Wuxi Guanya Refrigeration Technology co., ltd

Screw Chiller

  • FL-WS 5℃~30℃

    FL-WS 5℃~30℃

    August 27, 2018Specification1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.2.Due to continuous updating of produ...view
  • FL-WD 5℃~30℃

    FL-WD 5℃~30℃

    August 27, 2018Specification1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.2.Refrigerant is R22, if you want to ...view
  • FL-ZS 5℃~30℃

    FL-ZS 5℃~30℃

    August 27, 2018Specification:1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 30 ° C.2.Refrigerant is R22, if you want to...view
  • FL-ZD 5℃~30℃

    FL-ZD 5℃~30℃

    August 27, 2018Specification:1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 30 ° C.2.Refrigerant is R22, if you want to...view
  • LC-WS -25℃~5℃

    LC-WS -25℃~5℃

    August 27, 2018Specification:1.The standard design conditions are: chilled water:outlet water temperature -20 ° C, return water temperature -15 ° C; condensing temperature 40 ° C.2.Refrigerant is R404A.3.Due to c...view
  • LC-ZS -25℃~5℃

    LC-ZS -25℃~5℃

    August 27, 2018Specification:1.The standard design conditions are: chilled water:outlet water temperature -20 ° C, return water temperature -15 ° C; condensing temperature 40 ° C.2.Refrigerant is R404A.3.Due to c...view
  • Characteristics of the evaporator of LNEYA screw chiller

    Characteristics of the evaporator of LNEYA screw chiller

    October 11, 2018The evaporator of LNEYA screw chiller is a very important component in the four major parts of refrigeration. The low-temperature condensing "liquid" body passes through the evaporator and exchanges heat with the outside air to "heat" and absorb heat to aview
  • The consequences of the screw refrigerator not returning oil and the treatment method

    The consequences of the screw refrigerator not returning oil and the treatment method

    October 30, 2018The screw chiller handles liquid cooling in the petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical and other industries, so the cooling effect is very critical. If the screw chiller does not return oil, it will lead to poorview
  • Process description of LNEYA screw chiller

    Process description of LNEYA screw chiller

    January 3, 2019LNEYA screw chiller is suitable for all kinds of chemical, pharmaceutical, mechanical and other fields of production process cold source, can provide -25 ° C ~ 30 ° C chilled water, can be used as i...view
  • How to check the air tightness of 40 screw freezer?

    How to check the air tightness of 40 screw freezer?

    January 16, 2019Air tightness is related to the cooling effect of the entire 40-screw freezer. Therefore, the manufacturer of 40-pin screw freezer of LushiA (LNEYA) recommends that users do 4 inspections, then how to...view
products
Contact US
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China