Energy-efficient high and low temperature circulation box description
With the efficient development of the pharmaceutical and chemical industry, environmental pollution is also the subject of more attention. To this end, LNEYA actively responds to environmental protection, produces energy-efficient and high-temperature circulating boxes, and saves enterprise costs as much as possible.
The high and low temperature circulation box group reduces the condensation temperature under the premise of evaporation temperature. In order to meet the safety and production requirements of the equipment, the evaporation temperature is lowered to reduce the condensation temperature, so as to ensure the cooling water efficiency and increase the transformation. Adjust the reasonable operation of the chiller equipment. When the equipment is safely operated, the cooling unit operates at 70%-80% load ratio and runs at 100% load, and the power consumption per unit of cooling capacity is smaller. In this way, it is necessary to combine the operation of the water pump and the cooling tower.

Prevent and reduce pipe fouling to improve the heat exchange efficiency of the condenser and evaporator. Replenish water If the water treatment is not good, calcium carbonate and magnesium carbonate produced by the heating of calcium bicarbonate and magnesium bicarbonate will deposit on the pipeline. Decreasing the thermal conductivity, affecting the heat exchange efficiency of the condenser and the evaporator, and greatly increasing the electricity cost of the equipment. In addition to the water treatment technology, it is also possible to use the pipeline automatic cleaning equipment for pipeline cleaning. The high-low temperature cycle box group refrigerator frequency conversion device adjusts the speed of the centrifugal refrigerator compressor. After the low-pressure refrigerant passes through the centrifuge, the pressure rises. The higher the speed of the centrifuge, the higher the pressure rises. In actual operation, most of the equipment is running at a non-full load. A fixed-speed centrifuge wastes energy when the equipment is running at a small load. The variable frequency centrifugal chiller can automatically adjust the compressor speed according to the change of the load, and the energy saving space is relatively large.
These operating instructions can help the high and low temperature circulation box to be more energy efficient and use as much energy consumption as possible.
Raccomandazioni correlate
-
Several elements of the operation of -20 degree industrial cryogenic chiller
1313-20 degree industrial cryogenic chiller is a refrigeration equipment that provides low temperature chilled water. It is often used in production enterprises, such as chemical companies, pharmaceutical companies and other production processes, to p...
Visualizza i dettagli -
Nota di attenzione per il debug del sistema di raffreddamento a circolazione chiusa
1136Il sistema di raffreddamento a circolazione chiusa deve prestare attenzione ad alcuni problemi comuni durante la messa in servizio. Fare un buon lavoro di debug. I produttori di LNEYA ricordano agli utenti che solo quando sono pronti a lavorare possono essere sottoposti a un debug migliore. La preparazione...
Visualizza i dettagli -
Trouble shooting method for refrigeration device of air-cooled chiller chemical reaction kettle
1019If air enters into the air-cooled chiller refrigeration unit system of the chemical reaction kettle, the impact will be many. Enter the air circulation system first, the pressure will rise, the heat dissipation effect of the condenser will also be...
Visualizza i dettagli -
Principio del sistema di controllo della temperatura TCU
1401Area di utilizzo: può essere utilizzata in diverse aree a prova di esplosione L'unità di controllo della temperatura (TCU) è utilizzata principalmente per il riscaldamento e il controllo della temperatura del reattore nei processi di chimica fine, chimico-farmaceutici e biofarmaceutici. È in grado di realizzare...
Visualizza i dettagli