Apparecchiature del sistema di controllo della temperatura di refrigerazione del laboratorio
Lab water chillers, as the name implies, are mainly used in colleges and universities, scientific research and laboratories. Specially for the cooling of small laboratory equipment such as spectrometer, mass spectrometer, viscometer, rotation, fermentation device, a rotary evaporation apparatus, etc. to make them work under the suitable working temperature.
Could them only be used in this way? In fact, the lab water chillers are also called small chillers. It can also be used for cooling with small instruments or small power equipment. For example:
1. Vacuum pump and medical equipment: molecular pump, diffusion pump, cooling blanket, X-ray machine, nuclear magnetic resonance, accelerator;
2. Industrial equipment and other: laser equipment, vacuum coating equipment, biological pharmacy, mold, machine tool, vacuum furnace, welding machine, reaction kettle.
3. Matched small vacuum pumps, such as molecular pumps, oil and gas recovery pumps, small roots pumps, rotary disc pumps, slide valve pumps, etc. It has the advantages of convenient connection, simple operation, stable temperature, and saving water and electricity, providing a stable temperature environment for the vacuum equipment, and providing the operating efficiency of the equipment.

Laboratory chillers belong to LNEYA refrigeration temperature control system equipment.
Advantages and functions of temperature control system of refrigeration:Temperature range from 120 to 350, performance superior, unique, high – precision, intelligent temperature control.High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
Raccomandazioni correlate
-
Vacuum coating high and low temperature circulation system operation method
1227In many current chemical experiments, the vacuum coating high and low temperature circulation system can be used, making the high and low temperature refrigeration heating system supporting the vacuum coating system, and the operation is more effi...
Visualizza i dettagli -
Closed cycle heating system temperature deviation description
893If the temperature deviation occurs in the closed cycle heating system during use, it is necessary to check to see if there is any problem in each link, and solve the problem in time. In the steady state, the closed loop heating system displays th...
Visualizza i dettagli -
How to Deal with Fault of Conpressor after Cold Plate Freezer for Sale?
883In the operation of the cryogenic refrigerator refrigeration system, once the compressor fault occurs, it will affect the operation of the cryogenic refrigerator. So what are the faults that affect the compressor? How do clients settle it if the c...
Visualizza i dettagli -
Tips on how to save energy for enterprises using industrial chiller
977Nowadays, energy conservation has been advocated, and power consumption has always been a concern for everyone. Everyone knows that industrial equipment consumes electricity. For many chemical material manufacturing enterprises, the pressure of th...
Visualizza i dettagli