Antifreeze Cooling&Heating Flow Control System

Antifreeze Cooling&Heating Flow Control System

Antifreeze Cooling&Heating Flow Control System


  • Product Description
Temperature control range:-40 ° C ~ 135 ° C

Power range:7.5kw

Temperature control accuracy:±0.3°C

This equipment combines high and low temperature test chamber and antifreeze refrigeration heating flow system to provide high temperature and low temperature antifreeze and antifreeze flow and pressure control and 1000L high and low temperature test environment for new energy vehicle battery pack. The battery pack can be tested in a high environment, and the battery pack is provided with high temperature, low temperature, control flow, pressure, and the like. The temperature is -40 degrees to 130 degrees antifreeze temperature, antifreeze flow control 2~20L/min, and the environmental chamber provides -45 degrees to 100 degrees.

 The refrigeration unit mainly includes a refrigeration compressor, a condenser, an oil separator, an intermediate heat exchanger, an internal circulation fan of the tank, a drying filter, a condenser, an evaporator, a throttle mechanism, an expansion tank, and an electric control.

Model KRYCH-15W
KRYCH-15
Temp Range -40℃~135℃ Anti-freeze fluid -45℃~100℃ Test bin
Antifreeze flow control 2L/min~20L/min ±0.2L/min
Antifreeze pressure Measuring the inlet and outlet pressure and displaying the pressure on the touch screen
Volume of test chamber 1000*1000*1000   1m3
Heating power 7.5kW Anti-freeze fluid 5kW Test bin
Refrigerating Output
Anti-freeze fluid
135℃ 7.5kW
20℃ 7.5kW
0℃ 7.5kW
-20℃ 4.5kW
-30℃ 2.5kW
-35℃ 1.8kW
Refrigerating output
Test bin
100℃ 6kW
-20℃ 3.5kW
-40℃ 1.2kW
Temp control precision of antifreeze ±0.3℃
High & low temp cavity temp control ±0.3℃
Test chamber internal circulating air 3500m3/h
When the door is opened, the internal circulation fan is automatically closed, and the screen on the touch screen will show that it is in the open state.
Controller Siemens PLC, Fuzzy PID Control algorithm
Communicating protocol Ethernet Interface TCP/IP Protocol
Internal temperature feedback Equipment tank internal temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured).
Heat The maximum heating output power of the system (according to each model);
The heater has triple protection and independent temperature limiter to ensure the safety of heating system
Heating power 15kW adopts regulator, heating power output control adopts 4~20mA linear control.
Refrigerating capacity Refers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures.
High temp cooling module The module can be cooled from 150 ℃ at high temperature.
Circulating pump flow Magnetic driving pump with LNEYA
Source 380V50HZ 23kW max
Shape dimension 1250*2350*1900 Same size of air-cooled water without outburst
Compression engine Emerson Valley Wheel Vortex flexible Compressor
Evaporimeter Adopting DANFOSS Plate Heat Exchanger / High strength Plate Heat Exchanger
Refrigeration Accessory Emerson / Danfoss brand dry filter, pressure control, oil separator, etc.
Expansion valve Danfoss thermal expansion valve / Emerson electronic expansion valve
Operation panel 7-inch color touch screen, temperature curve display\ EXCEL data export
Safe guarding With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
Cryogen R-404A/R507C
Reserved antifreeze interface inside the box G3/4 And globe valves
Water-cooled type W Type W is water cooled
Water-cooled condenser Double-pipe (heat) exchanger
Cooling water 32℃ 6m³/H
Shell material Cold rolled sheet spray (Standard Colour 7035)


The system process flow is as follows:

The liquid refrigerant in the evaporator of the unit is exchanged with the circulating air in the interior of the tank. The temperature rises from liquid to gas, and is sucked into the suction port of the compressor. The high-temperature and high-pressure refrigerant gas after compression by the compressor passes through The oil separator separates the refrigerating machine oil carried in the compression process, and then enters the condenser, and exchanges heat with ambient air or cooling water to change from high temperature and high pressure gas to high pressure normal temperature liquid. The high-pressure normal temperature refrigerant liquid is dried by a filter and then throttled and depressurized by an expansion valve, that is, from a high-pressure liquid to a low-pressure liquid. The low-pressure liquid (lower boiling point) enters the evaporator of the unit, and the cooling air is brought to the inside of the tank by the circulating air to achieve refrigeration.

The anti-freeze solution is injected into the 80L pressure vessel, and the fully closed circulation system is adopted. This avoids the opportunity for the antifreeze to contact with the outside air and ensures the condensation of the water. After the expansion tank is protected by nitrogen, the temperature range of the heat transfer liquid is also broadened because its boiling point is increased. In addition, oxidation of the thermally conductive liquid in contact with oxygen in the environment is also avoided, thereby extending the useful life of the thermally conductive liquid.