Wuxi Guanya Refrigeration Technology co., ltd

Notes on Purchasing Low Temperature Chamber

Question 1: How to calculate the estimated life of the product through its equipment?
Description: Can the equipment be used to calculate and estimate the possible service life of the product?

Question 2: Why do some shocks overheat?
Explanation: Why do some shocks have to be over normal temperature, while some shocks do not need to be over normal temperature? What is the effect of over normal temperature impact test on products?

Question 3: Is the temperature sensor of the low temperature chamber located in the test area or in the air duct?
Description: The temperature sensor of its equipment should be placed in the test area or in the air duct?

Question 4: Can the use of ovens and freezers replace the cold and heat shock machine for testing?
Explanation: If you do not have enough money to buy a cold and hot shock machine, can you use oven and freezer to replace the cold and hot shock machine by manual handling?

Question 5: How to determine the residence time of temperature shock test?
Explanation: In the impact process, there is a so-called residence time. How to determine the residence time of the sample to be tested depends on the quantity of the sample to be tested or the material to be measured?

Question 6: How long does the test furnace wall need to be wiped?
Explanation: How long does the test furnace wall need to be wiped, annual maintenance or quarterly maintenance or weekly maintenance, if not wiped, what will happen?

Welcome to buy our high quality low temperature chamber.
Related News
Related Products
  • Water Cooled Chiller

    Water Cooled Chiller

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Low Temperature Chiller

    Low Temperature Chiller

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • Wafer Test Chiller

    Wafer Test Chiller

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • Chip Test Heating Cooling System

    Chip Test Heating Cooling System

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact
Tel: + 86 13358153746
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat