Descrizione del fabbisogno di olio di refrigerazione dell'unità di recupero dei gas di scarico organici
The organic waste gas recovery device is slightly different for different gases. The LNEYA organic waste gas recovery device and the vocs gas condensation recovery device are operated by the principles of condensation and adsorption. The refrigeration oil is also important, then the refrigeration oil has What is the requirement?
The cloud point of the frozen oil of the organic waste gas recovery device refers to the temperature at which the paraffin is precipitated in the frozen oil and the lubricating oil becomes turbid when the temperature is lowered to a certain value. The cloud point of the refrigeration oil used in the device should be lower than the evaporation temperature of the refrigerant, otherwise it will cause the throttle valve to block or affect the heat transfer performance.
The temperature at which the frozen oil is cooled under experimental conditions to stop flowing is referred to as the freezing point. The freezing point of the frozen oil used in the organic waste gas recovery device should be as low as possible (such as R22 compressor, the refrigeration oil should be below -55 °C), otherwise it will affect the flow of the refrigerant and increase the flow resistance, resulting in poor heat transfer. as a result of.

An important parameter in the characteristics of the oil viscosity of the refrigerating oil. Different refrigerants should be used to select different refrigerating oils. If the viscosity of the frozen oil is too large, the mechanical friction power, friction heat and starting torque will increase. On the other hand, if the viscosity is too small, the desired oil film cannot be formed between the moving parts, so that the desired lubrication and cooling effect cannot be achieved.
The flash point of a frozen oil is the temperature at which the lubricating oil is heated to the point where it is ignited when it comes into contact with the flame. The flash point of the frozen oil used in the organic waste gas recovery device must be 15 to 30 ° C higher than the exhaust gas temperature to avoid burning and coking of the lubricating oil. Organic waste gas recovery devices such as chemical stability and oxidation resistance, moisture and mechanical impurities, and insulation properties.
As far as the current environmental protection trend is concerned, if the company has organic waste gas, it is recommended to buy an organic waste gas recovery device for gas treatment as soon as possible to avoid troubles.
Raccomandazioni correlate
-
Structural Characteristics of Industrial Recirculating Chiller
835In the chemical reaction, there are strict requirements for the reaction temperature. It is necessary to raise the temperature to an appropriate temperature to carry out the chemical reaction smoothly. After the reaction, the temperature in the re...
Visualizza i dettagli -
Guidelines for Safe Use and Maintenance of Ultra-Low Temperature Freezer
9631. It is necessary to understand the influence of environment on refrigerators.2. Familiar with basic operation, maintenance and maintenance knowledge3. Develop good habitsLet the refrigerator breathe freely;Let the air around the refrigerator ci...
Visualizza i dettagli -
Commissioning of circulating water chiller equipment in the chemical industry
1006After completing the installation of circulating water chillers in the chemical industry, certain debugging needs to be carried out in the early stage of operation. Only through careful debugging can we find out whether there are hidden troubles i...
Visualizza i dettagli -
Detailed introduction of the motor control cooling system Chiller
1271With the continuous development of new energy vehicles, the motor control cooling system Chiller is also under continuous development. The new energy vehicle motor test special chiller can adaptively adjust the cooling capacity of the chiller acco...
Visualizza i dettagli