ZLJ -40℃~-15℃
Air cooled chiller for semiconductor production process- Compressor1.5hp~7hp
- RefrigentR404A R507C R448
- Power range380V 50HZ can choose 220V
- Temperture accuracy±0.5℃
Product data download

Configuration Details
Model | ZLJ-41.0 | ZLJ-41.5 | ZLJ-42 | ZLJ-43 | ZLJ-44 | ZLJ-46 | ZLJ-48 |
ZLJ-41.0W | ZLJ-41.5W | ZLJ-42W | ZLJ-43W | ZLJ-44W | ZLJ-46W | ZLJ-48W | |
Temperature range | -40℃~-15℃ | ||||||
Temperature control accuracy | ±0.5℃ control evaporation temperature | ||||||
Throttling method | Electronic expansion valve | ||||||
Controller | Siemens PLC | ||||||
Show record | 7-inch touch screen, record temperature, system pressure and other information | ||||||
Main components | Danfoss filter drier, Castor solenoid valve, Johnson Controls pressure sensor, EBM fan (air-cooled), Danfoss/Emerson oil separator, | ||||||
Compressor | Secop, Taikang, Emerson, Carlisle | ||||||
Refrigerant | R404A Optional R507C R448 | ||||||
High temperature cooling | With 150 degrees high temperature direct cooling technology, to meet the goal of rapid cooling ability during high temperature operation | ||||||
Compressor | 7/8HP | 1.5HP | 2HP | 3HP | 4HP | 6HP | 8HP |
Power supply V | 220V 50HZ | 380V 50HZ Can be customized 220V |
Model |
ZLJ-81.0 ZLJ-81.0W |
ZLJ-81.5 ZLJ-81.5W |
ZLJ-82 ZLJ-82W |
ZLJ-83 ZLJ-83W |
ZLJ-84 ZLJ-84W |
ZLJ-86 ZLJ-86W |
ZLJ-88 ZLJ-88W |
Temp Range |
-80℃~-50℃ |
||||||
Temperature Control Accuracy |
±0.5℃ control evaporation temperature |
||||||
Refrigerated @-70℃ |
0.37kW |
0.5kW |
0.75kW |
1.1kW |
1.5kW |
2.6kW |
3.1kW |
Refrigerant |
R404A/R508B |
||||||
High Temperature Cooling |
Possess high-temperature 150°C direct cooling technology to meet the target and quickly cool down during high-temperature operation |
||||||
Power |
220V 50HZ |
380V 50HZ 220V can be customized |
|||||
Breaker |
10A |
16A |
25A |
16A |
16A |
25A |
32A |
Product Description
The product directly outputs and evaporates the refrigerant in the refrigeration system into the target control element (heat exchanger) for heat exchange, thereby cooling the target control object. Compared with the fluid (gas) transported into the heat exchanger, the heat exchange capacity is generally more than 5 times higher, which is especially suitable for applications where the heat exchange area of the heat exchanger is small but the heat exchange capacity is large.
The direct-cooling refrigerator can also be used as gas capture, the refrigerant is directly passed into the trap to evaporate, and the gas in the space is quickly captured through the condensation effect on the surface of the trap.




Applications


You may also be interested in these products
MD -75℃~225℃
Thermal chuck or Thermal plate/Thermal control unit for ic test cooling
FLT -80℃~+80℃ Reverse ltricat Refrigeration
Cooling Power 0.6~3kW Heating Power 2~3.5kW Flow Control 12~45L/min Heat Transfer Oil Fluorinated fluid
FLTZ -30℃~40℃ Double Frequency Conversion
Temperture accuracy ±0.1℃ Cooling Power 5~11kW Heating Power 2.5kW
FLT -45℃~40℃
Temperture accuracy ±0.1℃ Cooling Power 6~40kW Refrigent R410A
loading…
已经是到最后一篇内容了!