{"id":13894,"date":"2025-05-28T13:45:19","date_gmt":"2025-05-28T05:45:19","guid":{"rendered":"https:\/\/www.lneya.com\/?p=13894"},"modified":"2025-05-28T13:45:21","modified_gmt":"2025-05-28T05:45:21","slug":"why-is-temperature-cycling-testing-performed-on-chips","status":"publish","type":"post","link":"https:\/\/www.lneya.com\/it\/blog\/why-is-temperature-cycling-testing-performed-on-chips.html","title":{"rendered":"Why Is Temperature Cycling Testing Performed On Chips?"},"content":{"rendered":"

Why Is Temperature Cycling Testing Performed On Chips?<\/p>\n\n\n\n

<\/p>\n\n\n\n

Temperature cycling testing is a technique employed to evaluate the durability of semiconductor chips. By repeatedly exposing the chip to alternating high and low temperatures, this test simulates how the chip performs under extreme thermal conditions. After reading this blog post, you\u2019ll gain a solid understanding of what temperature cycling testing is, why it matters, how it\u2019s conducted, and the relevant testing standards.<\/p>\n\n\n\n

<\/p>\n\n\n\n

What Is The Temperature Cycling Testing?<\/h1>\n\n\n\n

<\/p>\n\n\n\n

Temperature cycling testing<\/a> is performed during both the product development and screening phases. It is also called thermal cycle test or high-low temperature cycling test. During the test, the sample is exposed to a controlled environment where high and low temperatures alternate in cycles. This process is used to evaluate the product\u2019s durability and reliability under thermal stress.<\/p>\n\n\n\n

<\/p>\n\n\n\n

<\/p>\n\n\n\n

How To Perform Temperature Cycling Testing?<\/h1>\n\n\n\n

<\/p>\n\n\n\n

Temperature Cycling Testing Procedure<\/h2>\n\n\n\n

<\/p>\n\n\n\n

Step 1: Place the chip to be tested into the temperature cycling test chamber<\/strong>.<\/p>\n\n\n\n

Step 2: Set the high and low temperature range. Typically, the high temperature ranges from +50\u00b0C to +150\u00b0C, while the low temperature ranges from -10\u00b0C to -70\u00b0C. These settings can be adjusted based on specific testing requirements.<\/p>\n\n\n\n

Step 3: Within the defined temperature range, the test chamber continuously cycles the temperature. For example, the chip may be exposed to high temperature for 12 hours, then to low temperature for another 12 hours, repeating this cycle.<\/p>\n\n\n\n

Step 4: Repeat the temperature cycling process until the chip reaches the predetermined number of cycles or fails due to thermal stress.<\/p>\n\n\n\n

<\/p>\n\n\n\n

Technical Parameters of Temperature Cycling Testing<\/h2>\n\n\n\n

<\/p>\n\n\n\n

The technical parameters of temperature cycling testing include: high temperature, high-temperature dwell time, cooling rate, low temperature, low-temperature dwell time, heating rate, and the number of cycles. The severity of the test depends on the high\/low temperature range, humidity levels, and exposure duration.<\/h2>\n\n\n\n

<\/p>\n\n\n\n

According to available data, a minimum of three cycles is required for temperature stabilization. This means that chip-level temperature cycling tests must be conducted at least three times. While stability is typically achieved after three cycles, for better repeatability, it is recommended to perform at least two additional cycles\u2014for a total of five.<\/p>\n\n\n\n

<\/p>\n\n\n\n

When conducting temperature cycling testing, the number of cycles should be selected based on the product\u2019s actual operating environment and reliability requirements. This ensures the results accurately reflect the product\u2019s real-world performance under thermal stress.<\/p>\n\n\n\n

<\/p>\n\n\n

\n
\"\"
Semiconductor packaging and testing process, chip temperature cycle test helps to improve stability during use.<\/figcaption><\/figure><\/div>\n\n\n

<\/p>\n\n\n\n

Standards of Temperature Cycling Testing<\/h2>\n\n\n\n

<\/p>\n\n\n\n