Conoscenza della manutenzione del dispositivo di circolazione a temperatura costante ad alta e bassa temperatura
Il dispositivo di circolazione a temperatura costante ad alta e bassa temperatura è una delle apparecchiature più comuni nel sistema di controllo della temperatura. Una buona apparecchiatura è inscindibile dalla manutenzione quotidiana. Ma quanto ne sapete di manutenzione? La manutenzione di alta e...
High and low temperature constant temperature circulation device The entire liquid circulation is closed, with an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, but are mechanically connected, regardless of whether the temperature of the liquid circulation is high temperature or low temperature expansion in the container The medium is below 60 degrees.
High and low temperature constant temperature circulation device, no water vapor absorption at low temperature, no oil mist at high temperature, heat transfer oil can have a wide working temperature; mechanical and electronic valves are not used in the whole circulation system. When opening or closing the test object from the box, the article shall not be in contact with the door sealing strip. If the compressor is cooled by air cooling, the condenser fan shall be regularly inspected and the condenser shall be decontaminated and dedusted.

Due to the different cleanliness levels of the high and low temperature constant temperature circulation device, many small particles such as dust will be condensed on the evaporator under the forced air circulation, so we must clean the evaporator regularly. The humidifier fouling easily causes the humidifier to dry and may burn the humidifier, so the water circuit and the humidifier must be cleaned regularly. At the end of each experiment, it is recommended to clean the test chamber with clean water to keep the equipment clean. After the cabinet is cleaned, the cabinet should be dried to keep the cabinet dry. After the completion of each test, the temperature is set near the ambient temperature, and the power is turned off after about 30 minutes of work, and the wall of the working chamber is wiped clean.
LNEYA high and low temperature constant temperature circulation equipment professional manufacturer, producing various types of high and low temperature one machine, can also design and manufacture various non-standard products according to customer needs.
Raccomandazioni correlate
-
Temperature control instructions for stainless steel reactors and glass reactors
1156Reactor is a kind of reaction equipment in industrial production. It generally needs to be refrigerated or heated. Whether the temperature is suitable or not directly affects its reaction effect. Therefore, if conditions permit, it is generally e...
Visualizza i dettagli -
The Structural Characteristics Of Heating Cooling Systems SST-15 SST-20
1011Anyway, Heating Cooling Systems SST-15 SST-20 is a high-performance product with comprehensive functions and simple operation. It will help customers expedite the experiment and save resources so that improve work efficiency.,
Visualizza i dettagli -
Influenza dei fattori di refrigerazione sui refrigeratori industriali antideflagranti chiusi ad alta temperatura
1085Check whether the high and low temperature enclosed explosion-proof industrial chiller is the cause of its own failure. The selection must be accurate. If the model is not in place, the required refrigeration effect will also not be achieved. It i...
Visualizza i dettagli -
Industrial grade heating and cooling system placement attention
1231Industrial-grade heating and cooling system Before the power is turned on, check whether the voltage specified on the nameplate is the same as the household voltage. The same can be used to arrange separate power lines and special sockets for the ...