Low-temperature coolant circulation pump used with rotary evaporator
The chemical and pharmaceutical fields are the largest end consumer markets for cryogenic coolant circulation pumps. With the increasing demand for low-temperature coolant circulation pumps in this market, the application of cryogenic pumps in the chemical industry is becoming more mature. As a laboratory instrument, cryogenic coolant circulation pumps are indispensable to the laboratory field. It plays an important role in chemical, pharmaceutical and chemical research.

The low-temperature coolant circulation pump can directly cool test tubes, reaction flasks, etc. to carry out chemical reactions at low temperatures, and carry out low-temperature storage of chemicals and biological products. It can also be used in conjunction with rotary evaporators, vacuum freeze-drying boxes, circulating water-type multi-purpose vacuum pumps, etc.
One low temperature coolant circulation pump with two rotary evaporation laboratory cases Note points:
When in use, the actual temperature should not be lower than the minimum temperature. If water is used as the circulating solution, the water inlet pipe cannot be higher than 60 degrees Celsius, but when using absolute ethanol, the water inlet can not be higher than 10 degrees Celsius.

Lneya low-temperature coolant circulation pump adopts international brand compressor, which has small volume and high efficiency. Single compressor can achieve -152°C temperature control. The shell material is cold-rolled steel plate, and the circulating pump with pressure ≤6bar can be customized to make the liquid storage larger capacity according to the needs. Exclusive self-cascade supercooling refrigeration technology, in order to save water resources, can use ethylene glycol-water mixture for circulating refrigeration, strict circulation pipeline design, prevent circulating water pollution, extend the circulating water use time; -125 ° C ~-20 °C Wide temperature range; adjustment unit 0.1 degree. Ambient temperature monitoring function is provided to prevent damage to the system when the ambient temperature is too high.
Raccomandazioni correlate
-
Parti di apparecchiature aerospaziali Istruzioni per la risoluzione dei problemi di refrigerazione del congelatore di prova criogenico
1235Cooling water inlet temperature is too low Ultra-low temperature freezer for ultra-low temperature testing of aerospace equipment components As the temperature of the cooling water decreases, the compressor discharge pressure, exhaust temperature,...
Visualizza i dettagli -
Instructions for Manufacturers of Cold Plate Freezer [-5 to -150 Degrees of Refrigeration]
1067There are various manufacturers of Low Temperature low temperature cold plate freezer. It is widely used in glass reactor, metal reactor and bioreactor to control temperature and temperature.Using Range of Low Temperature Cold Plate FreezerMediu...
Visualizza i dettagli -
Come risolvere il fenomeno della brinatura del compressore del congelatore da 50p?
1006Il congelatore 50p è utilizzato nel trattamento industriale a freddo, ma se le prestazioni non sono buone, può portare al lavoro industriale, soprattutto se è difettoso, è più difficile da risolvere. Pertanto, è meglio capire i vari difetti del congelatore 50p...
Visualizza i dettagli -
How to choose the optimal chiller solution?
953Choosing a water chiller is like finding a "target" for an enterprise's production equipment. It must not only be "like-minded", but also "be well-matched". The one that suits you is the best. If the choice is not good, either the cooling effect ...
Visualizza i dettagli