Quali sono gli interventi di manutenzione dei refrigeratori a glicole nel funzionamento quotidiano?
Nel funzionamento quotidiano del refrigeratore di glicole, se non viene effettuata la manutenzione, l'effetto di raffreddamento sarà ridotto. Pertanto, per migliorare l'efficienza operativa, si consiglia di eseguire la necessaria manutenzione quotidiana. Refrigeratore...
Refrigeration system inspection: Generally, after long-term use of ethylene glycol chillers, various problems will inevitably occur. In the event of a failure, the use of each part of the machine should be carefully checked, focusing on the refrigeration system, electrical system, air system and water system to determine whether their functions are normal. We usually examine them by sound and appearance. If there is a problem, it is recommended to replace it in time.
Refrigerant inspection: Regularly check whether the refrigerant of the glycol chiller leaks: It can be determined by referring to the parameters displayed by the high and low pressure meter on the front panel of the main unit. According to the temperature change of the air temperature (winter and summer), the pressure display of the glycol chiller is also different. When the low temperature chiller is working normally, the high pressure shows 11-17kg, and the low pressure shows 3-5kg.
Cooling water system inspection: It is normal to check whether the cooling water system of the ethylene glycol chiller is normal, whether the cooling water tower fan and water spray shaft are in good operation, and whether the water supply in the built-in water tank of the chiller is normal.
System cleaning: Glycol chillers should be cleaned annually after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good cooling effect.
Voltage and current inspection: Regularly check whether the voltage and current of the glycol chiller are stable and whether the compressor is running normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
The above aspects are some of the areas that require routine maintenance. Of course, there are many other details that need your attention.
Raccomandazioni correlate
-
2018 CIPM China | You have an invitation to the exhibition from LNEYA
1192The 56th (Fall 2018) National Pharmaceutical Machinery and China International Pharmaceutical Machinery Expo will be held from November 5th to November 7th, 2018 at Wuhan International Expo Center. As one of the professional communication platfor...
Visualizza i dettagli -
Requisiti di installazione del refrigeratore industriale
966(1) L'alimentazione del chiller è trifase a quattro fili, la linea di alimentazione (R, S, T) è collegata alla linea di alimentazione del fuoco, (N) alla linea dello zero, (G) alla linea di terra,
Visualizza i dettagli -
Description of Type Selection and Classification of 40GW Cryogenic Chillers
1114If different enterprises and different industries have different requirements for Wuxi Guanya 40GW cryogenic chillers, its model selection is also different. So it is better to have a clear understanding of the needs of the selection of 40GW cryog...
Visualizza i dettagli -
Small environmental test chamber compressor should pay attention after maintenance
1072In the centrifugal small-scale environmental test chamber, the suction recovery device is generally an independent system, and if necessary, the pipeline connected to the condenser and the evaporator can be closed for separate maintenance. After r...
Visualizza i dettagli