The WTD vacuum chiller has a temperature control accuracy of up to ±0.3℃ and a temperature range of -70℃ to 300℃, giving you a more accurate, stable and efficient temperature control experience.
più basso
Il più alto
Precisione del controllo della temperatura
Mezzo e materiale
Contact LNEYA sales engineer
for catalog or price.
Modello | WTD-120M | WTD-255 | WTD-455 | WTD-755 | WTD-275V | |
Intervallo di temperatura | -5°C~120°C | -25°C~200°C | -45°C~250°C | -70°C~200°C | -20°C~300°C | |
Temp resolution | 0.1K | |||||
Control model | Controllore adattativo PID | |||||
Capacità di riscaldamento | 2kW | 5,5kW | 5,5kW | 5,5kW | 7,5kW | |
Cooling capacity kW | 300°C | 7,5kW | ||||
200°C | 5,5kW | 5,5kW | 5,5kW | 7,5kW | ||
100°C | 1,5kW | 5,5kW | 5 kW | 5 kW | 7,5kW | |
20°C | 1 kW | 5,5kW | 5 kW | 5 kW | 5,5kW | |
-15°C | 2,5kW | 4 kW | 4 kW | 2,5kW | ||
-35°C | 1,5kW | 3 kW | ||||
-60°C | 1,1 kW | |||||
Pompa di circolazione max | 7L/min 2,5bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | |
Temp sensor | PT100 | PT100 | PT100 | PT100 | PT100 | |
Cooling way | Raffreddato ad aria | Air cooled+water cooled | ||||
Heating-conduction medium | Synthetic heat conducting oil | |||||
Potenza 380V 50HZ | 220V 3.1kW | 9.5kW MAX | 10kW MAX | 12kW MAX | 15kW MAX |
Floor space
The WTD recirculating chiller heater uses a plate heat exchanger with a compact structure and a small footprint, which is suitable for use in places with limited space. The bottom is equipped with 4 casters, which is convenient for you to move the position at any time according to your needs.
Core accessories
The accessories of the WTD industrial chiller heater are basically internationally renowned brands. For example, the compressor uses Secop, Emerson Copeland and French Tecumseh, etc.; the dry filter uses Danfoss; the contactor/circuit breaker uses Schneider.
Cannabis extraction
Cannabinoids and other active ingredients contained in cannabis are important for medical treatment, but a key factor in cannabis extraction is temperature control in processes such as extraction, distillation, crystallization, and solvent recovery. Only by accurately and stably controlling the temperature environment with the help of chiller heater units can we help improve the efficiency of extraction and the quality of products.
Prodotti farmaceutici
In the pharmaceutical process, researchers need to use laboratory thermostats to change the temperature environment, understand the stability of drugs at different temperatures, and observe the changes in their efficacy and activity.
30.000 + clienti.
20+ paesi.
CE, SGS, certificazione ISO.
24/7 solutions.
Oltre 15 anni di esperienza.
Test di qualità.
Non riuscite a trovare un refrigeratore adatto? O non sapete come scegliere un refrigeratore? Contattateci ora per ottenere dettagli e prezzi dei refrigeratori.
Contatto LNEYA
Inviateci la vostra richiesta e vi contatteremo entro 24 ore.