Maintenance knowledge of 12HP (8.9kW) low temperature chiller
The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company’s product quality, improve production efficiency, but also extend the service life of the 12HP (8.9kW) low-temperature chiller by using the knowledge learned.

1. In the initial operation of the 12HP (8.9kW) low-temperature chiller, the oil level, oil return and oil cleanliness of the compressor should be observed frequently. If the oil is dirty or the oil level drops, it should be replaced or added in time to avoid poor lubrication and affect refrigeration. machine is running.
2. For air-cooled: the air-cooler should be cleaned frequently to maintain a good heat exchange state, and the condenser should be checked frequently for scaling problems, and the scale should be removed in time.
3. For water-cooled: Always check the turbidity of the cooling water, if the cooling water is too dirty, it needs to be replaced, whether the water pump is working normally, whether the valve switch is effective, whether the cooling water tower and the fan are normal.
4. For the air-cooled evaporator: it is necessary to check the defrosting situation frequently. Whether the defrosting is timely and effective will affect the cooling effect and cause the refrigeration system to return to liquid.
5. Always observe the compressor running status of the 12HP (8.9kW) low-temperature chiller, check its exhaust temperature, and pay special attention to the running status of the system when operating in a seasonal change, and adjust the liquid supply and condensing temperature of the system in time.
6. Carefully listen to the running sound of the compressor, cooling tower, water pump or condenser fan, find out and deal with it in time, and check the vibration of the compressor, exhaust pipe and water pump at the same time.
7. After 30 days of operation, the refrigerating oil and drying filter should be replaced once, and after half a year of operation (depending on the actual situation). For systems with higher cleanliness, the refrigeration oil and filter drier should be replaced after six months of operation.
Our LNEYA is a professional chiller manufacturer, our customers are located in Europe, America and Southeast Asia. For the 12HP (8.9kW) low temperature chiller, you can contact us if you have any questions.
Raccomandazioni correlate
-
How to choose reactor heating and cooling device?
916When the user selects the heating and cooling device of the reactor, if the heating and cooling device of the reactor is not well understood, it will not know how to start when selecting, so how to choose the heating and cooling of the reactor is ...
Visualizza i dettagli -
L'unità raffreddata ad aria da 300.000 kcal di LNEYA sulla tenuta dell'aria
1085Quando l'utente mette in funzione l'unità di raffreddamento ad aria da 300.000 kcal, deve controllare l'ermeticità dell'aria, perché l'ermeticità potrebbe far consumare all'unità di raffreddamento ad aria troppa energia. Per evitare che la temperatura si abbassi a lungo durante la ...
Visualizza i dettagli -
The ethylene glycol chiller solution is too cold and too hot
1040When the ethylene glycol chiller solutionis overheated and overcooled during operation, if you don't understand theseconditions well, you will not be able to operate the equipment well.The supercooling phenomenon of the solutionof the glycol ch...
Visualizza i dettagli -
Electric Vehicle Motor Test Cooling System Chiller Instructions
1286With the continuous development of new energy vehicles, Chiller, the electric motor motor test cooling system, is also developing. The new chiller for motor testing of new energy vehicles can adaptively adjust the chiller according to the dynamic ...
Visualizza i dettagli