1.Dust and corrosive gases in the working environment of the low temperature chamber can also affect the flexibility of the mechanical system and reduce the reliability of various limit switches, keys and photoelectric couplers. This is also one of the causes of corrosion of aluminium film.

2.The temperature and humidity of the low temperature chamber are the important factors affecting the performance of the instrument. It can cause the corrosion of mechanical parts, reduce the smoothness of metal mirror, and cause the error or performance degradation of mechanical parts of high and low temperature test box. The corrosion of optical components such as gratings, mirrors and focusing mirrors in high and low temperature test boxes results in insufficient light energy, stray light, noise, etc. Even the instruments stop working, thus affecting the life of high and low temperature test boxes, which should be regularly corrected during maintenance.

3. A certain amount of dust will accumulate inside the low temperature chamber after a certain period of use. It is better for the cryogenic testing machine to open the outer cover of the high and low temperature testing box periodically under the guidance of the maintenance engineer or engineer for dust removal. At the same time, the radiators of each heating element are re-tightened to clean the sealing window of the optical box. If necessary, it should be calibrated to clean and lubricate the mechanical part. Finally, it should be restored to its original state and some necessary tests, adjustments and records should be made.
Related News
Related Products
  • Water Cooled Chiller

    Water Cooled Chiller

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Low Temperature Chiller

    Low Temperature Chiller

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • Wafer Test Chiller

    Wafer Test Chiller

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • Chip Test Heating Cooling System

    Chip Test Heating Cooling System

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact
Tel: + 86 13358153746
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat