FL-WS 5℃~30℃
High power chiller- Cooling Power89kW~1724kW
- Power Supply3N/380V/50Hz
- Weight850kG~7900kG
Product data download
Product Description
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
2.Due to continuous updating of product technology, the above data is subject to change without prior notice.
3.In addition to the listed product models, our company can customize non-standard units according to customer requirements.
This series of equipment is suitable for various production process cold sources in the fields of chemical industry, medicine, machinery, etc. It can provide -110℃~30℃ refrigeration medium, and can be used as ice storage, low-temperature air supply and other process cold sources required by production processes. Our company can specially design the unit according to the requirements of users. The unit adopts advanced semi-enclosed screw compressor, which is low-carbon, energy-saving and environmentally friendly; it has good performance and low noise, and can run without trouble for more than 100,000 hours; the temperature control can be step-by-step energy regulation or stepless energy regulation control. According to the heat load required by the specific production, the outlet water temperature of the refrigerant is used as the control point, and the control center sends instructions to adjust the movement of the energy regulation slide valve to adjust the load of the compressor unit to achieve a real energy-saving effect.
Model FL- | 100WS | 200WS | 300WS | 400WS | 510WS | 660WS | 1700WD | |
Cooling capacity 5℃ |
kW | 103 | 203 | 280 | 370 | 506 | 678 | 1724 |
Kcal/hr*10³ | 89 | 175 | 241 | 318 | 435 | 583 | 1483 | |
±0.5 | ||||||||
Power Supply | 3N/380V/50HZ | |||||||
Cooling input power | 23 | 46 | 62 | 81 | 110 | 146 | 362 | |
Compressor | Form | Semi-hermetic screw compressor | ||||||
Energy control range | 0~25~37.5~50~62.5~75~87.5~100(12.5% segment control) | |||||||
Chilled Water | Form | Dry, flooded or falling film heat exchangers | ||||||
Chilled water volume T/H | 20 | 35 | 50 | 65 | 86 | 115 | 280 | |
Water pressure drop KPa | 40~80 | |||||||
Take over specifications | DN65 | DN100 | DN125 | |||||
Cooling water | Form | Horizontal shell and tube | ||||||
Cooling water volume T/H | 22 | 45 | 60 | 80 | 110 | 140 | 360 | |
Water pressure drop KPa | 40~80 | |||||||
Take over specifications | DN65 | DN100 | DN125 | |||||
Protective Device | High and low voltage protection, anti-icing, heat release protection, safety valve, overload protection, phase loss, reverse phase, undervoltage, overvoltage, water flow protection, etc. | |||||||
Refrigerant | Filling amount Kg | 22 | 44 | 55 | 58 | 80 | 115 | 235 |
Dimensions | Length mm | 250 | 264 | 313 | 314 | 314 | 328 | 397 |
Width mm | 85 | 90 | 110 | 110 | 110 | 110 | 160 | |
High mm | 130 | 143 | 157 | 178 | 180 | 202 | 225 | |
Weight | 850 | 1270 | 1740 | 2480 | 2870 | 3400 | 7900 | |
Operating Weight | 900 | 1420 | 1890 | 2580 | 3120 | 3700 | 8600 |
You may also be interested in these products
LT -45℃~30℃
Industrial/Laboratory Air ChillerCOOLING TEMP -45℃~30℃Configuration DetailsProductDescriptionCooling MethodData Communication InterfaceAPPLICATION SCENARIOProduct Applicationsrecommend products LOW TEMPERATURE COOLING C…
LT -60℃~-20℃
Low Temperature Chiller/CirculatorLOW TEMP. REFRIGERATION CIRCULATORConfiguration Details1. Rated test conditions: dry bulb temperature 20℃; wet bulb temperature 16℃. Inlet water temperature 20℃; outlet water temperature 25℃.2. The data in this t…
LT -80℃~-20℃
Industrial Air Chiller UnitLOW TEMP. REFRIGERATION CIRCULATORProductDescriptionCooling MethodData Communication InterfaceAPPLICATION SCENARIOProduct ApplicationsRecommend products It can guarantee 24-hour continuous operation …
LT 10℃~30℃
Product data downloadConfiguration DetailsProductDescriptionCooling MethodData Communication InterfaceAPPLICATION SCENARIOProduct ApplicationsRecommend products Saving water resources & circulating cooling …
loading…