![](https://www.lneya.com/wp-content/uploads/2024/11/chamber-1024x213.jpg)
LNEYA’s test chamber can simulate various temperature and humidity environments, and is suitable for high and low temperature tests, wet heat tests, etc. This test chamber has a very wide temperature and humidity range and extremely high control accuracy. It can meet the national standard GB and IEC related test standards. The programmable constant temperature and humidity test chamber is used to test the heat resistance, cold resistance, dry resistance and moisture resistance of various materials. It is suitable for testing the quality of products such as electronics, electrical appliances, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, medical treatment, and aerospace.
New energy battery test CHAMBER
Model | GD-9000-2-B1-KRYCH-4A15W | GD-9000-2-B1-KRYCH-475W | GD-9000-2-B1-KRYCH-4A10W | GD-1000-B1-KRYCH-475 | |||||
Temperature range | -40℃~100℃ Antifreeze |
-40℃~100℃ Test chamber |
-40℃~100℃ Antifreeze |
-40℃~100℃ Test chamber |
-40℃~100℃ Antifreeze |
-40℃~100℃ Test chamber |
-40℃~100℃ Antifreeze |
-40℃~100℃ Test chamber |
|
Antifreeze flow control | 1L/min~40L/min | 1L/min~25L/min | 1L/min~25L/min | 1L/min~10L/min | |||||
±0.2L/min | ±0.2L/min | ±0.2L/min | ±0.2L/min | ||||||
Antifreeze pressure | Measure and display the inlet and outlet pressure, as well as the pressure displayed on the touch screen | ||||||||
Chamber(W*H*D) | Upper cavity cm | 220*322*120 | 220*322*120 | 220*322*120 | Single cavity:100*100*100 | ||||
Lower cavitycm | 220*322*110 | 220*322*110 | 220*322*110 | ||||||
Heating power | 15kW | 14kW | 7.5kW | 14kW | 10kW | 14kW | 7.5kW | 6kW | |
Cooling capacity Antifreeze |
135℃ | 15kW | 7.5kW | 10KW | 7.5kW | ||||
20°℃ | 15kW | 7.5kW | 10KW | 7.5kW | |||||
0℃ | 15kW | 7.5kW | 10KW | 7.5kW | |||||
-20℃ | 10kW | 4.5kW | 6KW | 4.5kW | |||||
-35℃ | 4kW | 1.8kW | 2.5KW | 1.8kW | |||||
Chamber | Heating rate | 25~+100℃≥±2℃/Min (No load, average throughout the entire process) (Customizable at 5~25℃) | |||||||
Cooling rate | 25~-40℃≥1℃/Min(No load, average throughout the entire process) (Customizable at 5~25℃) | ||||||||
Antifreeze temp control accuracy | ±0.1℃ | ||||||||
Temperature uniformity | ≤±1℃(unloaded) | ||||||||
Circulating air volume | 5000m³/h | 2500m³/h | |||||||
Cooling water 20 ℃ | 25m³/H | 20m³/H | 20m³/H | 7m³/H | |||||
Dimension cm | 240*560*285 | 240*560*285 | 240*560*285 | 120*205*205 | |||||
Bearing | 1500kg | 1500kg | 1500kg | 120kg | |||||
Weight | 4600kg | 4200kg | 4200kg | 600kg |
Rapid temperature change test chamber
Model | GD-500-B-KS | GD-1000-B-KS | GD-500-C-KS | GD-500-C-KS |
Temperature range | -40℃~+150℃ | -80℃~+150℃ | ||
Inner box size (W*H*D) cm | 90*65*90 | 100*100*100 | 90*65*90 | 100*100*100 |
Heating rate | (+20~+150℃)A:5℃/min(Customizable at 15~25℃),5℃/min Adjustable nonlinearity | |||
Cooling rate | (Carrying idler)(+20~-40℃)5℃/min | (Carrying idler)10℃/min(Customizable at 15~25℃) | ||
Temperature uniformity | ≤±1℃(unloaded) | |||
Temperature fluctuation | ≤±0.5℃ | |||
Temperature accuracy | ≤±0.1℃ | |||
Window size cm | 30*45 | 45*49 | 30*45 | 45*49 |
Two-layer test chamber
Model | GD-300-2-B1-LX | |
Inner box size (W*H*D) cm | Upper chamber cm | 85*60*60 |
Lower chamber cm | 85*60*60 | |
Temperature range | -40℃~100℃ (-70 ℃ can be customized) | |
Heating rate | (No load) (+20 ℃~150 ℃) 1 ℃/min (Customizable at 5-25 ℃) | |
Cooling rate | (No load) (+20 ℃~-40 ℃) 1 ℃/min (Customizable at 5-25 ℃) | |
Temperature uniformity | ≤±1℃(unloaded) | |
Temperature fluctuation | ≤±0.5℃ | |
Temperature accuracy | ≤±0.1℃ | |
Window size cm | 300*450 | |
Cryogen | R404A | |
Test hole | φ100mm×1 | |
Heater | Electric heating |
Two-layer impact test chamber
Model | GD-200-2-B-CJ | GD-400-2-B-CJ | |
Basket size (W * H * D) cm | 60*60*60 | 90*65*70 | |
Impact temperature range | Low temperature | -40~0℃ | |
High temperature | +60~+150℃ | ||
Heating rate of preheating zone | (No load) 5 ℃/min (customizable for 10-25 ℃) | ||
Cooling rate of pre cooling zone | (No load) 2 ℃/min (customizable for 5-25 ℃) | ||
Pre cooling area Pre cooling range | -10℃~-55℃ | ||
Preheating area preheating range | +60~+180℃ | ||
Residence time | ≥30min | ||
Recovery time | ≤ 5 minutes to recover to within ± 2 ℃ | ||
Temperature fluctuation | ≤1℃ | ||
Residence time | ≥30min | ||
Basket conversion time | ≤10S | ||
Window size cm | 300*450 | ||
Cryogen | R404A/R23 | ||
Heater | Electric heating |
Left & right multi-layer test chamber
Model | GD-518-2-C-DC | |
nside dimensions (W*H*D) |
Left cavity cm | 60*124.5*65 |
Right cavity cm | 60*124.5*65 | |
Temperature range | -80℃~150℃ | |
Heating rate | (No load) -40 ℃ →+125 ℃ 1 ℃/min (customizable for 5-25 ℃) | |
Cooling rate | (No load) 125 ℃ → -40 ℃ 1 ℃/min (customizable for 5-25 ℃) | |
Temperature uniformity | ≤±1℃(unloaded) | |
Temperature accuracy | ≤±0.1℃ | |
Cryogen | R404A/R23 | |
Heater | Electric heating |
Walk-in test chamber
Model | GD-8000-C-BR | ||
Inner box capacity | 8000L | ||
Inner box size (W*H*D) cm | 200*200*200 | ||
Outer box size (W*H*D) cm | 224*242*350 | ||
Temperature range | -80~+150℃ | ||
Temperature uniformity | ≤±1℃(unloaded) | ||
Temperature fluctuation | ≤1℃ | ||
Temperature accuracy | ≤±0.1℃ | ||
Heating rate | (No load) 1 ℃/min adjustable nonlinearity; (Customizable at 5-25 ℃) | ||
Cooling rate | (No load) 1 ℃/min adjustable nonlinearity; (Customizable at 5-25 ℃) | ||
Cryogen | R404A/R23 | ||
Test hole | φ100mm×1 | ||
Heater | Electric heating | ||
Window size cm | 450*490(2 pieces) |
Constant temperature & humidity test chamber
Model | GD-500-C-WS | GD-1000-C-WS | |
Inner box size (W*H*D)cm | 90*90*65 | 100*100*100 | |
Temperature range | -80~+150℃ | ||
Heating rate | (No load) (+20~150 ℃) 2 ℃/min (Customizable at 5~25 ℃) | ||
Cooling rate | (No load) (+20~-70 ℃) 1 ℃/min (Customizable at 5-25 ℃) | ||
Temperature uniformity | ≤± 1 ℃ (unloaded) | ||
Humidity fluctuation | ±3.0%RH(>75%RH);±5.0%RH(≤75%RH) | ||
Temperature fluctuation | ≤±1℃ | ||
Humidity accuracy | ≤±2.0%RH | ||
Temperature accuracy | ≤±0.1℃ | ||
Inner box material | SUS304 stainless steel | ||
Outer box material | Cold-rolled steel plate+spray coating | ||
Insulation material | Glass fiber cotton&polyurethane | ||
Window size cm | 30*45 | 45*49 | |
Cryogen | R404A/R23 | ||
Test hole | φ100mm×1 | ||
Heater | Electric heating |