How to Choose Chiller and Injection Moulding Machine?
A. First way:
The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees.
The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force injection machine, and the temperature can be controlled at 10-15 degrees.
The 1HP water-cooled chiller can be equipped with 120 tons mould-locking force injection moulding machine, and the temperature can be controlled at 15-20 degrees.
(The matching of air-cooled chiller is 0.8 times that of water-cooled chiller, that is, the temperature of injection moulding machine of 1HP air-cooled chiller with 64 tons of clamping force is controlled at 5-10 degrees.)
B. The second way:
1HP water-cooled chiller can be equipped with injection moulding machine with a single injection volume of 10 QZ, and the temperature can be controlled at 5-10 degrees.
Injection Mold Quantity 1QZ=28.5g
The above formulas are the results summarized by the classics. In addition to the above formulas, the salesman should filter the actual situation and select the appropriate chiller.
C. Matching of chillers and cooling towers:
According to experience, 1HP chiller needs a cooling tower of 1.2 tons to take away the heat generated by the chiller.
We are a top chiller manufacturer. Welcome to buy our products.
Raccomandazioni correlate
-
Istruzioni per l'uso della camera di prova a bassa temperatura
1079La camera di prova a bassa temperatura è un'apparecchiatura di prova necessaria nei settori dell'aviazione, dell'automobile, degli elettrodomestici, della ricerca scientifica e in altri campi. Viene utilizzata per testare e determinare i parametri e le prestazioni di apparecchiature elettriche, elettroniche e...
Visualizza i dettagli -
Laboratory dedicated chiller pressure description
1031The laboratory-specific chiller is one of the more popular equipments in the mechanical equipment industry. For this reason, the relevant pressure instructions have been specially compiled to help you better understand the laboratory-specific chil...
Visualizza i dettagli -
The Instruction Of Ultra Low Temperature Freezer Minus 80 Degrees
1159The machine must be tested before usage (or before it is energized again) in the following conditions: when ultra low temperature freezer is first used in ultra low temperature freezer minus 80 degrees, or after the ultra low temperature freezer i...
Visualizza i dettagli -
Punti di installazione delle criopompe nei frigoriferi criogenici
1221Nella costruzione di un frigorifero criogenico, la criopompa è un elemento indispensabile. Il produttore di congelatori a bassa temperatura LNEYA indica a tutti che la criopompa deve essere utilizzata in base ai requisiti al momento della sua installazione.