Wuxi Guanya Refrigeration Technology co., ltd
Description of PID control algorithm reaction kettle temperature control system

Description of PID control algorithm reaction kettle temperature control system

Application: Various Reactors, Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Biological and Other Industries.



  • Product Description
The fuzzy PID control algorithm temperature control system of the reaction kettle is a temperature control equipment that meets the requirements of some temperature sections in the laboratory. It is often needed in various reaction processes in laboratories of various industries such as industry. Well, do you all know some characteristics of the equipment? What are there?


1. Check and measure the power supply voltage of the system to see if there is undervoltage or phase loss; Whether the motor vent of the pump is blocked, which will affect the heat dissipation of the motor and cause excessive current; Whether the pipeline valves are unblocked and whether the system is under high pressure; Whether the thermal setting value of the thermal overload relay is low.

2. Abnormal power on automatic detection system: abnormal phase sequence of three-phase power supply, abnormal liquid level of expansion tank, abnormal state of emergency stop switch, abnormal pump operation and abnormal system over temperature;

3. Data reading: system outlet temperature data reading, system inlet temperature data reading, system heating pipe temperature data reading;

4. It can meet the requirements of remote control function: support system remote start, stop, alarm reset, support system heating power setting, support system temperature setting, support real-time temperature feedback, support fault signal feedback, support system operation signal feedback;

5. It can also meet the customer's equipment maintenance needs: it supports the system use time accumulation function, the system operation time accumulation function, the resettable time, the system filter time accumulation function, the resettable time, the system contactor time accumulation function, the resettable time, the system oil tank level rod time accumulation function, the resettable time, the system heating pipe time accumulation function, the resettable time Support the system pump time accumulation function, and reset the time;

6. PLC control + touch screen display operation mode is adopted.

Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview