-cooled chiller
After installing the water pipe for the equipment, the leakage test shall be conducted for the whole water system. After passing the leak test, the water pipe can be cleaned. When cleaning the water pipe, first confirm whether the placement direction of the water pump is correct, and open all inlet and outlet pipeline valves. After the pipeline is fully filled with water, start the chilled water pump and cooling water pump, stop the water pump after continuous operation for two hours, drain all cold water and clean the water pump filter.
4. Thermal insulation of water-cooled chiller
When the temperature in the system is lower than the ambient temperature, there will be a loss of refrigeration capacity. In order to reduce this loss, it is recommended to wrap a layer of thermal insulation material in the low-temperature part of equipment and pipelines. After the water-cooled chiller is installed and the system pressure test is carried out, the evaporator shell or evaporator water tank, compressor inlet pipe, return pipe, etc. shall be insulated.
Raccomandazioni correlate
-
Environmental Conditions for Installation of Air Cooled Chillers
1059As we all know, the installation of most machines needs to match the environment and conditions. Of course, our industrial air-cooled chillers are no exception. If the air-cooled chiller is not installed for the first time, it will bring a lot of ...
Visualizza i dettagli -
Chiller unit for power limit testing of new energy batteries
805Temperature control and heat dissipation: Batteries generate a large amount of heat during high load operation. Excessive temperature not only affects the performance of the battery, but also shortens its service life. T...
Visualizza i dettagli -
Piccolo accoppiamento per affrontare l'intasamento da ghiaccio dei refrigeratori a circolazione di liquido ad alta e bassa temperatura
808Nel funzionamento dei refrigeratori a circolazione di liquido ad alta e bassa temperatura, il blocco del ghiaccio è un guasto relativamente comune. Sulla base dell'esperienza dei produttori del settore, abbiamo raccolto alcuni suggerimenti per affrontare il problema dell'intasamento da ghiaccio. Nelle tubazioni...
Visualizza i dettagli -
The importance of chiller compressors
1090In the operation of the precision chiller, the compressor is a more important part. If we want to understand the chiller, we have to understand the compressor. Most precision chiller compressors have a thermal switch inside. The function of this s...
Visualizza i dettagli