Question 1: How to calculate the estimated life of the product through its equipment?
Description: Can the equipment be used to calculate and estimate the possible service life of the product?

Question 2: Why do some shocks overheat?
Explanation: Why do some shocks have to be over normal temperature, while some shocks do not need to be over normal temperature? What is the effect of over normal temperature impact test on products?

Question 3: Is the temperature sensor of the low temperature chamber located in the test area or in the air duct?
Description: The temperature sensor of its equipment should be placed in the test area or in the air duct?

Question 4: Can the use of ovens and freezers replace the cold and heat shock machine for testing?
Explanation: If you do not have enough money to buy a cold and hot shock machine, can you use oven and freezer to replace the cold and hot shock machine by manual handling?

Question 5: How to determine the residence time of temperature shock test?
Explanation: In the impact process, there is a so-called residence time. How to determine the residence time of the sample to be tested depends on the quantity of the sample to be tested or the material to be measured?

Question 6: How long does the test furnace wall need to be wiped?
Explanation: How long does the test furnace wall need to be wiped, annual maintenance or quarterly maintenance or weekly maintenance, if not wiped, what will happen?

Welcome to buy our high quality low temperature chamber.
Related News
Related Products
  • Water Cooled Chiller SLJ

    Water Cooled Chiller SLJ

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temperature Test Chamber

    High-Low Temperature Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • Humidity Test Chamber

    Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
  • Single Fluid Heat Transfer TCU SR

    Single Fluid Heat Transfer TCU SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Material TCU ZLF

    Reactor Material TCU ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Small Gas Condensing System

    Small Gas Condensing System

    April 10, 2018ModelHQ-0540HQ-1040HQ-2540HQ-5040HQ-0575WHQ-1075WHQ-2575WHQ-5075WGas flow5m3/h10m3/h25m3/h50m3/h5m3/h10m3/h25m3/h50m3/hLowest Temp.-40℃-40℃-40℃-40℃-75℃-75℃-75℃-75℃Primary Temp.There is no-20℃...view
products
Contact
Tel: + 86 13912479193
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat