-80 °C refrigerator manufacturer operating equipment points
When the user chooses the -80 °C refrigerator, it is definitely necessary to have a reliable quality. Wuxi Guanya (LNEYA)-80 °C refrigerator should pay attention to its operation details during operation to avoid equipment failure caused by improper operation.
The following items should be mastered during use. Please check if the -80 °C refrigerator is damaged during installation, and choose the right place for installation and future maintenance. The site where the unit is installed must be the floor, mounting mat or foundation with a level of 6.4 mm and can withstand the operating weight of the unit. – It should be placed in a machine room with a room temperature of 4.4-43.3 °C. There should be enough space around and above the unit for routine maintenance work. A pipe space for cleaning the condenser tube bundle should be left at one end of the device, or a door hole or other suitable hole can be used.
Select the water pipe of the appropriate pipe diameter, the cooling system and the cold water system of the -80 °C refrigerator unit during high power operation, and connect them correctly. For normal applications, the water flow rate through the evaporator and condenser is between 1.0 and 3.6 m/s.
Under any load, the water flow rate should be stable. All chilled water and cooling water pipes should be designed and installed according to the conventional method. The chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow in the unit. The piping should be provided with a damping tube to ensure proper flexibility and to prevent the evaporator water from being drained when the pump is shut down. The piping should have a solid support independent of the -80 °C refrigeration unit to prevent stress from being applied to the refrigeration unit components. The hangers are set up to facilitate pipe alignment.
-80 °C refrigerator manufacturers will provide corresponding instructions when the equipment is shipped from the factory, users need to read and operate carefully when using.

Raccomandazioni correlate
-
Sistema di riscaldamento di raffreddamento del reattore per la fabbrica farmaceutica
9671.Process requirements: 2.Media compatibility: 3.Temperature range: 4.Cleanliness requirements: 5.Space and maintenance: In summary, t...
Visualizza i dettagli -
Why do constant temperature and humidity chamber need water cooling units?
848Constant temperature and humidity chamber need water cooling units mainly for the following key reasons: Accurate temperature and humidity control: Water cooling units can provide efficient and accurate temperature regulation capabilit...
Visualizza i dettagli -
Air-cooled and water-cooled methods of cooling and heating circulators
1077The cooling heating circulator is controlled by high and low temperature during operation. After the user runs at high temperature and low temperature, it can be heated with heat transfer oil, which is water-cooled and air-cooled. 1. It belongs ...
Visualizza i dettagli -
Frigorifero antideflagrante: adatto per impianti di produzione meccanica
1432Il frigorifero a prova di esplosione LNEYA è un tipo di frigorifero speciale utilizzato principalmente in ambienti industriali speciali per conservare merci pericolose difficili da conservare, volatili, infiammabili ed esplosive. Con lo sviluppo della benzina...
Visualizza i dettagli