Small hot and cold shock test box use note
Small thermal shock test chamber is non-explosion-proof product (explosion-proof needs to be customized), please do not use it in the environment with flammable or explosive gas. In order to avoid small thermal shock, the test box is faulty, please provide rated voltage. Power supply within range. To prevent electric shock or malfunction and malfunction, do not turn on the power before installation and wiring are completed. Please try not to open the test box door during work. If it is opened at high temperature, it may cause burns to the operator. Opening at low temperature may cause frostbite to the staff and may cause the evaporator to freeze and affect the cooling effect. If it must be opened, please do a certain amount of protection work, prohibit unauthorized disassembly, processing, modification or repair of small thermal shock test box, otherwise there will be abnormal action, electric shock or fire.
The danger of disaster.
The vents of the small thermal shock test chamber should be kept open to avoid malfunction, abnormal operation, reduced life and fire. If the machine is damaged or deformed when unpacking, please do not use it. Be careful not to let dust, wire ends, iron filings or other things enter during machine installation, otherwise malfunction or malfunction will occur. Wiring must be correct and must be grounded. Failure to ground may result in electric shock, malfunction or malfunction, abnormal display or large measurement error.

The small thermal shock test box needs to check the terminal screws and the fixing frame regularly. Please do not use it in loose condition. During operation, the power input terminal cover must be installed on the terminal block to prevent electric shock. When the instrument is in operation, the safety should be fully considered before the operation of modifying the settings, signal output, starting, stopping, etc., and the wrong operation may cause damage or malfunction of the working equipment. Please wipe the meter with a dry cloth. Do not use alcohol, gasoline or other organic solvents. Do not splash water on the meter. If the meter is immersed in water, stop using it immediately, otherwise there is danger of electric leakage, electric shock or fire. Internal parts have a certain life span. For continuous and safe use of the instrument, please perform regular maintenance and maintenance. When disposing of this product, please dispose of it according to industrial waste.
We should pay attention to the use of attention points, so as to avoid the failure of the small thermal shock test chamber during use and improve the efficiency in operation.
Raccomandazioni correlate
-
Core Maintenance Points of Ten High and Low Temperature Test Chamber Manufacturers
1037According to many years’ production experience of high and low temperature test chamber in Wuxi Guanya, it is found that many users are not very familiar with the maintenance of high and low temperature test chamber. As one of the top ten manufact...
Visualizza i dettagli -
Precautions for the use of LNEYA chillers in industrial processes
11811. Installation (check the machine for damage, choose the right location for installation and maintenance) 2. The location of the installation unit must be the floor, mounting mat or foundation, the level is within 6.4mm, and can withstand the wor...
Visualizza i dettagli -
Miniature high-pressure reaction kettle refrigeration heating temperature control system
987The miniature high-pressure reaction kettle refrigeration heating temperature control system is designed with a gas feed unit, a liquid feed unit, a reaction unit and a collection unit. The raw material gas and raw material liquid are mixed and pr...
Visualizza i dettagli -
Ultra-low temperature freezing manufacturer analyzes the cause of blockage in refrigeration system
1272With the continuous development of technology, ultra-low temperature refrigeration technology is also constantly developing, and manufacturers are also increasing. Of course, the technology of different manufacturers is different. Once the refrige...
Visualizza i dettagli