How to solve the phenomenon of ultra-low temperature freezer card cylinder?

If the ultra-low temperature freezer room fails during operation, it needs to be solved in time. If it is similar to the related phenomenon, it may be that the frozen oil does not come up, and the operator needs to solve it in time.

Ultra-low temperature freezer compressor compressor card cylinder processing method is more, increasing the capacitance is one of the common methods, simply speaking, the original capacitor and a capacitor or a large point of capacitance to increase the starting torque to make the compressor easier Run it up, pay attention: the compressor will shut down immediately after two or three seconds.

Ultra-low temperature freezer compressor card cylinder tapping method, generally choose wooden hammer or select available objects in place. The hammer hits the three solder joints on the body when the press is started. But pay attention, you can't knock deformation. Gently tap the compressor casing to slightly loosen the stuck part, sometimes start the operation or increase the power supply voltage by 10%, and start the impact multiple times. This method can solve the problem of insufficient lubrication of the card cylinder. The compressor of the chiller is particularly effective. The ultra-low temperature freezer compressor card cylinder can also adopt the strong lifting method, connect a plug, L is directly connected to the C terminal, N is connected to the M terminal, and the other is connected to the branch line N1. The power is turned on to let the N1 touch the starting end of the compressor. .

The pneumatic shock method can be used to separate the compressor separately, and the compressor is supplied with a reaction force of 0.1 MPA from the high pressure pipe. The loose shaft mechanism is loosened. Rinse for 5 minutes. Then use the above method. Usually, there is a scale inside the compressor, or a card cylinder caused by dirty things. The above does not work. The compressor is removed and the oil is poured out. Add kerosene, then pour it out, once in a row, the purpose is to clean the dirty things inside. After washing, put the compressor upside down for 12 hours, pour the kerosene and volatilize it. Then add the frozen oil, pick up the compressor and then a few times on the ground to loosen the parts. Then use the above method to start.

Regardless of the failure of the ultra-low temperature freezer, the user needs to solve the problem in a timely and effective manner. If another unknown fault occurs, contact the manufacturer's technical personnel for resolution.


Related News
Related Products
  • Water Cooled Chiller SLJ

    Water Cooled Chiller SLJ

    January 11, 2018Temperature ranges from - 5 ~ - 150 degrees, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temperature Test Chamber

    High-Low Temperature Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • Humidity Test Chamber

    Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
  • Single Fluid Heat Transfer TCU SR

    Single Fluid Heat Transfer TCU SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Material TCU ZLF

    Reactor Material TCU ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Small Gas Condensing System

    Small Gas Condensing System

    April 10, 2018ModelHQ-0540HQ-1040HQ-2540HQ-5040HQ-0575WHQ-1075WHQ-2575WHQ-5075WGas flow5m3/h10m3/h25m3/h50m3/h5m3/h10m3/h25m3/h50m3/hLowest Temp.-40℃-40℃-40℃-40℃-75℃-75℃-75℃-75℃Primary Temp.There is no-20℃...view
products
Contact
Tel: + 86 13912479193
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat