
Servizio globale
30.000 + clienti.
20+ paesi.

Brevetti di certificazione
CE, SGS, certificazione ISO.

Servizio post-vendita
24/7 solutions.

Team di professionisti
Oltre 15 anni di esperienza.

Controllo qualità
Test di qualità.
Ricerca nell'intera stazione
SUNDIZ-45℃~250℃ thermal control unit includes cooling system, heating system, control system, circulation system, etc.
LNEYA thermal control unit heats and cools to keep the process temperature within range. It handles high heat and adapts cooling and heating to your needs. The SUNDIZ process chiller runs from -45℃ to 250℃, switches between hot and cold, and cools quickly even at high temperatures. It offers ±0.1℃ medium control and ±0.3℃ process control, ideal for pharma, chemical, semiconductor, new energy, and aerospace.
Modello | SUNDIZ4-3 SUNDIZ4-3W | SUNDIZ4-5 SUNDIZ4-5W | SUNDIZ4-10 SUNDIZ4-10W | SUNDIZ4-15W | SUNDIZ4-20W | SUNDIZ4-30W | |
Intervallo di temperatura | -45℃~250℃ | ||||||
Potenza di riscaldamento | 5,5kW | 7,5kW | 15kW | 25kW | 38kW | 60kW | |
Cooling capacity kW | 250℃ | 5,5kW | 7,5kW | 15kW | 25 kW | 38kW | 60kW |
20℃ | 5,5kW | 7,5kW | 15 kW | 25kW | 38kW | 60kW | |
-15℃ | 2.3kW | 3.6kW | 7.5 kW | 11kW | 15kW | 33kW | |
-35℃ | 0,9kW | 1,5kW | 3.3 kW | 5kW | 6,5kW | 10kW | |
Medium temp control accuracy | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Process temp control accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
Pump flow rate pressure max | 50L/min | 50L/min | 100L/min | 150L/min | 250L/min | 400L/min | |
2bar | 2bar | 2bar | 2,5 bar | 2,5 bar | 2,5 bar |
VFD energy-saving
SUNDIZ -45℃~250℃ chiller heater unit uses VFD, which can automatically control the output flow and pressure according to the actual cooling and heating needs, reduce power consumption, and save more than 20% energy compared to fixed frequency bandwidth.
Fully enclosed
The SUNDIZ-45℃~250℃ thermal control unit adopts a fully enclosed pipeline design. The heat transfer medium in the expansion container does not participate in the circulation. The expansion tank temperature is maintained at a room temperature of 60℃, which effectively reduces the risk of the heat transfer medium absorbing moisture and volatilizing during the operation of the chiller.
anodizing and electroplating
The thermal control unit is often used to control the temperature of the plating solution and the oxidation tank, thereby improving the treatment quality of the metal surface.
casting process
It is used to control the temperature of the molten metal to prevent thermal stress from causing product defects.
chemical reactions
It is used to control the temperature of reactors and distillation equipment to improve the stability and yield of chemical reactions.
SUNDI -10℃~+150℃
unità di raffreddamento e riscaldamento
SUNDI -25℃~+200℃
circolatore di refrigerazione e riscaldamento
SUNDI -45℃~+250℃
riscaldamento refrigeratore
SUNDI -60℃~+250℃
scaldabagno e refrigeratore
30.000 + clienti.
20+ paesi.
CE, SGS, certificazione ISO.
24/7 solutions.
Oltre 15 anni di esperienza.
Test di qualità.
TEL:TELEMATICO
EMAIL: EMAIL: EMAIL: EMAIL: EMAIL: EMAIL: EMAIL
WeChat e WhatsApp: il nostro servizio
Hai domande o hai bisogno di un preventivo? Compila il modulo sottostante e il nostro team ti risponderà entro 24 ore.