Several Common Troubleshooting Methods for Ultra-low Temperature Freezer in Laboratories
Although the refrigeration system and control circuit of ultra low temperature freezer in laboratory are complex, the common faults are mainly circulating system and circuit part.
Following are several common faults of ultra-low temperature refrigerators and their troubleshooting methods:
1. After power supply is switched on, the air switch of the main power supply is automatically disconnected.
Elimination method: Check whether the compressor of refrigeration system is damaged or not, and replace the parts if damaged. After replacing the fittings, turn on the machine to check whether it is normal. The fault is usually caused by unstable power supply, because the * stage starts first, so the damage is usually in stage. In this case, as long as the delay regulated power supply is installed, the fault will not occur again.
2. Stop working before the temperature in the box reaches the set temperature.
Exclusion: Although the temperature in the box has not reached the set temperature, the panel display temperature has reached the set temperature. This is due to the damage of the thermistor which detects the temperature and the need to replace the parts. If there is no original accessories, a set of temperature control system can be re-installed to eliminate the failure.
3. Poor refrigeration effect may be refrigerant leakage
4. If the ultra-low temperature refrigerator does not start in winter, it may be that the thermostat regulation value is too small.
We are a ultra low temperature freezer manufacturer. Welcome to choose our products.
Raccomandazioni correlate
-
quali sono le cause dell'intasamento del refrigeratore
935Il raffreddatore è una parte molto importante del compressore d'aria a vite. La funzione principale è quella di raffreddare l'olio lubrificante del compressore d'aria e l'aria compressa. Se è bloccato, la temperatura aumenta. Una delle principali cause di guasto del compressore d'aria...
Visualizza i dettagli -
Why is it dangerous to use an enamel reactor?
1201The enamel layer of the enamel reaction kettle is easy to burst when it is cold and hot. Because the enamel layer is sintered on the surface of the enamel reaction kettle, and the enamel layer will melt when it exceeds 200 degrees Celsius, so the...
Visualizza i dettagli -
Way to Check Problems of the Lubricating Oil System of the Screw Chiller Factory
951Everyone pays more attention to the refrigerant circulation system and the chilled water circulation system of the screw chiller factory operation system. However, lubricating system is often neglected by everyone. In fact, this system of cold wat...
Visualizza i dettagli -
Il ruolo del sistema di controllo della temperatura TCU nel reattore chimico e farmaceutico
1268Il controllo della temperatura del bollitore di reazione nella ricerca e sviluppo di farmaci e negli esperimenti chimici, così come il controllo della temperatura nella produzione sperimentale su piccola scala e nei processi di produzione industriale, richiedono una tempera...
Visualizza i dettagli