Design and Test Technology of High Temperature Environmental Chamber Sales
1. Temperature selection
(1) The climatic zones of the region; Whether the product is exposed to the solar radiation environment near the heating device; Surrounding air, solar radiation and ways of heat transfer from heating devices to products; The actual technical state of the product (open or shaded).
(2)Use similar product temperature. Similar products refer to those with similar USES, performance and installation locations, such as upgrading products
2. The conditions of environmental chamber sales
(1) High-temperature storage
Thermostatic storage: after the sample reaches temperature stability (the temperature of internal components, components, modules, components, etc., also reaches stability) in the high-temperature environment, it can be maintained for at least 2 hours, and the longest can be 48 hours. If the storage time is over 48 hours, the temperature stability time will be included.
Cyclic storage: at least 7 cycles (24h for one cycle). If the key material or high temperature sensitive material is affected by high temperature environment, the cycle number should be increased appropriately.
(2) Hot operation in environmental chamber sales
Thermostatic work: after samples reached the stable in high temperature working environment(judgment methods: the differences of the internal heat of samples of the largest feature or key components should be less than 2 ℃ per hour , If the temperature of the internal element (part) cannot be measured, the temperature time shall be determined according to the thermal analysis to ensure that the temperature of the whole sample is stable)keep it at least 2 h, and then let the sample work, and make it on the specified working temperature to achieve stability, began to test the functionality and performance. After the test is completed, the sample will stop working and the air temperature in the box will be adjusted to the standard atmospheric conditions. After reaching the stability under the standard atmospheric conditions, the overall appearance, function and performance will be tested.
3. Temperature monitoring in environmental chambers
When monitoring the test temperature, the position of the temperature sensor should ensure that the influence of thermal diffusion is negligible, and pay attention to avoid the influence of thermal radiation.
Raccomandazioni correlate
-
Invitation Letter | 10.17-19 Nanjing International Expo Center [5G18]
1288Our company will participate in the 81st APIChina China International Pharmaceutical Raw Material Intermediate Packaging Equipment Exhibition held at Nanjing International Expo Center from October 17-19, 2018. At that time, we will exhibit refrige...
Visualizza i dettagli -
Solution to oil spill of reactor cooling and heating circulator
927When we use some reactor cooling and heating circulators, we will find that the system pressure fluctuates up and down as the temperature rises, and the oil tank is overflowing. So what are the reasons for these conditions in the cooling and heat...
Visualizza i dettagli -
Ic test equipment manufacturer test project description
1078Ic test equipment manufacturers need to pay attention to the test process when conducting project testing. Users can make the ic test equipment run more efficiently through detailed understanding. The ic test equipment is responsible for the exclu...
Visualizza i dettagli -
Precautions for the replacement of refrigerating oil in the cooling system of the vehicle charger
1007The cooling system of the on-board charger should pay attention to the condition of the refrigerating oil during the operation. After the compressor is started, carefully observe the changes in the oil temperature and oil pressure. If the oil chan...
Visualizza i dettagli