Wuxi Guanya Refrigeration Technology co., ltd

Water-cooled Chillers/Cryogenic Chillers/Refrigerated Chillers/Ultra-low Temperature Chillers

Application Fields:




Low temperature reaction in chemical, pharmaceutical, biochemical and other industries.



Single fluid low-temperature refrigerator has a refrigeration temperature range of - 10 ℃ ~ - 115 ℃. It is fast, safe and reliable. It is used for liquid rapid refrigeration and is widely used in petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical, military and other high-tech industries.


WORKING PRINCIPLE


The whole system is a fully closed system, and there is no water absorption during low temperature operation, which ensures the purity of the cold heat transfer medium, prevents ice crystals, and improves the life of the heat transfer fluid.


The direct-cooling ultra-low temperature freezer developed by LNEYA adopts international brand compressors and single-compressor automatic cascade refrigeration technology. It can be cooled to minus 120°C within 3 minutes, and the cooling speed is fast, safe and reliable.


PRODUCT VIDEOS



Ultra-low Temperature Chiller Can Be Either Air-Cooled Chiller Or Water-Cooled Chiller. The Choice Of Air Cooling Or Water Cooling Depends On Your On-Site Process Conditions And Requirements, You Can Explain To Us At The First Time, So As To Better Choose Model.

Advantages of Ultra-low Temperature Chillers(Water-cooled Chillers)

1.Adopt secondary subcooling technology, rapid cooling and low cooling temperature;
2.Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK. Bitzer, Copeland, Handbell, fusheng; Plate heat exchanger, Small volume, High efficiency;

3.Top imported cold controller; Generator cooling water circuit uses intermediate heat exchanger, improve system reliability and safety.


BASIC STRUCTURE OF CHILLERs

Industrial water chiller consists of compressor, condenser, evaporator, expansion valve and other accessories.
Compressor: in the industrial water chiller system, the compressor is the power to ensure refrigeration. The compressor is used to increase the pressure of the refrigerant in the system and make the refrigerant circulate in the refrigeration system to achieve the purpose of refrigeration.
Condenser: high temperature and high pressure Freon of the refrigeration system enters the condenser after coming out of the compressor, releases a lot of heat to the cooling medium, and then is cooled and liquefied.
Evaporator: when the Freon liquid of the refrigeration system enters the expansion valve for throttling and is sent to the evaporator, it belongs to the vaporization process. At this time, it needs to absorb a lot of heat to gradually reduce the valence and mass temperature to achieve the effect of refrigeration and cooling.
Expansion valve: in the refrigerant system flow chart of the industrial water chiller, we found that there is a small part between the outlet of the condenser and the inlet of the evaporator, which is called thermal expansion valve. It is a throttling and depressurizing part to reduce the condensation pressure of the refrigerant to the evaporation pressure. Therefore, its role in the refrigeration system is essential. It is connected with the refrigeration compressor, evaporator, condenser It is also called the four components of the refrigeration system.
Other accessories: including drying filter and high and low pressure controller. The drying filter is non detachable. The internal structure adopts molecular sieve structure, which can remove a small amount of impurities and water in the pipeline, so as to purify the system. The high and low pressure controller plays a protective role in the refrigeration system.

Related News
Related Products
  • SLJ -110℃~-150℃

    SLJ -110℃~-150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • LT -45℃~30℃

    LT -45℃~30℃

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N;view
  • IC Test Cooling Chiller -45℃~250℃

    IC Test Cooling Chiller -45℃~250℃

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • Flash EMMC Thermal Head  -85℃~200℃

    Flash EMMC Thermal Head -85℃~200℃

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view
products
Contact US
Tel: + 86 18751545184
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat