Wuxi Guanya Refrigeration Technology co., ltd
SUNDI -60℃~300℃

SUNDI -60℃~300℃

  • SUNDI -60℃~300℃
  • Dynamic Temp Control Systems-2.jpg
  • Dynamic Temp Control Systems-1.jpg
SUNDI -60℃~300℃


  • Product Description
  • System Introduce
  • Technical Parameter

A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand   for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60℃. Therefore, during the process the risk of imbibing and volatilization of the heat conducting medium is reduced. There following advantages for the user.

Model SUNDI-655WV SUNDI-675WV SUNDI-6A10WV SUNDI-6A15WV SUNDI-6A25WV
Temp. range -60℃~+300℃ (system add pressure 3BAR)
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp control and jacket temp control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 42 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp of three points: the inlet and outlet of equipment,  reactor material temp(external temp sensor)
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 5.5 7.5 10 15 25
Cooling capacity kW at 300℃ 5.5 7.5 10 15 25
100℃ 5.5 7.5 10 15 25
20℃ 5.5 7.5 10 15 25
-20℃ 4.8 6 8.2 12 25
-40℃ 2.3 3.1 4.8 7.8 18
-55℃ 0.75 0.9 1.5 2.8 6
Circulation pump max
L/min bar
50 50 110 110 150
2 2 2.5 2.5 2.5
Pump LNEYA magnetic drive pump
Compressor Tecumseh closed compressor Dorin semi-closed compressor
Expansion valve Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R23 mixture,optional: R125/R23 mixture
Connection size G3/4 G1 G1 G1 DN32 PN10
Water-cooled type W(cooling water@20℃) 1800L/H
1.5bar~4bar
2100L/H
1.5bar~4bar
3000L/H
1.5bar~4bar
4000L/H
1.5bar~4bar
8.5m³/H
1.5bar~4bar
Dimension cm 55*95*170 55*95*170 70*100*175 80*120*185 100*150*185
Weight kg 265 305 340 380 980
Power 380V 50HZ 10kW 14kW 18kW 26kW 40kW
PRODUCTION WORKSHOP REAL MAP:

Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.



Related Products
  • Water Cooled Chiller

    Water Cooled Chiller

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
Leave a Message Email Us

we will contact you within 24 hours.

products
Contact
Tel: + 86 18751546043
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China