Sistemi di raffreddamento e riscaldamento a frequenza variabile della serie SUNDIZ
APPLICAZIONI
Compared with SUNDI refrigeration system, the circulation system adopts variable frequency control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current compared to old products.
By increasing the frequency, the refrigeration power is increased and the cooling rate is improved by frequency conversion control of the circulation pump.
Caratteristiche del prodotto
Parametri del prodotto
SUNDIZ -45℃~250℃
Modello | SUNDIZ4-3 SUNDIZ4-3W |
SUNDIZ4-5 SUNDIZ4-5W |
SUNDIZ4-10 SUNDIZ4-10W |
SUNDIZ4-15W | SUNDIZ4-20W | SUNDIZ4-30W | |
Intervallo di temperatura | -45℃~250℃ | ||||||
Potenza di riscaldamento | 5,5kW | 7,5kW | 15kW | 25kW | 38kW | 60kW | |
Cooling capacity kW | 250℃ | 5,5kW | 7,5kW | 15kW | 25 kW | 38kW | 60kW |
20℃ | 5,5kW | 7,5kW | 15 kW | 25kW | 38kW | 60kW | |
-15℃ | 2.3kW | 3.6kW | 7.5 kW | 11kW | 15kW | 33kW | |
-35℃ | 0,9kW | 1,5kW | 3.3 kW | 5kW | 6,5kW | 10kW | |
Medium temp control accuracy | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Process temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Pump flow rate pressure max | 50L/min | 50L/min | 100L/min | 150L/min | 250L/min | 400L/min | |
2bar | 2bar | 2bar | 2,5 bar | 2,5 bar | 2,5 bar | ||
Refrigerante | R-404A / R507C Optional R448 | ||||||
Dimensione dell'interfaccia | G3/4 | G3/4 | G1 | DN32 PN10 | DN40 PN10 | DN50 PN10 |
SUNDIZ -80℃~250℃
Modello | SUNDIZ8-3W | SUNDIZ8-4W | SUNDIZ8-6W | SUNDIZ8-10W | SUNDIZ8-15W | |
Intervallo di temperatura | -80℃~250℃ | |||||
Potenza di riscaldamento | 3,5kW | 5,5kW | 7,5kW | 10kW | 15kW | |
Cooling capacity kW | 250℃ | 3,5kW | 5,5kW | 7,5kW | 15 kW | 20kW |
20℃ | 3,5kW | 5,5kW | 7.5 kW | 15kW | 20kW | |
-60℃ | 1.3kW | 1,8kW | 3 kW | 5,5kW | 8kW | |
-75℃ | 0.4kW | 0,6kW | 1 kW | 1,8kW | 2.7kW | |
Medium temp control accuracy | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Process temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Pump flow rate pressure max | 35L/min | 50L/min | 100L/min | 150L/min | 250L/min | |
2bar | 2bar | 2bar | 2,5 bar | 2,5 bar | ||
Refrigerante | R-404A / R508B |
Common Configuration
Visualizzazione della pressione del sistema | The pressure of the refrigeration system and circulation system is detected by pressure sensors and displayed on the touch screen | ||||
Controllore | Siemens S7-1200 PLC, fuzzy PID control algorithm, equipped with process dynamic control algorithm | ||||
Controllo della temperatura | Thermal medium outlet temperature control mode, external temperature sensor: (PT100 or 4-20mA or communication given) control mode (process dynamic control algorithm) |
||||
Programmabile | 25 programs, each program can edit 85 steps | ||||
Communication Protocol | Ethernet interface TCP/IP protocol, RS485 interface, MODBUS protocol | ||||
Internal temp feedback | Equipment thermal conductivity medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (for water-cooled equipment) |
||||
External temp feedback | Pt100 or 4-20mA or communication given | ||||
During cascade control Temp difference control function |
The temp difference between the outlet temp of the thermal oil and the external temp sensor can be set and controlled The temp difference between the inlet and outlet of the equipment can be set and controlled to ensure system safety |
||||
Closed circulation sistema |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
||||
Riscaldamento | Si riferisce alla potenza massima di riscaldamento del sistema (a seconda dei modelli). Il riscaldatore è dotato di una tripla protezione e di un limitatore di temperatura indipendente per garantire la sicurezza del sistema di riscaldamento; Using a voltage regulator to control the heating output and reduce the output current of the heater during process temperature control |
||||
External circulation Flow pressure | Brand magnetic drive variable frequency pump | ||||
Compressore | Emerson, Mitsubishi and other variable frequency compressors | ||||
Convertitore di frequenza | Famous brands such as ABB | ||||
Evaporatore | 316L Plate Heat Exchanger | ||||
Accessori per la refrigerazione | Danfoss/Emerson accessories (dry filters, oil separators, high and low pressure protectors, expansion valves) | ||||
Pannello operativo | Schermo tattile a colori da 7 pollici personalizzato LNEYA, visualizzazione della curva di temperatura | ||||
Protezione di sicurezza | Multiple self-diagnosis function; freezer overload protection; high/low pressure switch; overload relay, thermal protection device etc | ||||
Water-cooled condenser | Scambiatore di calore a piastre | ||||
Materiale della scocca | Cold rolled sheet (standard color 7035) | ||||
Potenza | 380V 50HZ / 460V 60HZ |
PRINCIPIO DI FUNZIONAMENTO

La tecnologia di raffreddamento ad altissima temperatura può raffreddare direttamente da una temperatura elevata di 300℃[perché solo il mezzo di trasferimento del calore nella camera di espansione entra in contatto con l'ossigeno dell'aria (e la temperatura del serbatoio di espansione è compresa tra la temperatura normale e 60℃), il che può ridurre il rischio di ossidazione del mezzo di trasferimento del calore e di assorbimento di acqua nell'aria. Ad alta temperatura, il mezzo di conduzione del calore non evapora e il controllo continuo della temperatura di - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ e - 30℃ ~ 300℃ può essere realizzato senza pressurizzazione.
Color Screen Control

1. Visualizza tutti i tipi di temperature di controllo del processo.
2. Indica il livello del liquido del fluido termovettore nel vaso di espansione.
3. Mostra l'indicazione del funzionamento del sistema di refrigerazione.
4. Mostra l'indicazione del funzionamento del riscaldatore.
5. Indica il funzionamento della pompa di circolazione.
6. Visualizza il controllo della temperatura (modello di controllo della temperatura dei materiali, controllo della temperatura media di conduzione del calore).
7. È possibile impostare il controllo del limite superiore e inferiore della temperatura.
8. È possibile impostare la differenza di temperatura tra la camicia e il materiale del reattore.
9. Mostra l'allarme per aggiungere il liquido quando è vuoto.
10. Il compressore di refrigerazione può essere impostato per funzionare manualmente o automaticamente.
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
Che si tratti di refrigeratori portatili, compatti, grandi o piccoli, possiamo progettarli su misura in base alle vostre esigenze. Indipendentemente dal numero di tonnellate di refrigeratori di cui avete bisogno, possiamo creare la soluzione migliore.
CUSTOM CHILLER TYPES
Forniamo refrigeratori di vari tipi di refrigerazione, tra cui, ma non solo, refrigeratori raffreddati ad aria, ad acqua e a condensazione evaporativa. Indipendentemente dal tipo di compressore di refrigerazione, possiamo progettarlo in base alle vostre esigenze.
CUSTOM TEMPERATURE RANGES
Possiamo creare una soluzione personalizzata per temperature da -150℃ a +350℃. Intervalli di temperatura personalizzati per settori specifici.
CUSTOM CHILLER VOLTAGE
Personalizzare la tensione e la fase del refrigeratore in base alle proprie esigenze. Opzionale 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, ecc.
Perché scegliere lneya come fornitore di controllo della temperatura?
Anni di esperienza
Clienti soddisfatti
m² Area di produzione
Tecnologie brevettate
Visita la fabbrica LNEYA
contattateci
Inviateci la vostra richiesta e vi contatteremo entro 24 ore.