Compression Chillers vs. Absorption Chillers—Key Differences, Efficiency, and Applications

- Compression Chillers vs Absorption Chillers Key Differences Efficiency and Applications
- What Are the Common Types of Chiller Compressors
- Hidden Costs of Chillers Quotes
- Industrial Chiller vs Industrial Freezer
- What Are Water-Cooled Condensers
- Custom Chiller vs Standard Chiller
- Che cos'è un refrigeratore raffreddato ad aria
- Che cos'è un refrigeratore raffreddato ad acqua
- Agosto 2025
- Luglio 2025
- Giugno 2025
- Maggio 2025
- Marzo 2025
- Febbraio 2025
- Gennaio 2025
- Dicembre 2024
- Novembre 2024
- Ottobre 2024
- Settembre 2024
- Agosto 2024
- Luglio 2024
- Giugno 2024
- Maggio 2024
- Aprile 2024
- Marzo 2024
- Febbraio 2024
- Settembre 2023
- Luglio 2023
- Giugno 2023
- Maggio 2023
- Gennaio 2023
refrigeratore raffreddato ad aria refrigeratore refrigeratori Congelatore a freddo refrigeratore di raffreddamento circolatore di raffreddamento e riscaldamento sistema di raffreddamento e riscaldamento sistema di controllo dinamico della temperatura congelatore circolatore di riscaldamento refrigeratore industriale raffreddamento industriale congelatore industriale frigorifero industriale reattore a camicia refrigeratore a bassa temperatura notizie refrigeratore farmaceutico reattore refrigeratore raffreddamento del reattore raffreddamento del reattore riscaldamento riscaldamento del reattore raffreddamento circolatore refrigerato refrigeratore a vite refrigeratore per semiconduttori refrigeratore di prova per semiconduttori sundi tcu controllo della temperatura camera di prova termostato refrigeratore a bassissima temperatura refrigeratore di prova per veicoli refrigeratore d'acqua refrigeratore raffreddato ad acqua
Refrigeratori industriali are key equipment for achieving dynamic temperature control and rapid cooling. Chillers are generally classified into compression chillers and absorption chillers, based on the method used to drive the refrigerant cycle.
Compression chillers are the most common type. Scroll chillers, refrigeratori a vite, and centrifugal chillers are all common types of compression chillers because they rely on a compressor to compress the refrigerant to achieve refrigeration. Absorption chillers, on the other hand, use thermal energy to drive the refrigerant and absorbent to circulate refrigeration.
What are the specific differences between the two?
Aspect | Compression Chillers | Absorption Chillers |
Drive | Electric motor + compressor | Heat energy, no compressor |
Core Parts | Compressor, condenser, expansion valve, evaporator | Evaporator, absorber, pump, generator, condenser |
Efficiency (COP) | ~4.0, high efficiency | 0.6–1.2, lower |
Response | Fast, flexible load control | Slow, high thermal inertia |
Capacity Range | Small to large (labs → industry) | Large-scale only |
Energy Source | Electricity | Steam, hot water, waste heat |
Applicazioni | HVAC, semiconductor, pharma, labs | Central cooling, power, steel, chemical |
Costo | Lower purchase & maintenance | Higher cost & water use |
Drive Method and Refrigeration Principle Differences Between Compression and Absorption Chillers
Compression chillers rely on a mechanical compressor. When powered on, a motor drives the compressor’s rotor (for scroll or screw compressors) or impeller (for centrifugal compressors). The compressor draws in refrigerant gas, compressing it and raising both its temperature and pressure.
Il refrigerante is then discharged and enters the condenser, where it exchanges heat with cooling water or air, condensing into a liquid. The refrigerant then passes through an expansion valve to reduce pressure and temperature before entering the evaporator, absorbing the heat from the coolant.
In contrast, absorption chillers operate without a compressor, using thermal energy to circulate the refrigerant. Take a typical LiBr-H2O system as an example. After evaporating in the evaporatore, the refrigerant forms low-pressure vapor.
However, unlike the refrigeration cycle of a compression chiller, it does not enter the compressor directly. Instead, it is absorbed by the LiBr-H2O solution. The absorbent takes in the refrigerant vapor, generating a low-pressure area that is pumped to the generator.
Within the generator, heating with steam, hot water, or gas causes the refrigerant to separate from the solution. Because the vapor is released through heating, the refrigerant pressure is already elevated, eliminating the need for compression by a compressor and allowing it to be directly fed to the condenser for condensation. Absorption chillers also do not require expansion valve throttling, so the cooled refrigerant enters the evaporator for evaporation.


Structural Differences Between Compression and Absorption Chillers
Comparing the refrigeration principles of the two, you’ll find that their internal structures are different.
The core components of the compression chiller’s refrigeration cycle are the compressor, condenser, expansion valve, and evaporator. Since a compressor extracts and compresses the refrigerant, it’s essential in this system. The expansion valve plays a crucial role in lowering the pressure of the high-pressure liquid refrigerant.
However, an absorption chiller can create negative pressure by absorbing vapor in the absorbent, or it can increase pressure by releasing vapor through heated solution. In other words, the pressure change in the system is controlled by the absorbent and the pump, eliminating the need for a compressor and expansion valve. As a result, the main components include the evaporator, absorber, solution pump, generator, and condenser.

Explore high-efficiency and energy-saving chiller solutions!
Performance Differences Between Compression Chillers and Absorption Chillers
The performance differences between compression chillers and absorption chillers are generally reflected in cooling efficiency, response speed, and cooling capacity.
Compression chillers have higher energy conversion efficiency. While system type, configuration, and operating conditions vary, most units can maintain a COP of around 4.0. In particular, units equipped with variable frequency drives (VFDs) can maintain a high COP even at low loads.
Although many companies choose to use waste heat to power absorption chillers to save electricity, the overall COP of absorption chillers is still much lower, typically between 0.6 and 1.2.
Are you curious why most semiconductor fabs choose compression chillers over absorption chillers? This is because absorption systems have greater thermal inertia and cannot adjust capacità di raffreddamento in a timely manner according to load.
When loads fluctuate frequently, compression chillers, which can adjust cooling capacity in a timely manner by adjusting compressor speed and expansion valve opening, offer advantages.
Furthermore, screw, scroll, and centrifugal chillers are suited to different heat loads, allowing for a suitable compression chiller to meet specific needs, from small laboratories to large industrial applications. Absorption chillers are commonly used in large-scale centralized cooling systems ranging from several hundred to several thousand kilowatts.
Application Differences Between Compression and Absorption Chillers
Because different types of compression chillers cover a wide range of cooling capacities, they have a wide range of applications. Small scroll chillers are commonly found in laboratories and medical institutions. Large screw chillers are very common in building HVAC systems and in industries such as the chemical and pharmaceutical industries.
In short, whether you need cooling equipment from a few kilowatts to several hundred kilowatts, you can find a suitable model among compression chillers.
Absorption chillers have a relatively low electricity dependency, making them suitable for large-scale projects that prioritize energy savings, such as centralized cooling systems or those in the steel, chemical, and power industries seeking to utilize waste heat from factories.

Cost Differences Between Compression and Absorption Chillers
Absorption chillers generally have higher purchase costs than compression chillers due to their more complex design and additional internal components. Consequently, they require more maintenance time and costs. Regarding operating costs, the absorber in an absorption chiller requires water, resulting in higher water bills over time.
Conclusione
LNEYA is a Chinese chiller manufacturer specializing in the design and production of compression chillers. We offer refrigeratori scroll e refrigeratori a vite in a variety of performance levels, allowing us to tailor the optimal solution for your unique application.
Contact us for a product brochure and detailed quote.
Related Chillers
CONTATTO
TEL:TELEMATICO
EMAIL: EMAIL: EMAIL: EMAIL: EMAIL: EMAIL: EMAIL
WeChat e WhatsApp: il nostro servizio

Wechat QR

Hai domande o hai bisogno di un preventivo? Compila il modulo sottostante e il nostro team ti risponderà entro 24 ore.