Wuxi Guanya Refrigeration Technology co., ltd

Low Temp Circulator Of Wuxi Guanya Has More Than 10 Years Of Exploration And Innovation, Precipitati

Wuxi Guanya Refrigeration technology co., ltd is a professional manufacturer of refrigeration equipment in China. It is a production technology-oriented enterprise integrating R&D, production, sales and after-sales. It specializes in the production of all kinds of low temp circulator, refrigerators, high and low temperature machine standards and non-standard products.

The low temp circulator is a new product designed and manufactured by Wuxi Guanya Refrigeration technology co., ltd with many years of experience in refrigeration, heating and temperature control. It integrates advanced technology of similar products at home and abroad with practical application.

The low temp circulator adopts imported brand semi-enclosed piston compressor, semi-enclosed piston two-stage compressor and semi-enclosed screw compressor, and the evaporator adopts high-power plate heat exchanger. It has small size and high efficiency. It adopts a complete set of imported cold control units (DANFOSS pressure controller, balance valve, expansion valve, solenoid valve, drying filter, Emerson oil separator, ALCO liquid mirror, one-way valve, etc.). The cooling water loop of the unit adopts intermediate heat exchanger, which significantly improves the reliability and safety of the system. It uses DANFOSS electronic expansion valve with high control precision. It uses Siemens PLCS7-200/300 PLC and LNEYA touch screen display for automatic control operation. It has temperature curve display, temperature record U disk, fault alarm record. The large refrigeration unit adopts semi-closed screw compressor with economizer and it combines with electronic expansion valve for control to ensure high efficiency and energy saving.

Wuxi Guanya Refrigeration technology co., ltd is self-disciplined. We are committed to the production and development of low temp circulator more stable and efficient cryogenic cycle with the installation of the whole machine. The system has been tested in the factory. Users only need to install refrigerant pipeline and cooling water pipeline to run.

The factory tests each refrigeration unit in the factory. Load test not less than 12 hours. In addition, Wuxi Guanya Refrigeration technology co., ltd continuously improves the quality of after-sales service to provide faster and more intimate service. It allows customers to use it conveniently and satisfactorily with a guarantee of confidence in choice.

We are grateful to friends from all walks of life for their love of our company and sincere cooperation with us. We hope that our friendship will advance with each passing day in honesty and frank cooperation. Our company wholeheartedly welcomes new and old friends from all walks of life to visit us, exchange and negotiate with us, seek common development, and create a better tomorrow hand in hand.
Related News
  • LNEYA Is Exhibiting At Achema 2018

    LNEYA Is Exhibiting At Achema 2018

    January 11, 2018​The LNEYA Group will participate in the ACHEMA -World Forum and Leading Show for the Process Industries,Frankfurt am Main, Germany.view
  • Approaching LNEYA 5 Main Products

    Approaching LNEYA 5 Main Products

    January 11, 2018Industrial Chiller:Industrial Chiller varies from dynamic temp. Special Chiller:Special Chiller consist of Multi-reactor chiller (TCU).Environmental Chamber:The test object is connected to a testing adapter. Industrial Freezer:Industrial freezer consist oview
  • The Analysis Of Ultra Low Freezer'S Price

    The Analysis Of Ultra Low Freezer'S Price

    July 4, 2018What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the proce...view
  • The Application of Cold Plate Freezer

    The Application of Cold Plate Freezer

    July 4, 2018The refrigeration system of cold plate freezer adopts secondary super-cooler technology with the rapid refrigeration and low limiting temperature. It uses imported brand name semi-hermetic piston comp...view
  • 2018 Automotive Testing Expo

    2018 Automotive Testing Expo

    September 11, 2018Automotive Testing Expo 9.25-9.27view
  • The Analysis Of How To Maintain The Low Temperature Circulator In Daily Life

    The Analysis Of How To Maintain The Low Temperature Circulator In Daily Life

    July 4, 2018Guanya is a leading role in heating cooling circulator. It provides the customers with proposal and technology of controlling the cold and heat, temperature control system with stable property, extend...view
Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • LT -45℃~30℃

    LT -45℃~30℃

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • TES -45℃~250℃

    TES -45℃~250℃

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • TES -85℃~200℃

    TES -85℃~200℃

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat