-20 ° C freezer manufacturers choose what to look at the evaporator?

In the process of producing industrial freezer, the selection of a suitable evaporator is also very important for the freezer, because the choice of suitable evaporator is better for better operation of the -20 °C freezer.

The evaporator is generally equipped with a -20 °C freezer, and the user does not have to choose. However, in order to better maintain the refrigeration system and ensure its efficient operation, some factors should be noted. Due to the influence of the height of the refrigerant liquid column of the -20 °C freezer manufacturer, the evaporation temperature at the bottom of the full liquid evaporator is higher than the evaporation temperature of the liquid surface. Different refrigerants have different effects on the evaporating temperature of different liquid levels due to the height of the hydrostatic fluid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the effect of the hydrostatic height on the evaporation temperature. Therefore, the effect of the hydrostatic height on the evaporation temperature can be ignored only when the evaporation pressure is high. When the evaporation temperature is low, it cannot be ignored. That is to say, it is uneconomical to use a full liquid evaporator at this time.

If the -20 ° C freezer evaporating temperature is lower than the brine solidification temperature, the brine may freeze. In one process of the brine, the temperature of the brine is low and the possibility of freezing is relatively large. When water is used as the brine, it is theoretically possible that the inner wall temperature of the tube can be as low as 0 °C. However, for safety reasons, the inner wall temperature of the tube at the outlet end of a process is usually maintained above 0.5 °C. In the case of brine as a coolant, according to the same principle, the inner wall temperature of the pipe should be higher than the solidification temperature of the brine by more than 1 °C.

When the -20 °C freezer refrigerant flows through the evaporator, the pressure loss is caused, and the pressure p2 of the refrigerant at the outlet of the evaporator is inevitably lower than the pressure p1 at the inlet, thereby lowering the suction pressure of the compressor, resulting in a decrease in the refrigeration capacity. According to different models, the choice of evaporator is different, such as box type freezer, using water tank coil evaporator; open type freezer and screw type freezer, use shell and tube evaporator; Acid-base freezer, you can choose titanium tube evaporator or stainless steel plate exchanger, of course, can be customized according to user needs.

In general, manufacturers have certain principles in selecting evaporators. Basically, brand evaporators are one of the manufacturers' choices.

Related News
Related Products
  • Direct-Cooled Ultra-Low Temperature Chiller -150℃

    Direct-Cooled Ultra-Low Temperature Chiller -150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 degrees, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temp. Test Chamber

    High-Low Temp. Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • High-Low Temp. Humidity Test Chamber

    High-Low Temp. Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
  • Single fluid heat transfer temperature control system SR TCU

    Single fluid heat transfer temperature control system SR TCU

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor material temperature control system ZLF TCU

    Reactor material temperature control system ZLF TCU

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Small Gas Condensing System

    Small Gas Condensing System

    April 10, 2018ModelHQ-0540HQ-1040HQ-2540HQ-5040HQ-0575WHQ-1075WHQ-2575WHQ-5075WGas flow5m3/h10m3/h25m3/h50m3/h5m3/h10m3/h25m3/h50m3/hLowest Temp.-40℃-40℃-40℃-40℃-75℃-75℃-75℃-75℃Primary Temp.There is no-20℃...view
  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province,China