Wuxi Guanya Refrigeration Technology co., ltd
products
Contact
Tel: + 86 510 82303782
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province,China
code chat

-80 °C refrigerator manufacturer operating equipment points

When the user chooses the -80 °C refrigerator, it is definitely necessary to have a reliable quality. Wuxi Guanya (LNEYA)-80 °C refrigerator should pay attention to its operation details during operation to avoid equipment failure caused by improper operation.

The following items should be mastered during use. Please check if the -80 °C refrigerator is damaged during installation, and choose the right place for installation and future maintenance. The site where the unit is installed must be the floor, mounting mat or foundation with a level of 6.4 mm and can withstand the operating weight of the unit. - It should be placed in a machine room with a room temperature of 4.4-43.3 °C. There should be enough space around and above the unit for routine maintenance work. A pipe space for cleaning the condenser tube bundle should be left at one end of the device, or a door hole or other suitable hole can be used.

Select the water pipe of the appropriate pipe diameter, the cooling system and the cold water system of the -80 °C refrigerator unit during high power operation, and connect them correctly. For normal applications, the water flow rate through the evaporator and condenser is between 1.0 and 3.6 m/s.

Under any load, the water flow rate should be stable. All chilled water and cooling water pipes should be designed and installed according to the conventional method. The chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow in the unit. The piping should be provided with a damping tube to ensure proper flexibility and to prevent the evaporator water from being drained when the pump is shut down. The piping should have a solid support independent of the -80 °C refrigeration unit to prevent stress from being applied to the refrigeration unit components. The hangers are set up to facilitate pipe alignment.

-80 °C refrigerator manufacturers will provide corresponding instructions when the equipment is shipped from the factory, users need to read and operate carefully when using.
Related News
Related Products
  • Ultra-Low Temperature Cooled Chiller -150℃

    Ultra-Low Temperature Cooled Chiller -150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 degrees, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temperature Test Chamber

    High-Low Temperature Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • Humidity Test Chamber

    Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
  • Single fluid heat transfer temperature control system SR TCU

    Single fluid heat transfer temperature control system SR TCU

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor material temperature control system ZLF TCU

    Reactor material temperature control system ZLF TCU

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Small Gas Condensing System

    Small Gas Condensing System

    April 10, 2018ModelHQ-0540HQ-1040HQ-2540HQ-5040HQ-0575WHQ-1075WHQ-2575WHQ-5075WGas flow5m3/h10m3/h25m3/h50m3/h5m3/h10m3/h25m3/h50m3/hLowest Temp.-40℃-40℃-40℃-40℃-75℃-75℃-75℃-75℃Primary Temp.There is no-20℃...view
  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province,China