Chiller unit for power limit testing of new energy batteries
The working principle of power limiting mode: When the system detects low battery level or high temperature, it will automatically enter power limiting mode to avoid excessive use of the battery and protect the battery and motor. Testing method: Evaluate the performance and stability of the battery in limited power mode by simulating these extreme conditions.
The main reason for requiring a chiller for power limit testing of new energy batteries is to ensure temperature control of the battery during high load operation.
In the testing of new energy batteries, the role of the chiller is mainly reflected in the following aspects:
Temperature control and heat dissipation: Batteries generate a large amount of heat during high load operation. Excessive temperature not only affects the performance of the battery, but also shortens its service life. The chiller provides a stable cooling water flow to help the battery dissipate heat in a timely manner, ensuring that the temperature of the battery is maintained within a suitable range during operation.
Simulate real working conditions: New energy batteries will have different temperature requirements in different working environments and conditions. The chiller can simulate various extreme temperature environments, such as high and low temperatures, to help test the performance of batteries at different temperatures. For example, a chiller can provide precise temperature control support for testing the starting performance of a battery in extremely cold environments or its ability to operate continuously under high temperature conditions.
Improving testing accuracy: Accurate temperature control is crucial for battery performance testing. The chiller can maintain a constant cooling temperature to avoid testing data errors caused by temperature fluctuations. By conducting temperature control tests on different operating states of the battery, researchers can more accurately evaluate key performance indicators such as efficiency, durability, and thermal stability of the battery.

LNEYA chillers are typically equipped with high-precision temperature sensors and controllers that can monitor the temperature of the coolant in real time and automatically adjust the operating status of the refrigeration system based on the set temperature value, ensuring that the temperature of the coolant remains within the set range. Equipped with advanced temperature control technology, it can achieve temperature control accuracy of ± 0.1 ℃ or even higher, meeting the strict requirements for temperature accuracy in lithium battery testing. It has multiple safety protection functions, such as overvoltage protection, overcurrent protection, overheating protection, antifreeze protection, etc., to ensure the safety of equipment and testing personnel.
Select a chiller with appropriate cooling capacity based on the power and heat dissipation requirements of lithium battery testing. Insufficient cooling capacity cannot meet the testing requirements, while excessive cooling capacity can result in energy waste and increased costs. Determine the required temperature range to ensure that the chiller can provide low-temperature coolant that meets the requirements of lithium battery testing. In terms of flow and pressure, it is necessary to consider the requirements of lithium battery testing equipment for coolant flow and pressure, and choose a suitable chiller model.
Prodotti consigliati
Serie di conversione di frequenza KRYZ
- 参数标题参数内容
Rated test conditions: dry bulb temperature 20℃; wet bulb temperature 16℃. Inlet water temperature 20℃; outlet water temperature 25℃. The data in this table is for reference only. Please refer to the …
Serie di riscaldamento a raffreddamento diretto KRY
- 参数标题参数内容
Rated test conditions: dry bulb temperature 20℃; wet bulb temperature 16℃. Inlet water temperature 20℃; outlet water temperature 25℃. The data in this table is for reference only. Please refer to the unit name…
Oil Cooling Chiller KRYO Series
- 参数标题参数内容
For the power battery charging management, the precision temperature control device for testing the permanent magnet synchronous motor, the switched reluctance motor, the asynchronous…
KRY -40℃~+100℃ (1to6)
- 参数标题参数内容
I componenti sono raffreddati e riscaldati internamente attraverso una soluzione acquosa di glicole etilenico per il test -40°C~100°C (espandibile fino a 150°C) Per la gestione della carica della batteria ...
KRY -40℃~+100℃ (1to1)
- 参数标题参数内容
Refrigerazione, riscaldamento, controllo della temperatura, controllo del flusso Collegare l'oggetto testato a una piattaforma di test adattatoreI componenti sono raffreddati e riscaldati internamente attraverso una soluzione acquosa di glicole etilenico per il test. ...
KRY -40℃~+100℃ (1to2)
- 参数标题参数内容
L'intervallo di temperatura è di -40℃~+100℃, che può essere esteso a +135℃ in base alla situazione reale, e la precisione del controllo della temperatura è di più o meno 0,5℃. L'apparecchiatura può controllare il flusso e la pressione in modo indipendente mentre...
KRY -40℃~+100℃ (1to3)
- 参数标题参数内容
Dimensioni (A) cm L'intervallo di temperatura è di -40℃~+100℃, che può essere esteso a +135℃ in base alla situazione reale, e la precisione del controllo della temperatura è di più o meno 0,5℃. L'apparecchiatura può controllare il flusso e...
KRY 0℃~+100℃ (1to2)
- 参数标题参数内容
L'intervallo di temperatura è 0℃~+100℃, che può essere esteso a +135℃ in base alla situazione reale, e la precisione del controllo della temperatura è di più o meno 0,5℃. L'apparecchiatura può controllare il flusso e la pressione in modo indipendente ...
KRY 0℃~+100℃ (1to3)
- 参数标题参数内容
Temperatura di prova dei principali elementi di prova dell'elettronica del veicolo: Condizioni di prova IC per le locomotive: -40℃~125℃, vento, esposizione al sole, forti vibrazioni; condizioni di test del pannello strumenti...
KRY 0℃~+100℃(1&6)
- 参数标题参数内容
Simulazione della temperatura per il test di qualità del veicolo: test di durata della batteria, banco di prova dell'iniettore/motore, test dell'airbag, banco di prova dei componenti, ecc. Può simulare le condizioni ambientali esterne del clima...