Wuxi Guanya Refrigeration Technology co., ltd

Energy-efficient high and low temperature circulation box description

With the efficient development of the pharmaceutical and chemical industry, environmental pollution is also the subject of more attention. To this end, LNEYA actively responds to environmental protection, produces energy-efficient and high-temperature circulating boxes, and saves enterprise costs as much as possible.

The high and low temperature circulation box group reduces the condensation temperature under the premise of evaporation temperature. In order to meet the safety and production requirements of the equipment, the evaporation temperature is lowered to reduce the condensation temperature, so as to ensure the cooling water efficiency and increase the transformation. Adjust the reasonable operation of the chiller equipment. When the equipment is safely operated, the cooling unit operates at 70%-80% load ratio and runs at 100% load, and the power consumption per unit of cooling capacity is smaller. In this way, it is necessary to combine the operation of the water pump and the cooling tower.

Prevent and reduce pipe fouling to improve the heat exchange efficiency of the condenser and evaporator. Replenish water If the water treatment is not good, calcium carbonate and magnesium carbonate produced by the heating of calcium bicarbonate and magnesium bicarbonate will deposit on the pipeline. Decreasing the thermal conductivity, affecting the heat exchange efficiency of the condenser and the evaporator, and greatly increasing the electricity cost of the equipment. In addition to the water treatment technology, it is also possible to use the pipeline automatic cleaning equipment for pipeline cleaning. The high-low temperature cycle box group refrigerator frequency conversion device adjusts the speed of the centrifugal refrigerator compressor. After the low-pressure refrigerant passes through the centrifuge, the pressure rises. The higher the speed of the centrifuge, the higher the pressure rises. In actual operation, most of the equipment is running at a non-full load. A fixed-speed centrifuge wastes energy when the equipment is running at a small load. The variable frequency centrifugal chiller can automatically adjust the compressor speed according to the change of the load, and the energy saving space is relatively large.

These operating instructions can help the high and low temperature circulation box to be more energy efficient and use as much energy consumption as possible.
Related News
Related Products
  • Water Cooled Chiller

    Water Cooled Chiller

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temperature Test Chamber

    High-Low Temperature Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • Humidity Test Chamber

    Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Small Gas Condensing System

    Small Gas Condensing System

    April 10, 2018ModelHQ-0540HQ-1040HQ-2540HQ-5040HQ-0575WHQ-1075WHQ-2575WHQ-5075WGas flow5m3/h10m3/h25m3/h50m3/h5m3/h10m3/h25m3/h50m3/hLowest Temp.-40℃-40℃-40℃-40℃-75℃-75℃-75℃-75℃Primary Temp.There is no-20℃...view
products
Contact
Tel: + 86 18751547965
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat