What is a laboratory glycol chiller What should I pay attention to

The laboratory glycol chiller is a common cooling equipment in the laboratory. It is generally used to achieve the temperature requirement of the cold source. What are the benefits?

1. Why choose a laboratory glycol chiller:

The single-machine self-cascade refrigeration technology adopted has fast refrigeration speed, low noise and simple installation. There are many sizes and models of laboratory low-temperature refrigeration cycle devices. Users can choose models according to their own needs, and can also choose isolation and explosion-proof options.

2. Commonly used refrigerants in laboratory glycol chillers:

Commonly used water, brine, chlorinated solution, and ethylene glycol in laboratory cryogenic refrigeration cycle devices, the performance, price, and heat capacity of each refrigerant are different, so the choice can be selected according to the needs.

The freezing point of ethylene glycol is relatively low, the use temperature is -50 degrees, the performance is relatively temperature, the price is cheaper, but it is corrosive. The chlorine-containing solution has a low freezing point, high volatility, and corrosiveness. The applicable temperature range is -50 to -100°C. Water has a large specific heat, low density, low price and easy availability. It is suitable for occasions where the refrigeration temperature is above 0°C. The salt water can lower the freezing point temperature and expand the cooling range. It is suitable for medium and low temperature refrigeration systems.

3. Points for attention when using the laboratory glycol chiller:

A. Before use, you need to check to see if the location of the device is correct to avoid problems during use.

B. When using the laboratory glycol chiller, follow the operating instructions for operation, including turning on and off the machine.

C. Pay attention to good maintenance work, and perform regular maintenance regularly.

D. When the laboratory glycol chiller fails during use, it should be solved in time. Some common failures have information in the instruction manual, which can't be solved. Contact the manufacturer to solve it.

Summarize

Laboratory glycol chillers are used in many industries such as chemicals, new energy, components, industries, etc., and you need to pay attention to the quality of choice when choosing. Global consulting sales@cnzlj.com.

Related News
Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • LT -45℃~30℃

    LT -45℃~30℃

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • IC Test Temperature System      -45℃~250℃

    IC Test Temperature System -45℃~250℃

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • Flash EMMC Temperature Test  -85℃~200℃

    Flash EMMC Temperature Test -85℃~200℃

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat