Search the whole station

Single Fluid Heat Transfer System SR
Single Fluid Heat Transfer System SR
Single Fluid Heat Transfer System SR
Single Fluid Heat Transfer System SR

SR -120℃~250℃ Multi reactor chiller

Can temperature control reaction material
  • Heating Power25kW~80kW
  • Power range2.3kW~10.5kW
  • Material accuracy±1℃
  • Power with”H”27.3kW~90.5kW
  • Heat exchange area3.5㎡~20㎡

Product data download

Product Description



TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infrastructure are integrated into the single fluid system was used to control the temperature of process equipment or in the secondary loop.This achieves only one type of heat transfer liquid can flow into the jacket of the reaction vessel (not directly flow into steam, cooling water or ultra-low temperature liquid).The temperature of the whole reaction process is controlled by operation.

Excellent performance, high precision, intelligent temperature control, very wide temperature control range, from -120 °C ~ 350 °C, suitable for most enterprises temperature control needs. Product temperature control accuracy of ± 0.5 ° C, cooling power from 0.5 kW to 1200 kW can provide the corresponding products.

Temperature Process Control Principle (Control Reaction Kettle Material Temperature)


Model SR-35N
SR-35NS
SR-35NH
SR-35NSH
SR-50N
SR-50NS
SR-50NH
SR-50NSH
SR-80N
SR-80NS
SR-80NH
SR-80NSH
SR-125N
SR-125NS
SR-125NH
SR-125NSH
SR-200N
SR-200NS
SR-200NH
SR-200NSH
Temp. range ℃ -120~ 250degree setting the max temp according to the supplier heating or cooling source)
-40~135degree(The maximum temperature range can be operated by using glycol water formula.)
SR-N A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank.
SR-NS Besides SR- N function,add one set heater used to reduce high temp.
SR-NH Besides SR- N  function,add electrical heating function
SR-NSH Besides SR- N  function,add one set heater used to reduce high temp and electrical heating function
Expansion tank 100L 200L 280L 390L 500L
Heat exchanger area 3.5m2 5m2 8m2 12.5m2 20m2
Electric heating function H 25KW 35KW 50KW 65KW 80KW
With “H” has heating function
Control mode Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
Communication protocol MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
Temperature control selection Material control temp
Temperature feedback The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
Material temp. feedback:PT100 or 4~20mA or communication given
Temp.feedback:PT100
Process temp. feedback
feedback:PT100
Temperature accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
Circulation pump 200L/min 2.5BAR 250L/min 2.5BAR 400L/min 2.5BAR 500L/min 2.5BAR 750L/min 2.5BAR
Input and display 7-inch color touch screen,temperature graph display
Safety protection Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
Perform valve Electric proportional control valve, control signal 4~20mA.
Piping material SUS304
Connection size DN40 DN40 DN-50 DN-65 DN-80
Dimension mm 1500*1200*1850 1800*1400*2400 1500*1500*2050 1800*1400*2400 2200*1800*2650
Power
AC380V50HZ
2.3kw(max) 3.5kw(max) 4.5kw(max) 8kw(max) 10.5kw(max)
With H power
AC380V 50HZ
27.3kw(max) 38.5kw(max) 54.5kw(max) 73kw(max) 90.5kw(max)
Case material SUS 304 SUS 304 SUS 304 SUS 304 SUS304
Click online message to inquire about product details
Send us a message about TCU-SR
Send us a message about TCU-SR
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

Expand more!