Basic maintenance of high and low temperature refrigeration circulating pumps
Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protection device of the high and low temperature refrigeration cycle pump group will stop and even cause malfunction due to the condensing temperature and the corresponding condensing pressure being too high. The cold water in the evaporator should be circulated, otherwise the cold water temperature will be low, the cold water temperature protection device will stop, or the low temperature protection device will stop due to the evaporation temperature and the corresponding evaporation pressure being too low, even leading to the evaporator. Cold water freezes and damages equipment.

Therefore, the boot sequence is: (must be strictly observed) Cooling tower fan on → cooling water pump on → cold water pump on → high and low temperature refrigeration cycle pump group. The shutdown sequence of the high and low temperature refrigeration circulating pump set is: (must be strictly observed) The equipment group stops → the cooling tower fan stops → the cooling water pump stops → the cold water pump stops. When the machine is shut down, the equipment group should be shut down half an hour before leaving work. The cold water pump is shut down after work, which is conducive to saving energy, avoiding downtime and protecting the unit. Before running the high and low temperature refrigeration cycle pump refrigeration cycle, make sure that the heating cycle pipe valves are all closed.
Maintenance of high and low temperature refrigeration circulating pumps is indispensable. At the same time, the operator needs to have certain operational knowledge of the equipment and will not find operational faults.
Raccomandazioni correlate
-
Low-temperature cycle equipment operation importance description
1038The use of low-temperature cycle equipment is inseparable from its standard operation. LNEYA low-temperature cycle equipment will be shipped with the corresponding instruction manual, and users can know ahead of time when using it. The low tempera...
Visualizza i dettagli -
2018 CIPM China | You have an invitation to the exhibition from LNEYA
1192The 56th (Fall 2018) National Pharmaceutical Machinery and China International Pharmaceutical Machinery Expo will be held from November 5th to November 7th, 2018 at Wuhan International Expo Center. As one of the professional communication platfor...
Visualizza i dettagli -
Festeggiare il Capodanno e dare il benvenuto al nuovo anno
1276When the bells echo in the clear night sky,When the calendar turns to a new page,We are about to usher in a new year.Thanks for this year's harvestLet us have precious experience on our growthThere is always a reward for sweatThis yearWe sh...
Visualizza i dettagli -
Tester lineare a rapida variazione di temperatura Istruzioni per lo svuotamento e il riempimento
1144Prima di avviare il tester lineare a variazione rapida di temperatura, verificare se sono state adottate le misure di protezione necessarie, quali protezione antincendio, protezione, prevenzione delle perdite e altri strumenti. Controllare se l'alimentazione è stata predisposta secondo ...
Visualizza i dettagli