Closed Refrigeration Heating Circulator Daily Maintenance Manual

The closed refrigeration and heating circulators of different manufacturers have a certain life span. Reasonable and correct operation and maintenance of the closed refrigeration heating circulator can effectively extend the service life.

The user regularly maintains the closed refrigeration heating circulator, promptly eliminates the instrument failure, and makes maintenance records. The large equipment is cleaned and maintained 2-4 times per semester. The damaged closed refrigeration heating circulator should be overhauled by the equipment manufacturer's professional. If external repair is required, the application should be submitted to the equipment. Equipment management personnel should strive to learn business and improve the level of management, maintenance and maintenance. Conduct regular inspections according to the specifications specified by the instrument or the performance indicators during commissioning, and register for future reference.

When the closed refrigeration heating circulator is turned on, it should be seen whether the steering of the fan is accurate. If the forward rotation can be started, the reverse rotation indicates that the power supply wiring is reversed, and the phase sequence must be replaced before starting. The setting values of each protection device are high and low temperature cycle. The factory has been set up, and users should not change it at will.

When the closed cooling and heating circulator is stopped, press the stop button to check the cause of the high fault. Do not force the machine to run before the fault is eliminated. If you use it for a long time in the winter, turn off the main power and drain the water in the system. It is necessary to keep the machine room clean and ventilated well, and carry out the cleaning and removing work of the condenser on schedule to ensure that the refrigeration and heating integrated machine does not work normally.

When using a closed refrigeration heating circulator, it is also necessary to pay attention to the selection of materials made of materials that are resistant to high temperature and corrosion resistant processes. In general, when using a closed refrigeration heating circulator, the temperature is in the range of 100 ° C - 300 ° C, the heating temperature is different, the oil used is also different, glycerin, paraffin oil, silicone oil, vacuum pump oil or some vegetable oil Yes, you can choose the right oil based on their heating temperature.

Closed refrigeration heating circulators provide corresponding cold sources in the pharmaceutical, chemical, biological and other industries. As a constant temperature source, the performance requirements are self-evident, so we must pay attention to the necessary maintenance.


Related News
Related Products
  • Water Cooled Chiller

    Water Cooled Chiller

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Low Temperature Chiller

    Low Temperature Chiller

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • Wafer Test Chiller

    Wafer Test Chiller

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • Chip Test Heating Cooling System

    Chip Test Heating Cooling System

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact
Tel: + 86 13358153746
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat