Maintenance of vacuum pump for fully enclosed heating and cooling circulator
Each accessory in the fully enclosed heating and cooling circulator constitutes the entire refrigeration heating and temperature control system. The performance of the pump is also very important. How to make the maintenance of the pump?
For the fully enclosed heating and cooling circulator circuit, the electronic circuit and the mechanical rotating part are routinely inspected and repaired. Pay attention to whether the various indicators are damaged or deteriorated, and regular maintenance is required.

Do the vacuum pump working status and the registration of each working time, record the cause of the instrument failure and the troubleshooting method in time to ensure that the vacuum pump works in a better state.
Keep the vacuum pump symmetrically balanced. If the sample tube placed in the pump chamber is unbalanced, it will cause the circulating water vacuum pump to shift. After the shutdown is reset, check if the vacuum pump is normal.
Before use, please pay attention to check the rotor for corrosion points and fine cracks. The rotor that has been corroded or cracked is forbidden to use. If the rotor exceeds the shelf life, it should be checked frequently to ensure personal safety.
The fully enclosed heating and cooling circulator vacuum pump cover door bolts should be checked frequently and kept flexible to prevent forced opening or closing. When an abnormality occurs, it is necessary to repair and replace it in time. Common faults, usually pay attention to observation, and promptly eliminate the solution.
After use, the water in the pump chamber should be dried, and a small amount of neutral grease should be applied to the cone surface of the motor shaft periodically. Remove the rotor from the circulating water vacuum pump for a long time, wipe it clean and place it in a dry place.
LNEYA specializes in the production of fully enclosed heating and cooling circulators, refrigeration and heating circulators, TCU, ultra-low temperature freezer, freezer and other equipment of good quality, laughing and welcoming visitors come to negotiate!
Raccomandazioni correlate
-
Manutenzione del condensatore nei refrigeratori a bassa temperatura
894Negli ultimi anni, con il miglioramento del livello di produzione industriale cinese, molti macchinari e attrezzature industriali professionali forniscono un aiuto maggiore per le diverse produzioni industriali. Come attrezzatura di refrigerazione industriale molto pratica, l...
Visualizza i dettagli -
Effetto della temperatura sulle reazioni della sintesi chimica organica
1277La sintesi organica è un fenomeno chimico comune in chimica. La temperatura ha un'influenza importante su di essa durante l'intero processo di sintesi. Con l'aumento della temperatura, la reazione che assorbe calore si accelera, determinando un cambiamento significativo...
Visualizza i dettagli -
Matters Needing Attention in Replacing Refrigerant Oil of the Screw Chiller Factory
1048The refrigerant oil in the screw chiller factory needs regular inspection and replacement. We all know that different grades of refrigerant oil cannot be mixed together, otherwise it will cause abnormal or strike conditions of the screw chiller fa...
Visualizza i dettagli -
How to use multiple reactors for high and low temperature integrated machine
1364Multiple reactors high and low temperature integrated machine temperature control system will be connected with thermal conductive synthetic oil and power supply before use, and multiple reactor high and low temperature integrated machine temperat...
Visualizza i dettagli